Endoscopy 2004; 36(4): 344-347
DOI: 10.1055/s-2004-814305
Case Report
© Georg Thieme Verlag Stuttgart · New York

A Case of Inflammatory Fibroid Polyp Causing Small-Bowel Intussusception in which Retrograde Double-Balloon Enteroscopy was Useful for the Preoperative Diagnosis

T.  Miyata1 , H.  Yamamoto1 , H.  Kita1 , T.  Yano1 , K.  Sunada1 , Y.  Sekine1 , M.  Iwamoto1 , A.  Kuno1 , N.  Onishi1 , K.  Ido1 , M.  Nokubi2 , A.  Tanaka2 , K.  Sugano1
  • 1Department of Internal Medicine, Division of Gastroenterology, Jichi Medical School, Mianamikawachi, Tochigi, Japan
  • 2Department of Pathology, Jichi Medical School, Mianamikawachi, Tochigi, Japan
Further Information

Publication History

Submitted 27 June 2003

Accepted after revision 5 August 2003

Publication Date:
01 April 2004 (online)

We showed a newly developed method, retrograde double-balloon enteroscopy, to be useful for preoperative diagnosis in a case of inflammatory fibroid polyp accompanied by small-bowel intussusception. A 64-year-old woman was admitted to our hospital with small-bowel intussusception. Results of radiographic and ultrasonographic examination were suggestive of a small-bowel mass. Retrograde double-balloon enteroscopy was performed in an attempt to make a preoperative diagnosis. Endoscopic observation, in combination with histological findings derived from endoscopic biopsy, was suggestive of an inflammatory fibroid polyp. The patient then underwent laparotomy with minimal incision, which revealed a polypoid mass leading to a jejunojejunal intussusception, without bowel necrosis, and a partial small-bowel resection was performed. The pathological diagnosis was an inflammatory fibroid polyp.

References

  • 1 Appleyard M, Glukhovsky A, Swain P. Wireless-capsule diagnostic endoscopy for recurrent small-bowel bleeding.  N Engl J Med. 2001;  344 232-233
  • 2 Iddan G, Meron G, Glukhovsky A. et al . Wireless capsule endoscopy.  Nature. 2000;  405 417
  • 3 Costamagna G, Shah S K, Riccioni M E. et al . A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease.  Gastroenterology. 2002;  123 999-1005
  • 4 Ell C, Remke S, May A. et al . The first prospective controlled trial comparing wireless capsule endoscopy with push enteroscopy in chronic gastrointestinal bleeding.  Endoscopy. 2002;  34 685-689
  • 5 Appleyard M, Fireman Z, Glukhovsky A. et al . A randomized trial comparing wireless capsule endoscopy with push enteroscopy for the detection of small-bowel lesions.  Gastroenterology. 2000;  119 1431-1438
  • 6 Faigel D O, Fennerty M B. ”Cutting the cord” for capsule endoscopy.  Gastroenterology. 2002;  123 1385-1388
  • 7 Yamamoto H, Sekine Y, Sato Y. et al . Total enteroscopy with a nonsurgical steerable double-balloon method.  Gastrointest Endosc. 2001;  53 216-220
  • 8 Yamamoto H, Yano T, Kita H. et al . New system of double-balloon enteroscopy for diagnosis and treatment of small intestinal disorders.  Gastroenterology. 2003;  125 1556-1557
  • 9 Riddell R H, Petras R P, Williams G T. et al .Tumors of the intestine. Atlas of tumor pathology. Washington, DC: Armed Forces Institute of Pathology; 2003 3rd Series; fascicle 32: 62-66
  • 10 Waye J D. Enteroscopy.  Gastrointest Endosc. 1997;  46 247-256
  • 11 Rossini F P, Pennazio M. Small-bowel endoscopy.  Endoscopy. 2002;  34 13-20
  • 12 Bar-Meir S, Bardan E. Wireless capsule endoscopy - pros and cons.  Isr Med Assoc J. 2002;  4 726

H. Yamamoto, M. D.

Department of Internal Medicine, Division of Gastroenterology ·

Jichi Medical School · 3311-1 Yakushiji · Minamikawachi · Tochigi, 329-0498 · Japan

Fax: +81-285-44-8297

Email: yamamoto@jichi.ac.jp