Vet Comp Orthop Traumatol 2015; 28(05): 355-358
DOI: 10.3415/VCOT-15-01-0005
Brief Communication
Schattauer GmbH

Biomechanical properties of the atlantoaxial joint with naturally-occurring instability in a toy breed dog

A comparative descriptive cadaveric study
F. Forterre
1   Division of Small Animal Surgery, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland
,
C. Precht
2   Division of Radiology, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland
,
B. Riedinger
1   Division of Small Animal Surgery, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland
,
A. Bürki
3   MEM Research Center, Institute for Surgical Technology and Biomechanics, University of Bern, Bern, Switzerland
› Author Affiliations
Further Information

Publication History

Received:05 January 2015

Accepted:29 April 2015

Publication Date:
28 December 2017 (online)

Summary

The biomechanical properties of the atlanto-axial joint in a young Yorkshire Terrier dog with spontaneous atlantoaxial instability were compared to those of another young toy breed dog with a healthy atlantoaxial joint. The range-of-motion was increased in flexion and lateral bending in the unstable joint. In addition, lateral bending led to torsion and dorsal dislocation of the axis within the atlas. On gross examination, the dens ligaments were absent and a longitudinal tear of the tectorial membrane was observed. These findings suggest that both ventral and lateral flexion may lead to severe spinal cord compression, and that the tectorial membrane may play a protective role in some cases of atlantoaxial instability.

 
  • References

  • 1 Reber K, Bürki A, Vizcaino Reves N. et al. Biomechanical evaluation of the stabilizing function of the atlantoaxial ligaments under shear loading: a canine cadaveric study. Vet Surg 2013; 42: 918-923.
  • 2 Riedinger B, Forterre F, Bürki A. Biomechanical evaluation of the stabilizing function of three atlantoaxial implants under shear loading: A canine cadaveric study. Vet Surg 2014; 43: E195
  • 3 Gedet P, Thistlethwaite PA, Ferguson SJ. Minimizing errors during in vitro testing of multisegmental spine specimens: considerations for component selection and kinematic measurement. J Biomech 2007; 40: 1881-1885.
  • 4 Havig ME, Cornell KK, Hawthorne JC. et al. Evaluation of non-surgical treatment of atlantoaxial subluxation in dogs: 19 cases (1992-2001). J Am Vet Med Assoc 2005; 227: 257-262.
  • 5 Middleton G, Hillmann DJ, Trichel J. et al. Magnetic resonance imaging of the ligamentous structures of the occipitoatlantoaxial region in the dog. Vet Radiol Ultrasound 2012; 53: 545-551.