Rofo 2005; 177(10): 1366-1372
DOI: 10.1055/s-2005-858563
Kinderradiologie

© Georg Thieme Verlag KG Stuttgart · New York

Multi-Detektor-CT zur Diagnostik angeborener Gefäßanomalien und ihrer Begleitbefunde bei Neugeborenen und Kleinkindern

Multidetector CT of Congenital Vascular Anomalies and Associated Complications in Newborns and InfantsJ. G. Eichhorn1 , C. Fink2 , F. Long3 , R. Arnold1 , S. Ley2 , H. Ulmer1 , H.-U Kauczor2
  • 1Universitätskinderklinik, Pädiatrische Kardiologie, Heidelberg
  • 2Deutsches Krebsforschungszentrum, Radiologie, Heidelberg
  • 3Columbus Children's Hospital, Pediatric Radiology Columbus, Ohio, United States
Further Information

Publication History

eingereicht: 1.2.2005

angenommen: 13.4.2005

Publication Date:
16 September 2005 (online)

Zusammenfassung

Ziel: Evaluation der Multi-Detektor-CT (MDCT) zur Diagnostik angeborener Gefäßanomalien (VA) und ihrer Begleitbefunde bei Neugeborenen und Kleinkindern. Material und Methoden: 75 Patienten (Pat., mittleres Alter: 9 ± 6 Monate [œ bis 24 Mon.]) mit VA wurden mittels MDCT (4-, 8- und 16-Zeilen; Kollimination 0,5 - 1,25 mm; Scanzeit 7 - 30 s) unter kontrollierter Ventilation oder freier Atmung untersucht. Die Bildqualität wurde nach einem 5-Punkte-Score bewertet. Als Goldstandard diente die Kombination von Echokardiographie, Katheterangiographie (kKA), Bronchoskopie und intraoperativem Befund. Ergebnisse: Bei allen Pat. konnten die Morphologie und Topographie der VA klar beurteilt und die Diagnose mit hoher Sicherheit gestellt werden. Aufgrund der hohen Ortsauflösung konnten selbst Gefäße mit einem Durchmesser unter 1 mm identifiziert werden. Begleitbefunde wie eine Kompression des Tracheobronchialsystems konnten sicher beurteilt werden. Bei 31/75 Pat. war keine zusätzliche kKA zur Operationsplanung oder zum Ausschluss einer VA erforderlich. Bei weiteren 29 Pat. konnten die Durchleuchtungs- und Narkosezeit der interventionellen Therapie verkürzt werden. Schlussfolgerung: Die MDCT erlaubt eine nicht-invasive Diagnostik angeborener Gefäßanomalien und ihrer begleitenden Komplikationen des Tracheobronchialbaumes bei Neugeborenen und Kleinkindern. Aufgrund der hohen räumlichen Auflösung und der Möglichkeit der dreidimensionalen Nachverarbeitung erscheint die MDCT in der Diagnostik der Gefäßanomalien zumindest äquivalent zur invasiven Katheterangiographie.

Abstract

Purpose: To assess the value of multidetector CT (MDCT) for evaluation of vascular anomalies (VA) and associated complications in newborns and infants. Materials and Methods: Seventy-five children (mean age: 9 ± 6 months, range: 2 weeks to 24 months) with VA were examined using MDCT (4-, 8- or 16-row; collimation 0.5 - 1.25 mm; scan time 7 - 30 s), which was performed under controlled ventilation or free breathing. Image quality was rated using a 5-point scale. Image findings were correlated to echocardiography, conventional catheter angiography (CCA), bronchoscopy, and intraoperative findings. Results: High quality MDCT data were almost free of cardiac and respiratory motion. In all cases, VA morphology and topography in relation to adjacent structures, e. g. tracheal and esophageal compression caused by an aortic ring, could be assessed exactly and allowed the final diagnosis. Even aberrant vessels, such as aorto-pulmonary collaterals (MAPCA) with a diameter of less than 1 mm, could be identified and excellently visualized. Eighty percent (60/75) of all patients had benefited from the MDCT: in 31 patients CCA was neither necessary to perform surgical planning nor to exclude a VA; in an additional 29 patients radiation doses and sedation time due to interventional procedures could be reduced markedly. Conclusions: MDCT can now be regarded as the modality of choice as a minimally invasive, robust, and accurate technique for the diagnosis of complex VA, their potentially life-threatening complications and preoperative planning even in newborns and infants. Its accuracy for detecting VA appears equivalent to CCA while it is more accurate in delineating potential life-threatening complications.

Literatur

  • 1 Long F R, Castile R G, Brody A S. et al . Lungs in infants and young children: improved thin-section CT with a noninvasive controlled-ventilation technique - initial experience.  Radiology. 1999;  212 588-593
  • 2 Haramati L B, Glickstein J S, Issenberg H J. et al . MR imaging and CT of vascular anomalies and connections in patients with congenital heart disease: significance in surgical planning.  Radiographics. 2002;  22 337-347
  • 3 Siegel M J. Multiplanar and three-dimensional multi-detector row CT of thoracic vessels and airways in the pediatric population.  Radiology. 2003;  229 641-650
  • 4 Boxt L M. Magnetic resonance and computed tomographic evaluation of congenital heart disease.  J Magn Reson Imaging. 2004;  19 827-847
  • 5 Eichhorn J, Fink C, Delorme S. et al . Rings, slings and other vascular abnormalities - Ultrafast computed tomography and magnetic resonance angiography in pediatric cardiology.  Z Kardiol. 2004;  93 201-208
  • 6 Lenfant C. Report of the Task Force on Research in Pediatric Cardiovascular Disease.  Circulation. 2002;  106 1037-1042
  • 7 Sechtem U. Task Force Report The clinical role of the magnetic resonance on cardiovascular disease. Task Force of the Eurepean Society of Cardiology, in collaboration with the Association of Eurepean Paediatric Cardiologists.  European Heart Journal. 1998;  19 19-39
  • 8 Sebening C, Jakob H, Tochtermann U. et al . Vascular tracheo-bronchial compression syndromes - Experience in surgical treatment and literature review.  Thorac Cardiov Surg. 2000;  48 164-174
  • 9 Eichhorn J, Schoenberg S, Ulmer H E. Cardiac-gated multislice computerised tomographic angiography in the preoperative evaluation of an infant with tetralogy of Fallot and pulmonary atresia.  Cardiol Young. 2003;  13 466-468
  • 10 Long F R, Castile R G. Technique and clinical applications of full-inflation and end-exhalation controlled-ventilation chest CT in infants and young children.  Pediatr Radiol. 2001;  31 413-422
  • 11 Goo H W, Park I S, Ko J K. et al . CT of congenital heart disease: normal anatomy and typical pathologic conditions.  RadioGraphics. 2003;  23 147-165
  • 12 Schultz F W, Geleijns J, Spoelstra F M. et al . Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterization.  Br J Radiol. 2003;  76 638-647
  • 13 Fink C, Eichhorn J, Kiessling F. et al . Zeitlich aufgelöste multiphasische 3D MR Angiographie zur Diagnostik des Lungengefäßsystems bei Kindern.  Fortschr Röntgenstr. 2003;  175 929-935
  • 14 Greil G F, Geva T, Maier S E. et al . Gadolinium-enhanced 3-dimensional MR angiography of pulmonary and systemic venous anomalies.  J Am Coll Cardiol. 2002;  39 335-341
  • 15 Yucel E K, Anderson C M, Edelman R R. Magnetic resonance angiography - Update on applications for extracranial arteries.  Circulation. 1999;  100 2284-2301

Dr. Joachim G. Eichhorn

Universitätskinderklinik, Pädiatrische Kardiologie

Im Neuenheimer Feld 153

69120 Heidelberg

Phone: ++ 49/62 21/56 23 48

Fax: ++ 49/62 21/56 57 90

Email: eichhorn.12@osu.edu