Skull Base 2004; 14(3): 157-162
DOI: 10.1055/s-2004-832259
ORIGINAL ARTICLE

Copyright © 2004 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA.

Combined HRCT and MRI in the Detection of CSF Rhinorrhea

Badr Eldin Mostafa1 , Ahmed Khafagi1
  • 1Department of Otorhinolaryngology-Head and Neck Surgery, Ain-Shams University Faculty of Medicine, Cairo, Egypt
Further Information

Publication History

Publication Date:
24 August 2004 (online)

Cerebrospinal fluid (CSF) rhinorrhea is a potentially dangerous problem. Accurate preoperative localization of the site of leakage is mandatory. The standard diagnostic technique is computed tomography (CT) cisternography. Because of its related risks, however, various alternatives have been suggested. High-resolution CT (HRCT) provides good bony details, but fluid is poorly detected. In contrast, T2-weighted magnetic resonance imaging (MRI) shows CSF as a bright signal, but spatial resolution is poor as is the depiction of bony details. To overcome the shortcomings of both techniques, we superimposed the images obtained from each modality and used the result to plan surgical explorations. The sensitivity of HRCT was 88.25%. Fat-suppressed T2-weighted MRI detected a CSF-like density in 18 cases (90%) with a sensitivity of 88.88%. Superimposing the CTs and MRIs accurately localized the site of CSF leakage in 17 of 19 cases with a sensitivity of 89.74%. This finding compares favorably with the results of other techniques. We thus recommend this technique as the primary diagnostic method of choice for the investigation of patients with CSF rhinorrhea.

REFERENCES

  • 1 Shetty P G, Shroff M M, Fatterpekar G M, Sahani D V, Kirtane M V. A retrospective analysis of spontaneous sphenoid sinus fistula: MR and CT findings.  Am J Neuroradiol. 2000;  21 337-342
  • 2 Schmerber S, Boubagra K, Cuisnier O, Righini C, Reyt E. Methods of identification and localization of ethmoid and sphenoid osteomeningeal breaches.  Rev Laryngol Otol Rhinol. 2001;  122(1) 13-19
  • 3 Eljamel M S, Pidgeon C N. Localization of inactive cerebrospinal fistulas.  J Neurosurg. 1995;  83 795-798
  • 4 Sillers M J, Morgan C E, El Gammal T. Magnetic resonance cisternography and thin coronal computerized tomography in the evaluation of cerebrospinal fluid rhinorrhea.  Am J Rhinol. 1997;  11(5) 387-392
  • 5 Simmen D, Bischoff T, Schuknecht B. Experiences with assessment of frontobasal defects, a diagnostic concept.  Laryngorhinootologie. 1997;  76(10) 583-587
  • 6 Shetty P G, Shroff M M, Sahani D V, Kirtane M V. Evaluation of high-resolution CT and MR cisternography in the diagnosis of cerebrospinal fluid fistula.  Am J Neuroradiol. 1998;  19 633-639
  • 7 Lund V J, Savy L, Lloyd G, Howard D. Optimum imaging and diagnosis of cerebrospinal fluid rhinorrhea.  J Laryngol Otol. 2000;  114 988-992
  • 8 Colquhoun I R. CT cisternography in the investigation of cerebrospinal fluid rhinorrhea.  Clin Radiol. 1993;  47(6) 403-408
  • 9 Eljamel M S, Pidgeon C N, Toland J et al.. MRI cisternography, and the localization of CSF fistula.  Br J Neurosurg. 1994;  8(4) 433-437
  • 10 El Gammal T, Sobol W, Wadlington V R. Cerebrospinal fluid fistula: detection with MR cisternography.  Am J Neuroradiol. 1998;  19 627-631
  • 11 Murata Y, Yamada I, Suzuki S. MRI in spontaneous cerebrospinal fluid rhinorrhea.  Neuroradiology. 1995;  37(6) 453-455
  • 12 Ramsden J D, Corbridge R, Bates G. Bilateral cerebrospinal fluid rhinorrhea.  J Laryngol Otol. 2000;  114 137-138
  • 13 Levy L M, Gulya A J, Davis S W, LeBihan D, Rajan S S, Schellinger D. Flow-sensitive magnetic resonance imaging in the evaluation of cerebrospinal fluid leaks.  Am J Otol. 1995;  16(5) 591-596

Badr E MostafaM.D. 

48 Ibn El Nafees Street, Nasr City

11371 Cairo, Egypt

Email: bemostafa@balooshy.com

    >
    Skull Base 2004; 14(3): 162
    DOI: 10.1055/s-2004-832259
    Copyright © 2004 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA.

    Commentary

    Jacques J. Morcos1 ,
    • 1Department of Neurological Surgery, University of Miami, Miami, Florida
    Further Information

    Publication History

    Publication Date:
    24 August 2004 (online)

    Drs. Mostafa and Khafagi have reviewed their experience with the detection of cerebrospinal fluid (CSF) rhinorrhea and have suggested that fusing high-resolution coronal computed tomography (CT) images of the base of the skull with highly fat-suppressed T2-weighted magnetic resonance imaging (MRI) sequences might offer the best of both worlds, marrying high spatial resolution with the ability to visualize the continuity of CSF. Their success in 17 of 19 patients is impressive. One has to remember that the gold standard of CT Omnipaque studies is not particularly comfortable for patients, and the false-negative rate is appreciable. However, one must be cautious about performing CT and MRI in close temporal proximity. Furthermore, the angulation of the cuts must be similar to maximize accuracy of the fusion. I suspect, however, that in a larger series a certain degree of inaccuracy and misleading changes in the paranasal sinuses would still be encountered. In such cases, one could always refer to an intrathecal CT study.

    In summary, this article is a valuable addition to the literature. I intend to try this technique at my institution to see if we can replicate these encouraging results.

      >