CC BY 4.0 · Eur J Dent 2024; 18(03): 796-807
DOI: 10.1055/s-0043-1776335
Original Article

Shear Bond Strength of Simulated Single-Retainer Resin-Bonded Bridges Made of Four CAD/CAM Materials for Maxillary Lateral Incisor Agenesis Rehabilitation

1   UNIPRO - Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS-CESPU), Gandra, Portugal
2   Conservative Dentistry, Department of Dental Sciences, University Institute of Health Sciences (IUCS(IUCS-CESPU), Gandra, Portugal
,
João Mário Calheiros-Lobo
3   Dental Prosthetist, Private Prosthesis Laboratory, São Mamede Infesta, Portugal
,
Ricardo Carbas
4   Department of Mechanical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
5   INEGI - Institute of Science and Innovation in Mechanical and Industrial Engineering, University of Porto, Porto, Portugal
,
Lucas F. M. da Silva
4   Department of Mechanical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
5   INEGI - Institute of Science and Innovation in Mechanical and Industrial Engineering, University of Porto, Porto, Portugal
,
Teresa Pinho
1   UNIPRO - Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS-CESPU), Gandra, Portugal
6   Institute for Molecular and Cell Biology (IBMC), Institute of Innovation and Investigation in Health (i3S), University of Porto, 4200-135 Porto, Portugal
› Author Affiliations
Funding This research was funded by CESPU, CRL (Grant number: AlignAgen-GI2-CESPU-2022).
 

Abstract

Objectives Maxillary lateral incisor agenesis (MLIA), treated orthodontically by space opening, requires complimentary aesthetic rehabilitation. Resin-bonded bridges (RBBs) can be equated as interim rehabilitation until skeletal maturity is achieved to place an implant-supported crown or as definitive rehabilitation in case of financial restrictions or implant contraindications. Scientific evidence of the best material must be confirmed in specific clinical situations. Computer-aided design and computer-aided manufacturing (CAD/CAM) materials are promising versatile restorative options. This study aimed to identify a straightforward material to deliver interim or definitive RBBs for nonprepared tooth replacement in MLIA.

Materials and Methods Single-retainer RBB made from CAD/CAM ceramic blocks (Vita Enamic [ENA], Suprinity [SUP], and zirconia [Y-ZPT]) and a three-dimensional (3D) printed material (acrylonitrile butadiene styrene [ABS]) were evaluated by shear bond strength (SBS) and mode of failure, after adherence to an artificial tooth with RelyX Ultimate used in a three-step adhesive strategy.

Statistical Analysis The load to fracture (N) was recorded, and the mean shear stress (MPa) was calculated with standard deviations (SD) for each group and compared between materials using boxplot graphics. One-way analysis of variance (ANOVA) followed by the Tukey–Kramer post hoc test was used to compare the differences (α = 0.05). A meta-analysis focusing on CAD/CAM materials evaluated the magnitude of the difference between groups based on differences in means and effect sizes (α = 0.05; 95% confidence interval [CI]; Z-value = 1.96). Failure mode was determined by microscopic observation and correlated with the maximum load to fracture of the specimen.

Results The mean ± SD SBS values were ENA (24.24 ± 9.05 MPa) < ABS (24.01 ± 1.94 MPa) < SUP (29.17 ± 4.78 MPa) < Y-ZPT (37.43 ± 12.20 MPa). The failure modes were mainly adhesive for Y-ZPT, cohesive for SUP and ENA, and cohesive with plastic deformation for ABS.

Conclusion Vita Enamic, Suprinity, Y-ZPT zirconia, and 3D-printed ABS RBBs are optional materials for rehabilitating MLIA. The option for each material is conditioned to estimate the time of use and necessity of removal for orthodontic or surgical techniques.


#

Introduction

Maxillary lateral incisor agenesis (MLIA) is a prevalent nonsyndromic congenital tooth agenesis, often bilateral,[1] [2] and associated with reduced maxillary sagittal growth and altered relative lower incisor position,[3] making functional postorthodontic stabilization pertinent. Its challenging treatment has valuable aesthetic options, including orthodontic space opening followed by lateral incisor prosthetic replacement or space closure with canine mesialization complemented by tooth remodeling.[4] [5] Single-retainer resin-bonded bridges (RBBs) are aesthetic, minimally invasive restorative, and reversible options for interim or definitive rehabilitation in cases of space-opening procedures,[4] [5] mainly in clinical situations with ongoing maxillofacial growth due to periodontal and aesthetic factors.[6] [7] [8]

Computer-aided design and computer-aided manufacturing (CAD/CAM) materials are versatile for aesthetic restorations, but clinical evidence-based data concerning their success and durability still need to be explored.[9] [10] Available for digital workflow, these industrial materials evolve faster than the data returned from high-quality clinical trials,[11] leading clinicians and dental prosthetics to doubts about optimizing the available options.[12] Furthermore, in vitro studies usually integrate equipment unavailable in clinical settings, and only some experimental protocols can be transposed directly from the laboratory to the clinical context,[11] making pertinent experimental designs that simulate clinical situations and settings and uses standardized base adherends to avoid the heterogeneity of the natural teeth.

CAD/CAM monolithic ceramics are mainly polycrystalline, glass-matrix, indirect composites, and hybrid ceramics.[13] [14] The polycrystalline ceramic Vita YZ HT (Y-ZPT) (VITA Zahnfabrik, Bad Säckingen, Germany) is a 5 mol% yttria-stabilized zirconia and a standard for new generations by its physical and mechanical characteristics (opaque white appearance and high flexural strength/1,200–1,500 MPa).[15] [16]

Combining a low flexural modulus with a high flexural strength (150–160 MPa), the hybrid ceramic Vita Enamic (ENA; VITA Zahnfabrik) is a polymer-infiltrated ceramic network[13] capable of elastic deformation before failure, with a mechanical behavior similar to that of a human tooth.[17] Despite the low stiffness,[18] it is quite stable under extreme acid exposure, and cyclic loading does not affect its properties.[19] Its unique polymer-based microstructure is essential for the micromechanical bond and the performance of the adhesive interface[20] [21] due to a decreased crack propagation.[22] High translucency, fluorescence, and opalescence are the main characteristics of Vita Suprinity (SUP; VITA Zahnfabrik), according to the manufacturer. This homogeneous fine-grained glass-ceramic enriched with zirconia has a consistently high load capacity (flexural strength in crystallized state, 420 MPa). Delivered precrystallized, it is an interesting material for anterior RBBs because of its aesthetics, biocompatibility, mechanical properties, and more straightforward adhesive protocol.[13] [14] [23] Clinical data remain scarce, often controversial, and limited to short-term observational periods.[24] [25]

Medical ABS (acrylonitrile butadiene styrene; Smart Materials 3D, Jaén, Spain; ISO 10993–1) is a lightweight bisphenol A (BPA) free thermoplastic polymer that attains tensile strengths ranging from 15 to 38 MPa with an elastic modulus of 1,300 to 1,800 MPa. Produced via fused deposition, its mechanical behavior depends on processing temperatures, printing parameters, proportions of monomers in the ABS structure, and force orientation during testing.[26]

The quality of an adhesive joint is determined by the bond quality at different interfaces and the adhesive strength of the restorative materials, as in the case of RBBs. The interfaces between the dental tissue and the adhesive cement and the connection between the cement and the surface of the restorative material play essential roles.[27] In this process, adhesion and cohesion[23] [28] are involved, with the first between the substrates and the second within each substrate.

Characterization of the interface before adhesion, during function, and after failure is helpful in adhesive joint research and remains a significant challenge[28] because a specific adhesive protocol is required for each paired material to obtain the highest bond strength.[11] [29]

Advances in adhesive dentistry and technology expanded the use of RBBs with alternative preparation designs and materials.[30] To best predict the future clinical performance of CAD/CAM materials to fabricate RBBs, similar designs and fabrication procedures following real dental laboratory and clinical procedures should be chosen.[31] Meanwhile, it is accepted that the adhesive strength of zirconia depends on particle abrasion and primers or adhesives containing 10-methacryloxydecyl dihydrogen phosphate (MDP).[32] [33]

This study evaluated single-retainer RBBs manufactured similarly to those for clinical application in MLIA. Three CAD/CAM monolithic ceramics and one additive-manufactured CAD/CAM material adhered to an artificial tooth with dual-cured cement were assessed for shear bond strength (SBS) and fracture mode. The null hypothesis was that no differences would be observed between the SBS of the tested materials in the tested RBB model.


#

Materials and Methods

The materials used in this study are listed in [Table 1]. Polycrystalline zirconia (Y-ZPT) was used as control material. Based on previous research,[21] a photoinitiated dual-cured adhesive cement, RelyX Ultimate (RU; 3M ESPE, Seefeld, Germany), used in a three-step adhesive strategy, was used to adhere the experimental RBBs to an artificial tooth.

Table 1

General description of materials used in this study, their compositions, and manufacturers

Material

Name

Code

Composition

Manufacturer

CAD-CAM monolithic ceramics

Vita Enamic

ENA

86% feldspar ceramic: SiO2 58–63%, Al2O3 20–23%, Na2O9–11%, K2O4–6% by weight, 14% polymer by weight: TEGDMA, UDMA

VITA Zahnfabrik, Bad Säckingen, Germany

Vita Suprinity

SUP

Zirconium oxide 8–12%, silicon dioxide 56–64%, lithium oxide 15–21%, various > 10% by weight

VITA Zahnfabrik

Vita 5Y-TPZ Color

Y-ZPT

Zirconia reinforced with 5% yttria

VITA Zahnfabrik

CAD-CAM 3D-printed material

Medical ABS

ABS

Acrylonitrile butadiene styrene

Smart Materials 3D, Jaén, Spain

Resin-matrix composite cement

RelyX Ultimate

RU

MDP phosphate monomer, dimethacrylate resins, HEMA, Vitrebond copolymer filler, ethanol, water, initiators, silane

3M Oral Care, St. Paul, MN, United States

Etching agent

Porcelain Etch Gel

PEG

Hydrofluoric acid 9.6%

Pulpdent, Watertown, MA, United States

Ceramic primer

Monobond Plus

MB

50–100% ethanol, disulfide methacrylate, ≤2.5% phosphoric acid dimethacrylate, ≤2.5% 3-trimethoxysilylpropyl methacrylate

Ivoclar Vivadent AG, Schaan, Liechtenstein

Adhesive system

Scotchbond Universal adhesive

SB-U

MDP, Bis-GMA, phosphate monomer, dimethacrylate resins, HEMA, methacrylate-modified polyalkenoic acid copolymer, filler, ethanol, water, initiators, silane-treated silica

3M Oral Care

Hydrophobic resin

Heliobond

HEL

HEMA, Bis-GMA, UDMA, initiators (camphorquinone and benzoyl peroxide), fillers (silica, glass particles), and solvents (ethanol and acetone)

Ivoclar Vivadent AG

Artificial teeth

Frasaco tooth

FRA

Melamine-based composition

Frasaco GmbH, Tettnang, Germany

Abbreviations: HEMA, hydroxyethylmethacrylate, MDP, 10-methacryloyloxydecyl dihydrogen phosphate; TEGDMA, UDMA, urethane dimethacrylate; triethylene glycol dimethacrylate.


Acquisition and Processing of Digital Images

Digital images of a Frasaco A3 Adult Typodont (Frasaco GmbH, Tettnang, Germany) were acquired using a Medit i700 intraoral scanner (MEDIT Corp., Seoul, Republic of Korea) and processed using the software Medit Link v3.0.6 Build 286, and Medit Scan for Clinics v1.9.6 Revision 268 (MEDIT Corp.; [Fig. 1]).

Zoom Image
Fig. 1 Images acquired using an intraoral scanner. (A) Reference data from both maxillaries in frontal view, (B) occlusion data, (C) reference maxilla in occlusal view, (D) maxilla simulating a lateral incisor agenesis, (E) the same in detail, (F) a view from palatal, and (G) maxilla simulating a lateral incisor agenesis in occlusal view.

[Fig. 2] shows the main steps of the data processing of the digital workflow (3Shape CAD/CAM software, Copenhagen, Denmark), focusing on material resistance and occlusal contacts. The connector area was set at 6.6 mm2, limited by the vestibular, incisal, and gingival parameters. The minimum thickness for the retainer wing was 0.5 mm. This procedure was repeated according to the manufacturer's instructions for each monolithic CAD/CAM ceramic.

Zoom Image
Fig. 2 Stereolithography (STL) images uploaded to 3Shape software. (A,B) Reference data from both maxillaries in frontal view (with and without the lateral incisor) for the calibration of the occlusal plane. (C,D,d,δ) Details of the planned resin-bonded bridge (RBB). (F,G,g,λ) Details of the planned RBB to be milled from an ENA block. (H) The digital case mounted in the digital articulator.

#

Single-Retainer Bridge Production

After the digital design, monolithic RBBs were fabricated using a CAD-CAM inLab milling machine (Dentsply/Sirona, Charlotte, NC, United States), following the manufacturer's laboratory procedures. By fused deposition, Medical ABS RBBs were constructed using a Pro2 3D printer (Raise3D, Irvine, CA, United States).


#

Cementation of the Resin-Bonded Bridges

Frasaco right central incisors (Frasaco GmbH) were used as adherends. As in a clinical context, the superficial glossy surface was removed using a coarse diamond bur simulating the intraoral removal of the aprismatic or fluoridated enamel, followed by surface conditioning for 60 seconds with 5% hydrofluoric acid. The prepared teeth were shuffled to ensure randomization and operator blinding. A 20-second oil-free air/water spray removed the produced debris. [Table 2] lists the adhesive protocols used for each type of material. RelyX Ultimate cement was applied using a three-step adhesive strategy and allowed to self-cure for 7 minutes after 5 seconds of photoinitiation (Elipar S10 curing unit, 1,200 mW/cm2; 3M ESPE) through the buccal and palatal sides of the Frasaco tooth. All the steps were performed by the same restorative dentist (single operator) with greater than 30 years of clinical experience.

Table 2

Materials used for adherends' surface treatment and adhesion

Cement

Substrate

Surface treatment (Frasaco tooth)

Surface treatment (RBB)

Adhesive system

RelyX Ultimate

ABS

5% hydrofluoric acid

Heliobond

Scotchbond Universal

Enamic

5% hydrofluoric acid

9.6% hydrofluoric acid 60 s

Suprinity

5% hydrofluoric acid

9.6% hydrofluoric acid 20 s

Y-ZPT

5% hydrofluoric acid

Al2O3 sandblasting

Abbreviations: ABS, acrylonitrile butadiene styrene; RBB, resin-bonded bridge.



#

Mechanical Testing of Resin-Bonded Bridges

The four groups of RBB specimens (Y-ZPT, SUP, ENA, and ABS) were mechanically assessed under load displacement of 0.2 mm/min (Instron–Universal tensile machine). [Fig. 3A] and [B] shows details of the shear-bond test settings. Load-displacement curves were recorded during the mechanical test. The maximum load in the test was used to identify the experimental RBB that supported the highest shear stress, and the highest shear stress supported by the adherend before cohesive failure.

Zoom Image
Fig. 3 (A) Scheme of the components designed for testing (1, block stabilizer; 2, base adherend incorporated in acrylic resin block; 3, load cell and piston; 4, stationary base; 5, resin-bonded bridge [RBB] to be tested). (B) Photograph of the shear bonding test with block stabilized on the stationary base and RBB tooth positioned for shear bond strength (SBS) with the piston positioned 2 mm away from the incisal border.

#

Data Analysis

The load to fracture (N) and mean shear stress (MPa) with standard deviations (SD) registered for each group were compared using boxplot graphics. One-way analysis of variance (ANOVA) followed by the Tukey–Kramer post hoc test was used to compare the differences (α = 0.05). A meta-analysis focusing on CAD/CAM materials evaluated the magnitude of the difference between groups based on differences in means and effect sizes (α = 0.05; 95% confidence interval [CI]; Z-value = 1.96) using a software program (Stata v18.0; StataCorp, College Station, TX, United States). The failure mode was determined by microscopic observation and correlated with the maximum load to fracture of the specimen.


#
#

Results

The mechanical behavior, SBS, and failure mode results are shown in [Fig. 4A] and [Table 3]. Despite having a lower performance, the ABS was more consistent, and observing the curve during loading suggested a marked plastic deformation before failure. Box plots in [Fig. 4B] allows rapid visualization of the different mechanical performance between materials. The compared mean ± standard deviation values for the adhesive strength were ENA (24.24 ± 9.05 MPa) < ABS (24.01 ± 1.94 MPa) < SUP (29.17 ± 4.78 MPa) < Y-ZPT (37.43 ± 12.20 MPa).

Zoom Image
Fig. 4 (A) Specimens behavior under load, from the control group (Y-ZPT), Suprinity, Enamic, and ABS groups. (B) Box plots of shear strength (MPa) of resin-bonded bridges (RBBs) by type of material. (C) Forest plot summarizing the effect size of the Computer-aided design and computer-aided manufacturing (CAD/CAM) materials and (D) comparative procedure between groups after analysis of variance (ANOVA).
Table 3

Compression strength and mode of failure by group and sample

Groups

Compression strength

Mode of failure

N

MPa

Sample

AD

C_A

C_RBB

RelyX Ultimate

Medical ABS

158.45

24.01

1

x

x

Medical ABS

176.22

26.70

2

x

x

Medical ABS

140.36

21.27

3

x

x

Medical ABS

158.28

23.98

4

x

x

Medical ABS

162.60

24.64

5

x

x

Failure load

Shear strength

Mean (N)

SD (N)

Mean (MPa)

SD (MPa)

159.18

12.82

24.12

1.94

AD

C_A

C_RBB

Vita Enamic

170.52

25.84

1

x

x

Vita Enamic

61.09

9.26

2

x

x

Vita Enamic

158.45

24.01

3

x

x

Vita Enamic

191.42

29.00

4

x

Vita Enamic

218.30

33.08

5

x

x

Failure load

Shear Strength

Mean (N)

SD (N)

Mean (MPa)

SD (MPa)

159.96

59.75

24.24

9.05

AD

C_A

C_RBB

Vita Suprinity

171.75

26.02

1

x

x

Vita Suprinity

172.16

26.08

2

x

x

Vita Suprinity

221.43

33.55

3

x

x

Vita Suprinity

165.31

25.05

4

x

x

Vita Suprinity

232.03

35.15

5

x

x

Failure load

Shear strength

Mean (N)

SD (N)

Mean (MPa)

SD (MPa)

192.54

31.56

29.17

4.78

AD

C_A

C_RBB

Vita Y-ZPT

271.40

41.12

1

x

x

Vita Y-ZPT

375.01

56.82

2

x

x

Vita Y-ZPT

224.90

34.08

3

FTF

FTF

Vita Y-ZPT

180.4

27.33

4

x

Vita Y-ZPT

183.49

27.80

5

x

Failure load

Shear Strength

Mean (N)

SD (N)

Mean (MPa)

SD (MPa)

247.04

80.53

37.43

12.20

Abbreviations: AD, adhesive failure; C_A, adherend cohesive failure; C_RBB, bridge cohesive failure; FTF, Frasaco tooth fracture; SD, standard deviation.


[Fig. 4C] shows that the mechanical performance of Y-ZPT was significantly better than that of the others (p < 0.001). [Fig. 4D] shows the results of the compared differences (α = 0.05), highlighting the superior shear strength of Y-ZPT, particularly with ENA and ABS. The failure modes were mainly adhesive for Y-ZPT, cohesive in the RBB for SUP and ENA, and cohesive with plastic deformation of the RBB for ABS ([Figs. 5] and [6], and [Table 3]).

Zoom Image
Fig. 5 Resin-bonded bridges (RBBs) after testing. (A) Enamic, (B) Y-ZPT, (C) Suprinity, and (D) ABS groups, with different mechanical behavior after shear load.
Zoom Image
Fig. 6 Details of fractured resin-bonded bridges (RBBs) and more frequent failure modes by material type. (A) ENA, adhesive interproximal and cohesive in retainer. (B) Y-ZPT, adhesive, with RBB integrity. (C) SUP, cohesive in Frasaco tooth and retainer. (D) ABS, adhesive in interproximal, cohesive with plastic deformation in RBB (no RBB tooth loss occurred).

#

Discussion

The null hypothesis that no differences would be found in the SBS among the tested materials in the tested RBB model was rejected because significant differences existed (p < 0.01). Y-ZPT (control) was the most rigid material in this experimental model, consistent with the literature. The ABS, ENA, and SUP groups exhibited consistent mechanical performances.

When speaking about the longevity of rehabilitative treatment, one implicitly thinks of definitive rehabilitation. However, when treating a case of MLIA, rehabilitation must often be temporary and adaptable. This is the case of orthodontic space opening, in which success is reflected in the progressive diastema between the central incisor and the canine tooth. In these specific cases, zirconia RBB is not advisable because it is too resistant to be removed repeatedly without damaging the supporting tooth and has a laborious adhesive technique that hinders the addition of resin-matrix-based materials. Thus, the possibility of fabricating RBBs with materials that are easier to handle, can be replaced at low cost, or are easier to remove from the supporting tooth led us to look for alternatives, mainly focusing on managing orthodontic treatments using aligners that would benefit from a straightforward handling prosthesis.

Adhesion between CAD/CAM materials and teeth substrates depends on adhesive systems[34] and chemical interactions that occur between functional monomers and tooth components,[35] which in turn depend on the properties of the materials, which are crucial to the success of adhesive restorations.[22] In this experimental setting, RelyX Ultimate cement was used based on recent research[21] [23] by its adhesive efficiency and versatility when paired with Y-ZPT, ENA, and SUP ceramics. Also, adhesive protocols followed literature guidelines.[11] [13] [27] [33] [34] Nothing was found in the literature about the adhesive protocol for Medical ABS. Considering the chemical composition and ease of handling of the material, an old and well-known hydrophobic resin (Heliobond, Ivoclar Vivadent AG, Schaan, Liechtenstein) was selected to simplify the adhesive protocol bearing in mind the possibility of using Medical ABS RBBs as an easily exchangeable interim prosthesis. These adhesive systems evidenced differences between materials' mechanical behavior and allowed them to attain the maximal cohesive strength of the adherend. Therefore, should not have biased the study results.

Regarding CAD/CAM materials, the results showed that the mechanical behavior of RBBs depends on the type of material. Besides that, anterior RBBs have their clinical survival dependent on the mechanical resistance of the connector, which is related to its thickness and bonding surface area. These two variables are especially critical in RBBs replacing lateral incisors due to occlusogingival and vestibular-palatal anatomic restrictions related to the available interocclusal space for the restorative material. About this subject, the literature found is mainly focused on zirconia-veneered frameworks and the posterior region,[36] and a single retainer with a connector diameter of 16 mm2 in the anterior region and 20 mm2 in the posterior region has been suggested with the assumption that periodontal hygiene might be a concern.[37] In the present study, the connector area was set at 6.6 mm2 and the bonding surface area at 42 mm2 following more realistic dimensions suggested in the literature[38] (>4.5 and > 35 mm2, respectively) estimated for the Y-ZPT RBB (control) and consequently for the other materials tested. A recent study[39] using finite elements proposes a volume of 9.04 mm3 instead of an area for an anterior connector planned for lithium disilicate, a material less resistant than zirconia. In any case, there is evidence that an increased cross-sectional thickness of the connector is desirable.[40] Replacing a lateral incisor originates a relatively short cantilever length, which favors the clinical survival of the restoration.[41]

Using Frasaco teeth as adherends was very useful because they have a standardized composition and anatomy, allowing the elimination of bias originating from biological factors or different macroanatomies of the palatal face of a natural incisor, which can occur if natural teeth have been used, as only slight asperization was intended, as in a minimally invasive approach.[8] A practical comparison between the materials used to manufacture single-retainer RBBs without inherent ethical restrictions was also possible. Despite the expected low shear strength of Frasaco teeth based on a preliminary study, their resistance was sufficient to demonstrate differences in the mechanical behavior of the RBBs, as exclusive adhesive failure was verified only for RBBs manufactured with zirconia, a material with high toughness.

Transposing the findings to a clinical situation, it can be suggested that using an RBB made of ENA or SUP as their mode of failure led to the complete loss of the pontic, the removal of the retainer, and the manufacture of a new restoration would be necessary. In the case of Y-ZPT, loss of adhesion without RBB structural changes, a fact in line with the primary failure reported in the literature for this material,[33] [37] would allow for an immediate new adhesive procedure. As for the ABS RBB, no information was found in the literature. This study suggests that its plastic deformation would allow the patient to have an appointment with the dentist before the pontic is lost, avoiding being toothless, an advantage over the other tested materials.

Concerning Medical ABS, its low melting point (105°C) makes it ideal for in-office equipment. It must be highlighted that if manufactured by extrusion-based fused deposition modeling (FDM), the orientation of the appendages influences its mechanical characteristics. Therefore, a careful design contemplating this aspect is necessary for an excellent final mechanical performance.[42] The significant benefits of FDM are low cost, rapid prototyping, and simplicity of procedure.[43] Complex geometries with a high concentration of stress should be avoided. However, if not possible, fabric from powder (SLS—selective laser sintering) should be preferred because the unused powder fills the gaps between the filaments. Still, this procedure makes the Medical ABS RBB much more expensive, increases postprocessing time, and requires extra equipment, such as powder removal stations.[26] Reducing the size of the extruder nozzle diameter and the thickness of the layers reduces the water absorption properties and increases the tensile and flexural strength of the specimens.[43]

One cannot propose RBB as an option to rehabilitate the space of the MLIA without reflecting on occlusal function. Scientific literature focusing on occlusal efforts at the anterior level of the maxilla was not found, leading to a more embracing discussion. A study focusing on the maximum bite force (MBF) refers to a value of approximately 80 N (20% higher in bruxists) in individuals aged 22 to 48 years.[44] It varies with malocclusion, sex (higher in males), and age (increase until young adult age), decreasing significantly with vertical and transverse craniofacial and dental discrepancies, and with old age.[45] [46] Patients with normal sagittal occlusion are expected to have more molar bite force than patients with malocclusions, with a magnitude two to three times greater in the molar region than in the anterior region.[47] A recent systematic analysis showed that the MBF ranged from 246.22 to 489.35 N and 5.69 to 16.1 kg in children and adolescents, respectively.[48] If a contact area of 1 mm2 is assumed, respective values of 246 to 489 MPa and 0.56 to 158 MPa would be obtained. However, if the results from T-scan measurements of the occlusal contact area in MBF[49] are considered, revealing a mean value of 155 mm2 for healthy young adults, the conversion would be to 0.3 to 3 MPa/mm2 of contact area. Generally, a single-retainer RBB design should be preferred whenever canine guidance is present. However, with relatively short clinical crowns of the abutment teeth and limited bonding surface, a two-lingual retainer design might be preferred if a group function articulation is present.[8] [25]

Considering patients treated for MLIA by space opening reflection must be made because occlusal loads are higher than expected for the average patient whenever hypodivergence is present.[50] However, at the end of orthodontic treatment, an equilibrated occlusal function is mandatory, with a dispersed distribution of occlusal forces, thus theoretically reducing the adhesive stress on RBBs in the anterior maxilla.

Extrapolating the results of this study to clinical situations, Y-ZPT RBBs are the most suitable for MLIA rehabilitation, a finding consistent with the literature and that validates the choice of this material as the control material used in this study. However, more research is needed for newer zirconias with higher yttria contents because of their reduced toughness by almost half. Not testing them, instead of the tougher third-generation material, is a limitation of this study because newer compositions with higher yttria content, while improved aesthetically, have lower mechanical performance and are more susceptible to breakage.[15] [16] Thickness, composition, microstructure, and cementing agent are crucial for the performance of the resistant tetragonal phase of monolithic zirconia,[51] advising caution when extrapolating results from research focusing on the longevity of older materials.[12] Although scarce, available randomized clinical trials (RCTs) using newer compositions have promising results.[38] Well-designed RCTs with large sample sizes are still needed to achieve more accurate results about the clinical success rate of different RBB designs in the anterior region,[24] [25] knowing from the start that lower cantilever length and higher occlusocervical thickness significantly increases load to fracture values.[40] One well-controlled RCT,[38] some clinical studies,[8] [52] [53] and some systematic reviews[54] [55] found in the literature revealed high survival rates and good clinical performance for the single-retainer zirconia RBBs from 18 months up to 15 years, with reported clinical results comparable or even better than those of the conventional fixed prosthesis and implant-supported crowns.[8] [37] [41] [53]

Still, patients with MLIA situations are frequently adolescents with ongoing maxillofacial growth,[2] and despite there is no sufficient evidence to either indicate or contradict the usage of dental implants in this age group,[7] its implantation requires positional modifications to attend periodontal and aesthetic factors, and they should be considered only under particular circumstances.[6] [7] If infraocclusion of the replaced tooth occurs over time, new prosthetic restoration, new orthodontic treatment, or distraction osteogenesis may be necessary,[7] along with carefully planned rehabilitation treatment that should contemplate interim rehabilitation.

Whenever the option is short-term interim rehabilitation (orthodontic appliance removal or adaptation, periodontal remodeling or maturation, a short period between the end of orthodontic treatment and implant-supported crown placement, or even during the time of osseointegration of the implant), any other material is feasible and preferable because of more straightforward adhesive protocols, removal, or marginal adaptation for tissue management, if desired. For that purpose, printed ABS RBB is an interesting material. It can be fabricated quickly on the chairside at a low cost.[26] [43] It requires only a hydrophobic resin for surface treatment, allowing an easy and quick cementation technique for minimally invasive rehabilitation. Further research using this or similar materials should be conducted in the future.

This study used a specific RBB design with a retainer on the palatal side of the central incisor. This design could raise constraints in cases of minimal interocclusal space due to sagittal or vertical discrepancies that may coexist in MLIA cases. Alternative approaches, such as employing a single retainer adhered to the buccal side of the central incisor or canine tooth, should be considered because of the thin dimensions of the retainer, which would not invade the buccal profile of the supporting tooth and a more straightforward cementation technique than the palatal one.


#

Conclusion

RBBs made of Vita Enamic, Suprinity, Y-ZPT zirconia, or 3D-printed ABS can support physiological occlusal loads of the anterior maxilla. They can be used to rehabilitate MLIA in clinical situations. As long as the adhesive protocol is technically well executed, zirconia is the material of choice for definitive rehabilitation, as, due to its mechanical resistance, occasional adhesive failure without structural loss allows for immediate new cementation. If needed, ABS, ENA, and SUP are more suitable for interim RBBs because of the advantage of easier removal and in-mouth adaptation. The option for each material depends on the estimated time for use (temporary or permanent rehabilitation) and the necessity of removal for orthodontic or surgical techniques.


#
#

Conflict of Interest

None declared.

Data Availability Statement

The data presented in this study are available in the article.


Authors' Contribution

M.J.C.L. and R.C. conceptualized the study. M.J.C.L. was responsible for the methodology, formal analysis, writing—original draft preparation, and visualization. M.J.C.L. and J.M.C.L were responsible for the software and resources. Validation was done by M.J.C.L., R.C., and L.F.M.S. Investigation was done by M.J.C.L., J.M.C.L., and R.C. Data curation was done by R.C., while M.J.C.L. and L.F.M.S. contributed to writing, reviewing, and editing of the manuscript. T.P. was responsible for supervision, project administration, and fund acquisition. All the authors have read and agreed to the final version of the manuscript.


All authors contributed equally to this work.


  • References

  • 1 Lupinetti GM, Li P, Feagin K, MacDougall M, Lamani E. Non-syndromic hypodontia of maxillary lateral incisors and its association with other dental anomalies. Prog Orthod 2022; 23 (01) 53
  • 2 Pinho T, Pollmann C, Calheiros-Lobo MJ, Sousa A, Lemos C. Craniofacial repercussions in maxillary lateral incisors agenesis. Int Orthod 2011; 9 (03) 274-285
  • 3 Herrera-Atoche JR, Medina-Mazariegos CR, Zúñiga-Herrera ID. et al. Growth differences in patients with dental agenesis, how its location impacts facial morphology. J Dent Sci 2020; 15 (03) 336-344
  • 4 Calheiros-Lobo MJ, Calheiros-Lobo M, Pinho T. Esthetic perception of different clinical situations of maxillary lateral incisor agenesis according to populations with dental and non-dental backgrounds: a systematic review and meta-analysis. Dent J 2023; 11 (04) 105
  • 5 Abdulrahman NAM, Khalifa N, Alhajj MN. Dentists' preferences in the treatment of congenitally missing maxillary lateral incisors. Braz Dent Sci 2019; 22 (02) 243-251
  • 6 Bohner L, Hanisch M, Kleinheinz J, Jung S. Dental implants in growing patients: a systematic review. Br J Oral Maxillofac Surg 2019; 57 (05) 397-406
  • 7 Kamatham R, Avisa P, Vinnakota DN, Nuvvula S. Adverse effects of implants in children and adolescents: a systematic review. J Clin Pediatr Dent 2019; 43 (02) 69-77
  • 8 Zitzmann NU, Büren AV, Glenz F, Rohr N, Joda T, Zaugg LK. Clinical outcome of metal- and all-ceramic resin-bonded fixed dental prostheses. J Prosthodont Res 2021; 65 (02) 243-248
  • 9 Sulaiman TA. Materials in digital dentistry: a review. J Esthet Restor Dent 2020; 32 (02) 171-181
  • 10 Balasubramaniam GR. Predictability of resin bonded bridges: a systematic review. Br Dent J 2017; 222 (11) 849-858
  • 11 Calheiros-Lobo MJ, Carbas R, da Silva LFM, Pinho T. Impact of in vitro findings on clinical protocols for the adhesion of CAD-CAM blocks: a systematic integrative review and meta-analysis. J Prosthet Dent 2022;S0022-3913(22)00551-0
  • 12 Güth JF, Stawarczyk B, Edelhoff D, Liebermann A. Zirconia and its novel compositions: what do clinicians need to know?. Quintessence Int 2019; 50 (07) 512-520
  • 13 Awad MM, Alqahtani H, Al-Mudahi A, Murayshed MS, Alrahlah A, Bhandi SH. Adhesive bonding to computer-aided design/ computer-aided manufacturing esthetic dental materials: an overview. J Contemp Dent Pract 2017; 18 (07) 622-626
  • 14 Skorulska A, Piszko P, Rybak Z, Szymonowicz M, Dobrzyński M. Review on polymer, ceramic and composite materials for CAD/CAM indirect restorations in dentistry-application, mechanical characteristics and comparison. Materials (Basel) 2021; 14 (07) 1592
  • 15 Fathy SM, Al-Zordk W. E Grawish M, V Swain M, Flexural strength and translucency characterization of aesthetic monolithic zirconia and relevance to clinical indications: a systematic review. Dent Mater 2021; 37 (04) 711-730
  • 16 Zhang Y, Lawn BR. Evaluating dental zirconia. Dent Mater 2019; 35 (01) 15-23
  • 17 Palacios T, Tarancón S, Pastor JY. On the mechanical properties of hybrid dental materials for CAD/CAM restorations. Polymers (Basel) 2022; 14 (16) 3252
  • 18 Awada A, Nathanson D. Mechanical properties of resin-ceramic CAD/CAM restorative materials. J Prosthet Dent 2015; 114 (04) 587-593
  • 19 Egilmez F, Ergun G, Cekic-Nagas I, Vallittu PK, Lassila LVJ. Does artificial aging affect mechanical properties of CAD/CAM composite materials. J Prosthodont Res 2018; 62 (01) 65-74
  • 20 Eldafrawy M, Ebroin MG, Gailly PA, Nguyen JF, Sadoun MJ, Mainjot AK. Bonding to CAD-CAM composites: an interfacial fracture toughness approach. J Dent Res 2018; 97 (01) 60-67
  • 21 Calheiros-Lobo MJ, Calheiros-Lobo JM, Carbas R, da Silva LF, Pinho T. A polymer-infiltrated ceramic as base adherent in an experimental specimen model to test the shear bond strength of CAD-CAM monolithic ceramics used in resin-bonded dental bridges. Coatings 2023; 13 (07) 1218
  • 22 Silva PNFD, Martinelli-Lobo CM, Bottino MA, Melo RM, Valandro LF. Bond strength between a polymer-infiltrated ceramic network and a composite for repair: effect of several ceramic surface treatments. Braz Oral Res 2018; 32: e28
  • 23 Calheiros-Lobo MJ, Vieira T, Carbas R, da Silva LFM, Pinho T. Effectiveness of self-adhesive resin luting cement in CAD-CAM blocks-a systematic review and meta-analysis. Materials (Basel) 2023; 16 (08) 2996
  • 24 Zarone F, Ruggiero G, Leone R, Breschi L, Leuci S, Sorrentino R. Zirconia-reinforced lithium silicate (ZLS) mechanical and biological properties: a literature review. J Dent 2021; 109: 103661
  • 25 Tezulas E, Yildiz C, Evren B, Ozkan Y. Clinical procedures, designs, and survival rates of all-ceramic resin-bonded fixed dental prostheses in the anterior region: a systematic review. J Esthet Restor Dent 2018; 30 (04) 307-318
  • 26 Arefin AME, Khatri NR, Kulkarni N, Egan PF. Polymer 3D printing review: materials, process, and design strategies for medical applications. Polymers (Basel) 2021; 13 (09) 1499
  • 27 Raszewski Z, Brząkalski D, Derpeński Ł, Jałbrzykowski M, Przekop RE. Aspects and principles of material connections in restorative dentistry: a comprehensive review. Materials (Basel) 2022; 15 (20) 7131
  • 28 Marshall SJ, Bayne SC, Baier R, Tomsia AP, Marshall GW. A review of adhesion science. Dent Mater 2010; 26 (02) e11-e16
  • 29 Peumans M, Valjakova EB, De Munck J, Mishevska CB, Van Meerbeek B. Bonding effectiveness of luting composites to different CAD/CAM materials. J Adhes Dent 2016; 18 (04) 289-302
  • 30 Stylianou A, Liu PR, O'Neal SJ, Essig ME. Restoring congenitally missing maxillary lateral incisors using zirconia-based resin bonded prostheses. J Esthet Restor Dent 2016; 28 (01) 8-17
  • 31 Rekow ED, Silva NR, Coelho PG, Zhang Y, Guess P, Thompson VP. Performance of dental ceramics: challenges for improvements. J Dent Res 2011; 90 (08) 937-952
  • 32 Yoshida K. Effect of 10-methacryloyloxydecyl dihydrogen phosphate concentrations in primers on bonding resin cements to zirconia. J Prosthodont 2021; 30 (04) 356-362
  • 33 Quigley NP, Loo DSS, Choy C, Ha WN. Clinical efficacy of methods for bonding to zirconia: a systematic review. J Prosthet Dent 2021; 125 (02) 231-240
  • 34 Leung GK, Wong AW, Chu CH, Yu OY. Update on dental luting materials. Dent J 2022; 10 (11) 208
  • 35 Junior LR, Baroudi K, Barroso LS, Miranda ME, Vitti RP, Brandt WC. Bond strength of self-adhesive resin cement to dentin using different adhesion protocols. J Clin Exp Dent 2022; 14 (01) e35-e39
  • 36 Zarone F, Di Mauro MI, Ausiello P, Ruggiero G, Sorrentino R. Current status on lithium disilicate and zirconia: a narrative review. BMC Oral Health 2019; 19 (01) 134
  • 37 Alraheam IA, Ngoc CN, Wiesen CA, Donovan TE. Five-year success rate of resin-bonded fixed partial dentures: a systematic review. J Esthet Restor Dent 2019; 31 (01) 40-50
  • 38 Bilir H, Yuzbasioglu E, Sayar G, Kilinc DD, Bag HGG, Özcan M. CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: up to 40 months clinical results of a randomized-controlled pilot study. J Esthet Restor Dent 2022; 34 (07) 1122-1131
  • 39 Osman MLM, Lim TW, Chang HC, Ab Ghani AR, Tsoi JKH, Ab Ghani SM. Structural integrity of anterior ceramic resin-bonded fixed partial denture: a finite element analysis study. J Funct Biomater 2023; 14 (02) 108
  • 40 Alshahrani FA, Yilmaz B, Seidt JD, McGlumphy EA, Brantley WA. A load-to-fracture and strain analysis of monolithic zirconia cantilevered frameworks. J Prosthet Dent 2017; 118 (06) 752-758
  • 41 Kern M, Passia N, Sasse M, Yazigi C. Ten-year outcome of zirconia ceramic cantilever resin-bonded fixed dental prostheses and the influence of the reasons for missing incisors. J Dent 2017; 65: 51-55
  • 42 Keleş Ö, Blevins CW, Bowman KJ. Effect of build orientation on the mechanical reliability of 3D printed ABS. Rapid Prototyping J 2017; 23 (02) 320-328
  • 43 Saroia J, Wang Y, Wei Q. et al. A review on 3D printed matrix polymer composites: its potential and future challenges. Int J Adv Manuf Technol 2020; 106 (05) 1695-1721
  • 44 Dıraçoğlu D, Alptekin K, Çifter ED, Güçlü B, Karan A, Aksoy C. Relationship between maximal bite force and tooth wear in bruxist and non-bruxist individuals. Arch Oral Biol 2011; 56 (12) 1569-1575
  • 45 Kaur H, Singh N, Gupta H. et al. Effect of various malocclusion on maximal bite force: a systematic review. J Oral Biol Craniofac Res 2022; 12 (05) 687-693
  • 46 Shiga H, Komino M, Yokoyama M. et al. Relationship between age and occlusal force in adults with natural dentition. Odontology 2023; 111 (02) 487-492
  • 47 Hattori Y, Satoh C, Kunieda T, Endoh R, Hisamatsu H, Watanabe M. Bite forces and their resultants during forceful intercuspal clenching in humans. J Biomech 2009; 42 (10) 1533-1538
  • 48 Jayakumar P, FelsyPremila G, Muthu MS, Kirubakaran R, Panchanadikar N, Al-Qassar SS. Bite force of children and adolescents: a systematic review and meta-analysis. J Clin Pediatr Dent 2023; 47 (03) 39-53
  • 49 Ayuso-Montero R, Mariano-Hernandez Y, Khoury-Ribas L, Rovira-Lastra B, Willaert E, Martinez-Gomis J. Reliability and validity of T-scan and 3D intraoral scanning for measuring the occlusal contact area. J Prosthodont 2020; 29 (01) 19-25
  • 50 Turkistani KA, Alkayyal MA, Abbassy MA. et al. Comparison of occlusal bite force distribution in subjects with different occlusal characteristics. Cranio 2023; 41 (03) 204-211
  • 51 Arellano Moncayo AM, Peñate L, Arregui M, Giner-Tarrida L, Cedeño R. State of the art of different zirconia materials and their indications according to evidence-based clinical performance: a narrative review. Dent J 2023; 11 (01) 18
  • 52 Barwacz CA, Hernandez M, Husemann RH. Minimally invasive preparation and design of a cantilevered, all-ceramic, resin-bonded, fixed partial denture in the esthetic zone: a case report and descriptive review. J Esthet Restor Dent 2014; 26 (05) 314-323
  • 53 Kern M. Fifteen-year survival of anterior all-ceramic cantilever resin-bonded fixed dental prostheses. J Dent 2017; 56: 133-135
  • 54 Thoma DS, Sailer I, Ioannidis A, Zwahlen M, Makarov N, Pjetursson BE. A systematic review of the survival and complication rates of resin-bonded fixed dental prostheses after a mean observation period of at least 5 years. Clin Oral Implants Res 2017; 28 (11) 1421-1432
  • 55 Mourshed B, Samran A, Alfagih A, Samran A, Abdulrab S, Kern M. Anterior cantilever resin-bonded fixed dental prostheses: a review of the literature. J Prosthodont 2018; 27 (03) 266-275

Address for correspondence

Maria João Calheiros-Lobo, MD, DMD, MSc
IUCS-CESPU
Rua Central de Gandra 1317, 4585-116 Gandra PRD | Portugal
Teresa Pinho, DMD, PhD
IUCS-CESPU
Rua Central de Gandra 1317, 4585-116 Gandra PRD | Portugal

Publication History

Article published online:
29 December 2023

© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

  • References

  • 1 Lupinetti GM, Li P, Feagin K, MacDougall M, Lamani E. Non-syndromic hypodontia of maxillary lateral incisors and its association with other dental anomalies. Prog Orthod 2022; 23 (01) 53
  • 2 Pinho T, Pollmann C, Calheiros-Lobo MJ, Sousa A, Lemos C. Craniofacial repercussions in maxillary lateral incisors agenesis. Int Orthod 2011; 9 (03) 274-285
  • 3 Herrera-Atoche JR, Medina-Mazariegos CR, Zúñiga-Herrera ID. et al. Growth differences in patients with dental agenesis, how its location impacts facial morphology. J Dent Sci 2020; 15 (03) 336-344
  • 4 Calheiros-Lobo MJ, Calheiros-Lobo M, Pinho T. Esthetic perception of different clinical situations of maxillary lateral incisor agenesis according to populations with dental and non-dental backgrounds: a systematic review and meta-analysis. Dent J 2023; 11 (04) 105
  • 5 Abdulrahman NAM, Khalifa N, Alhajj MN. Dentists' preferences in the treatment of congenitally missing maxillary lateral incisors. Braz Dent Sci 2019; 22 (02) 243-251
  • 6 Bohner L, Hanisch M, Kleinheinz J, Jung S. Dental implants in growing patients: a systematic review. Br J Oral Maxillofac Surg 2019; 57 (05) 397-406
  • 7 Kamatham R, Avisa P, Vinnakota DN, Nuvvula S. Adverse effects of implants in children and adolescents: a systematic review. J Clin Pediatr Dent 2019; 43 (02) 69-77
  • 8 Zitzmann NU, Büren AV, Glenz F, Rohr N, Joda T, Zaugg LK. Clinical outcome of metal- and all-ceramic resin-bonded fixed dental prostheses. J Prosthodont Res 2021; 65 (02) 243-248
  • 9 Sulaiman TA. Materials in digital dentistry: a review. J Esthet Restor Dent 2020; 32 (02) 171-181
  • 10 Balasubramaniam GR. Predictability of resin bonded bridges: a systematic review. Br Dent J 2017; 222 (11) 849-858
  • 11 Calheiros-Lobo MJ, Carbas R, da Silva LFM, Pinho T. Impact of in vitro findings on clinical protocols for the adhesion of CAD-CAM blocks: a systematic integrative review and meta-analysis. J Prosthet Dent 2022;S0022-3913(22)00551-0
  • 12 Güth JF, Stawarczyk B, Edelhoff D, Liebermann A. Zirconia and its novel compositions: what do clinicians need to know?. Quintessence Int 2019; 50 (07) 512-520
  • 13 Awad MM, Alqahtani H, Al-Mudahi A, Murayshed MS, Alrahlah A, Bhandi SH. Adhesive bonding to computer-aided design/ computer-aided manufacturing esthetic dental materials: an overview. J Contemp Dent Pract 2017; 18 (07) 622-626
  • 14 Skorulska A, Piszko P, Rybak Z, Szymonowicz M, Dobrzyński M. Review on polymer, ceramic and composite materials for CAD/CAM indirect restorations in dentistry-application, mechanical characteristics and comparison. Materials (Basel) 2021; 14 (07) 1592
  • 15 Fathy SM, Al-Zordk W. E Grawish M, V Swain M, Flexural strength and translucency characterization of aesthetic monolithic zirconia and relevance to clinical indications: a systematic review. Dent Mater 2021; 37 (04) 711-730
  • 16 Zhang Y, Lawn BR. Evaluating dental zirconia. Dent Mater 2019; 35 (01) 15-23
  • 17 Palacios T, Tarancón S, Pastor JY. On the mechanical properties of hybrid dental materials for CAD/CAM restorations. Polymers (Basel) 2022; 14 (16) 3252
  • 18 Awada A, Nathanson D. Mechanical properties of resin-ceramic CAD/CAM restorative materials. J Prosthet Dent 2015; 114 (04) 587-593
  • 19 Egilmez F, Ergun G, Cekic-Nagas I, Vallittu PK, Lassila LVJ. Does artificial aging affect mechanical properties of CAD/CAM composite materials. J Prosthodont Res 2018; 62 (01) 65-74
  • 20 Eldafrawy M, Ebroin MG, Gailly PA, Nguyen JF, Sadoun MJ, Mainjot AK. Bonding to CAD-CAM composites: an interfacial fracture toughness approach. J Dent Res 2018; 97 (01) 60-67
  • 21 Calheiros-Lobo MJ, Calheiros-Lobo JM, Carbas R, da Silva LF, Pinho T. A polymer-infiltrated ceramic as base adherent in an experimental specimen model to test the shear bond strength of CAD-CAM monolithic ceramics used in resin-bonded dental bridges. Coatings 2023; 13 (07) 1218
  • 22 Silva PNFD, Martinelli-Lobo CM, Bottino MA, Melo RM, Valandro LF. Bond strength between a polymer-infiltrated ceramic network and a composite for repair: effect of several ceramic surface treatments. Braz Oral Res 2018; 32: e28
  • 23 Calheiros-Lobo MJ, Vieira T, Carbas R, da Silva LFM, Pinho T. Effectiveness of self-adhesive resin luting cement in CAD-CAM blocks-a systematic review and meta-analysis. Materials (Basel) 2023; 16 (08) 2996
  • 24 Zarone F, Ruggiero G, Leone R, Breschi L, Leuci S, Sorrentino R. Zirconia-reinforced lithium silicate (ZLS) mechanical and biological properties: a literature review. J Dent 2021; 109: 103661
  • 25 Tezulas E, Yildiz C, Evren B, Ozkan Y. Clinical procedures, designs, and survival rates of all-ceramic resin-bonded fixed dental prostheses in the anterior region: a systematic review. J Esthet Restor Dent 2018; 30 (04) 307-318
  • 26 Arefin AME, Khatri NR, Kulkarni N, Egan PF. Polymer 3D printing review: materials, process, and design strategies for medical applications. Polymers (Basel) 2021; 13 (09) 1499
  • 27 Raszewski Z, Brząkalski D, Derpeński Ł, Jałbrzykowski M, Przekop RE. Aspects and principles of material connections in restorative dentistry: a comprehensive review. Materials (Basel) 2022; 15 (20) 7131
  • 28 Marshall SJ, Bayne SC, Baier R, Tomsia AP, Marshall GW. A review of adhesion science. Dent Mater 2010; 26 (02) e11-e16
  • 29 Peumans M, Valjakova EB, De Munck J, Mishevska CB, Van Meerbeek B. Bonding effectiveness of luting composites to different CAD/CAM materials. J Adhes Dent 2016; 18 (04) 289-302
  • 30 Stylianou A, Liu PR, O'Neal SJ, Essig ME. Restoring congenitally missing maxillary lateral incisors using zirconia-based resin bonded prostheses. J Esthet Restor Dent 2016; 28 (01) 8-17
  • 31 Rekow ED, Silva NR, Coelho PG, Zhang Y, Guess P, Thompson VP. Performance of dental ceramics: challenges for improvements. J Dent Res 2011; 90 (08) 937-952
  • 32 Yoshida K. Effect of 10-methacryloyloxydecyl dihydrogen phosphate concentrations in primers on bonding resin cements to zirconia. J Prosthodont 2021; 30 (04) 356-362
  • 33 Quigley NP, Loo DSS, Choy C, Ha WN. Clinical efficacy of methods for bonding to zirconia: a systematic review. J Prosthet Dent 2021; 125 (02) 231-240
  • 34 Leung GK, Wong AW, Chu CH, Yu OY. Update on dental luting materials. Dent J 2022; 10 (11) 208
  • 35 Junior LR, Baroudi K, Barroso LS, Miranda ME, Vitti RP, Brandt WC. Bond strength of self-adhesive resin cement to dentin using different adhesion protocols. J Clin Exp Dent 2022; 14 (01) e35-e39
  • 36 Zarone F, Di Mauro MI, Ausiello P, Ruggiero G, Sorrentino R. Current status on lithium disilicate and zirconia: a narrative review. BMC Oral Health 2019; 19 (01) 134
  • 37 Alraheam IA, Ngoc CN, Wiesen CA, Donovan TE. Five-year success rate of resin-bonded fixed partial dentures: a systematic review. J Esthet Restor Dent 2019; 31 (01) 40-50
  • 38 Bilir H, Yuzbasioglu E, Sayar G, Kilinc DD, Bag HGG, Özcan M. CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: up to 40 months clinical results of a randomized-controlled pilot study. J Esthet Restor Dent 2022; 34 (07) 1122-1131
  • 39 Osman MLM, Lim TW, Chang HC, Ab Ghani AR, Tsoi JKH, Ab Ghani SM. Structural integrity of anterior ceramic resin-bonded fixed partial denture: a finite element analysis study. J Funct Biomater 2023; 14 (02) 108
  • 40 Alshahrani FA, Yilmaz B, Seidt JD, McGlumphy EA, Brantley WA. A load-to-fracture and strain analysis of monolithic zirconia cantilevered frameworks. J Prosthet Dent 2017; 118 (06) 752-758
  • 41 Kern M, Passia N, Sasse M, Yazigi C. Ten-year outcome of zirconia ceramic cantilever resin-bonded fixed dental prostheses and the influence of the reasons for missing incisors. J Dent 2017; 65: 51-55
  • 42 Keleş Ö, Blevins CW, Bowman KJ. Effect of build orientation on the mechanical reliability of 3D printed ABS. Rapid Prototyping J 2017; 23 (02) 320-328
  • 43 Saroia J, Wang Y, Wei Q. et al. A review on 3D printed matrix polymer composites: its potential and future challenges. Int J Adv Manuf Technol 2020; 106 (05) 1695-1721
  • 44 Dıraçoğlu D, Alptekin K, Çifter ED, Güçlü B, Karan A, Aksoy C. Relationship between maximal bite force and tooth wear in bruxist and non-bruxist individuals. Arch Oral Biol 2011; 56 (12) 1569-1575
  • 45 Kaur H, Singh N, Gupta H. et al. Effect of various malocclusion on maximal bite force: a systematic review. J Oral Biol Craniofac Res 2022; 12 (05) 687-693
  • 46 Shiga H, Komino M, Yokoyama M. et al. Relationship between age and occlusal force in adults with natural dentition. Odontology 2023; 111 (02) 487-492
  • 47 Hattori Y, Satoh C, Kunieda T, Endoh R, Hisamatsu H, Watanabe M. Bite forces and their resultants during forceful intercuspal clenching in humans. J Biomech 2009; 42 (10) 1533-1538
  • 48 Jayakumar P, FelsyPremila G, Muthu MS, Kirubakaran R, Panchanadikar N, Al-Qassar SS. Bite force of children and adolescents: a systematic review and meta-analysis. J Clin Pediatr Dent 2023; 47 (03) 39-53
  • 49 Ayuso-Montero R, Mariano-Hernandez Y, Khoury-Ribas L, Rovira-Lastra B, Willaert E, Martinez-Gomis J. Reliability and validity of T-scan and 3D intraoral scanning for measuring the occlusal contact area. J Prosthodont 2020; 29 (01) 19-25
  • 50 Turkistani KA, Alkayyal MA, Abbassy MA. et al. Comparison of occlusal bite force distribution in subjects with different occlusal characteristics. Cranio 2023; 41 (03) 204-211
  • 51 Arellano Moncayo AM, Peñate L, Arregui M, Giner-Tarrida L, Cedeño R. State of the art of different zirconia materials and their indications according to evidence-based clinical performance: a narrative review. Dent J 2023; 11 (01) 18
  • 52 Barwacz CA, Hernandez M, Husemann RH. Minimally invasive preparation and design of a cantilevered, all-ceramic, resin-bonded, fixed partial denture in the esthetic zone: a case report and descriptive review. J Esthet Restor Dent 2014; 26 (05) 314-323
  • 53 Kern M. Fifteen-year survival of anterior all-ceramic cantilever resin-bonded fixed dental prostheses. J Dent 2017; 56: 133-135
  • 54 Thoma DS, Sailer I, Ioannidis A, Zwahlen M, Makarov N, Pjetursson BE. A systematic review of the survival and complication rates of resin-bonded fixed dental prostheses after a mean observation period of at least 5 years. Clin Oral Implants Res 2017; 28 (11) 1421-1432
  • 55 Mourshed B, Samran A, Alfagih A, Samran A, Abdulrab S, Kern M. Anterior cantilever resin-bonded fixed dental prostheses: a review of the literature. J Prosthodont 2018; 27 (03) 266-275

Zoom Image
Fig. 1 Images acquired using an intraoral scanner. (A) Reference data from both maxillaries in frontal view, (B) occlusion data, (C) reference maxilla in occlusal view, (D) maxilla simulating a lateral incisor agenesis, (E) the same in detail, (F) a view from palatal, and (G) maxilla simulating a lateral incisor agenesis in occlusal view.
Zoom Image
Fig. 2 Stereolithography (STL) images uploaded to 3Shape software. (A,B) Reference data from both maxillaries in frontal view (with and without the lateral incisor) for the calibration of the occlusal plane. (C,D,d,δ) Details of the planned resin-bonded bridge (RBB). (F,G,g,λ) Details of the planned RBB to be milled from an ENA block. (H) The digital case mounted in the digital articulator.
Zoom Image
Fig. 3 (A) Scheme of the components designed for testing (1, block stabilizer; 2, base adherend incorporated in acrylic resin block; 3, load cell and piston; 4, stationary base; 5, resin-bonded bridge [RBB] to be tested). (B) Photograph of the shear bonding test with block stabilized on the stationary base and RBB tooth positioned for shear bond strength (SBS) with the piston positioned 2 mm away from the incisal border.
Zoom Image
Fig. 4 (A) Specimens behavior under load, from the control group (Y-ZPT), Suprinity, Enamic, and ABS groups. (B) Box plots of shear strength (MPa) of resin-bonded bridges (RBBs) by type of material. (C) Forest plot summarizing the effect size of the Computer-aided design and computer-aided manufacturing (CAD/CAM) materials and (D) comparative procedure between groups after analysis of variance (ANOVA).
Zoom Image
Fig. 5 Resin-bonded bridges (RBBs) after testing. (A) Enamic, (B) Y-ZPT, (C) Suprinity, and (D) ABS groups, with different mechanical behavior after shear load.
Zoom Image
Fig. 6 Details of fractured resin-bonded bridges (RBBs) and more frequent failure modes by material type. (A) ENA, adhesive interproximal and cohesive in retainer. (B) Y-ZPT, adhesive, with RBB integrity. (C) SUP, cohesive in Frasaco tooth and retainer. (D) ABS, adhesive in interproximal, cohesive with plastic deformation in RBB (no RBB tooth loss occurred).