Endoscopy 2017; 49(04): 327-333
DOI: 10.1055/s-0042-122779
Original article
© Georg Thieme Verlag KG Stuttgart · New York

Lumen-apposing covered self-expandable metal stents for short benign gastrointestinal strictures: a multicenter study

Dennis Yang
1   Division of Gastroenterology, University of Florida College of Medicine, Gainesville, Florida, United States
,
Jose M. Nieto
2   Borland-Groover Clinic, Jacksonville, Florida, United States
,
Ali Siddiqui
3   Jefferson University Hospitals, Division of Gastroenterology and Hepatology, Philadelphia, Pennsylvania, United States
,
Brian P. Riff
4   Division of Gastroenterology, Icahn School of Medicine at Mount Sinai, New York, New York, United States
,
Christopher J. DiMaio
4   Division of Gastroenterology, Icahn School of Medicine at Mount Sinai, New York, New York, United States
,
Satish Nagula
4   Division of Gastroenterology, Icahn School of Medicine at Mount Sinai, New York, New York, United States
,
Amr M. Ismail
5   Division of Gastroenterology and Hepatology, The Johns Hopkins Medical Institutions, Baltimore, Maryland, United States
,
Saowanee Ngamreungphong
5   Division of Gastroenterology and Hepatology, The Johns Hopkins Medical Institutions, Baltimore, Maryland, United States
,
Mouen A. Khashab
5   Division of Gastroenterology and Hepatology, The Johns Hopkins Medical Institutions, Baltimore, Maryland, United States
,
Mihir S. Wagh
6   Division of Gastroenterology, University of Colorado School of Medicine, Aurora, Colorado, United States
,
Demetrios Tzimas
7   Division of Gastroenterology and Hepatology, Stony Brook University School of Medicine, Stony Brook, New York, United States
,
Jonathan M. Buscaglia
7   Division of Gastroenterology and Hepatology, Stony Brook University School of Medicine, Stony Brook, New York, United States
,
Daniel S. Strand
8   Division of Gastroenterology and Hepatology, University of Virginia Health System, Charlottesville, Virginia, United States
,
Andrew Y. Wang
8   Division of Gastroenterology and Hepatology, University of Virginia Health System, Charlottesville, Virginia, United States
,
Shailendra S. Chauhan
9   CHS Digestive Health, Carolinas Medical Center, Charlotte, North Carolina, United States
,
Christopher E. Forsmark
1   Division of Gastroenterology, University of Florida College of Medicine, Gainesville, Florida, United States
,
Peter V. Draganov
1   Division of Gastroenterology, University of Florida College of Medicine, Gainesville, Florida, United States
› Author Affiliations
Further Information

Publication History

submitted 12 July 2016

accepted after revision 04 November 2016

Publication Date:
23 January 2017 (online)

Abstract

Background and study aim Use of the fully covered self-expandable metal stent (SEMS) for benign luminal gastrointestinal (GI) stricture (BLGS) has been limited by the migration rate. The role of the lumen-apposing metal stent (LAMS) for BLGS is not well defined. We assessed the safety, feasibility, and efficacy of LAMS for the treatment of BLGS.

Patients and methods This was an observational, open-label, retrospective, single-arm, multicenter consecutive case series of patients undergoing LAMS placement for BLGS. Technical success was defined as successful placement of the LAMS. Short- and long-term clinical success rates were defined as symptom improvement/resolution with indwelling stent and after stent removal, respectively. All adverse events and additional interventions were recorded.

Results A total of 30 patients (mean age 51.6 years; 63.3 % women) underwent LAMS placement for GI strictures (83.9 % anastomotic). Median stricture diameter and length were 4.5 mm (range 2 – 10 mm) and 8 mm (range 5 – 10 mm), respectively. Technical success was achieved in 29 patients (96.7 %), with an adverse event rate of 13.3 %. The stent migration rate was 8.0 % (2/25) on follow-up endoscopy. Short-term clinical success was achieved in 90.0 % (27/30) at a median of 60 days (interquartile range [IQR] 40 – 90 days). Most patients (19/23; 82.6 %) experienced sustained symptom improvement/resolution without the need for additional interventions at a median follow-up of 100 days (IQR 60 – 139 days) after LAMS removal.

Conclusion This multicenter study demonstrated that LAMS placement represents a safe, feasible, and effective therapeutic option for patients with BLGS and is associated with a low stent migration rate. Our initial findings suggest that future prospective comparative studies are needed on the use of LAMS, endoscopic dilation, and conventional SEMS. 

 
  • References

  • 1 Pereira-Lima JC, Ramires RP, Zamin Jr I. et al. Endoscopic dilation of benign esophageal strictures: report on 1043 procedures. Am J Gastroenterol 1999; 94: 1497-1501
  • 2 Siersema PD, de Wijkerslooth LR. Dilation of refractory benign esophageal strictures. Gastrointest Endosc 2009; 70: 1000-1012
  • 3 Tan BS, Kennedy C, Morgan R. et al. Using uncovered metallic endoprostheses to treat recurrent benign esophageal strictures. AJR Am J Roentgenol 1997; 169: 1281-1284
  • 4 Song HY, Park SI, Jung HY. et al. Benign and malignant esophageal strictures: treatment with a polyurethane-covered retrieval expandable metallic stent. Radiology 1997; 203: 747-752
  • 5 Fiorini A, Fleischer D, Valero J. et al. Self-expandable metal coil stents in the treatment of benign esophageal strictures refractory to conventional therapy: a case series. Gastrointest Endosc 2000; 52: 259-262
  • 6 Barthel JS, Kelley ST, Klapman JB. Management of persistent gastroesophageal anastomotic strictures with removable self-expandable polyester silicon-covered (Polyflex) stents: an alternative to serial dilation. Gastrointest Endosc 2008; 67: 546-552
  • 7 Siersema PD, Hirdes MM. What is the optimal duration of stent placement for refractory, benign esophageal strictures?. Nat Clin Pract Gastroenterol Hepatol 2009; 6: 146-147
  • 8 Sharma P, Kozarek R. ,Practice Parameters Committee of American College of Gastroenterology Role of esophageal stents in benign and malignant disease. Am J Gastroenterol 2009; 105: 258-273
  • 9 Gangloff A, Lecleire S, Di Fiore A. et al. Fully versus partially covered self-expandable metal stents in benign esophageal strictures. Dis Esophagus 2015; 28: 678-683
  • 10 Caruso A, Conigliaro R, Manta R. Fully covered self-expanding metal stents for refractory anastomotic colorectal strictures. Surg Endosc 2015; 29: 1175-1178
  • 11 Binmoeller KF, Shah J. A novel lumen-apposing stent for transluminal drainage of nonadherent extraintestinal fluid collections. Endoscopy 2011; 43: 337-342
  • 12 Itoi T, Reddy N, Yasuda I. New fully-covered self-expandable metal stent for endoscopic ultrasonography-guided intervention in infectious walled-off pancreatic necrosis (with video). J Hepatobiliary Pancreat Sci 2013; 20: 403-406
  • 13 Yang D, Draganov PV. EUS-guided transmural drainage of pancreatic fluid collections: keeping it close. Pancreat Disord Ther 2015; 1000e144
  • 14 Tyber A, Desai A, Zerbo S. et al. Endoscopic management of an anastomotic stricture using a lumen-apposing metal stent. Gastrointest Endosc 2016; 83: 464-465
  • 15 Uchima H, Abu-Suboh M, Mata A. et al. Lumen-apposing metal stent for the treatment of refactory gastrojejunal anastomotic stricture after laparoscopic gastric bypass. Gastrointest Endosc 2016; 83: 251
  • 16 Westerveld D, Yang D, Forsmark CE. et al. Endoscopic placement of a lumen-apposing metal stent for a persistent gastrojejunal anastomotic stricture after Roux-en-Y gastric bypass. J Gastro Hepato Dis 2016; 2: 107
  • 17 Majumder S, Buttar NS, Gostout C. et al. Lumen-apposing covered self-expanding metal stent for management of benign gastrointestinal strictures. Endosc Int Open 2016; 4: E96-E101
  • 18 Cotton PB, Eisen GM, Aabakken L. et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 2010; 71: 450-454
  • 19 Vazquez-Sequeiros E, Baron TH, Perez-Miranda M. et al. Evaluation of the short- and long-term effectiveness and safety of fully covered self-expandable metal stents for drainage of pancreatic fluid collections: results of a Spanish nationwide registry. Gastrointest Endosc 2016; 84: 450-457
  • 20 Walter D, Teoh AY, Perez-Miranda M. et al. EUS-guided gallbladder drainage with a lumen-apposing metal stent: a prospective long-term evaluation. Gut 2016; 65: 6-8
  • 21 Moon JH, Choi HJ, Kim DC. et al. A newly designed fully covered metal stent for lumen apposition in EUS-guided drainage and access: a feasibility study (with videos). Gastrointest Endosc 2014; 79: 990-995
  • 22 Repici A, Small AJ, Mendelson A. et al. Natural history and management of refractory benign esophageal strictures. Gastrointest Endosc 2016; 84: 222-228
  • 23 Cereatti F, Fiocca F, Dumont JL. et al. Fully covered self-expandable metal stent in the treatment of postsurgical colorectal diseases: outcome in 29 patients. Therap Adv Gastroenterol 2016; 9: 180-188
  • 24 Fuccio L, Hassan C, Frazzoni L. et al. Clinical outcomes following stent placement in refractory benign esophageal strictures: a systematic review and meta-analysis. Endoscopy 2016; 48: 141-148
  • 25 Freedman J, Jonas E, Näslund E. et al. Treatment of leaking gastrojejunostomy after gastric bypass surgery with special emphasis on stenting. Surg Obes Relat Dis 2013; 9: 554-558
  • 26 Hoeppner J, Kulemann B, Seifert G. et al. Covered self-expanding stent treatment for anastomotic leakage: outcomes in esophagogastric and esophagojejunal anastomoses. Surg Endosc 2014; 28: 1703-1711