Anästhesiol Intensivmed Notfallmed Schmerzther 2001; 36(Suppl 1): 45-50
DOI: 10.1055/s-2001-11838
QUALITÄTSKONTROLLE UND DIAGNOSTIK
ORIGINALARBEIT
© Georg Thieme Verlag Stuttgart · New York

Qualitätskontrolle der Hämolyserate von Erythrozytenkonzentraten: Ringversuch zur Bestimmung von freiem Hämoglobin

K. Tapernon1 , R. Zander2 , D. Niehoff1 , W. Sibrowski1
  • 1Institut für Transfusionsmedizin und Transplantationsimmunologie, Universität Münster
  • 2Institut für Physiologie und Pathophysiologie, Universität Mainz
Further Information

Publication History

Publication Date:
31 December 2001 (online)

Literatur

  • 1 Bauer K. Determination of free haemoglobin in serum by automated assay, using 4-Aminophenazon and the cobas bio system.  J Clin Chem Clin Biochem . 1981;  19 971-976
  • 2 Bednar R, Bayer P M. Freies Hämoglobin im Plasma - Vergleich zweier spektalphotometischer Methoden.  Lab Med. 1994;  18 196-199
  • 3 Bundschuh G, Schneeweiss B, Bräuner H. Biotest Lexikon der Immunologie (2. Aufl.).  Akademie, Berlin. 1992;  343
  • 4 Council of Europe Publishing .Guide to the preparation, use and quality assurance of blood components. 5th edition 1999: 84
  • 5 Crosby W H, Furth F W. A modification of the benzidine method for measurment of hemoglobin in plasma and urine.  Blood. 1956;  11 380-383
  • 6 Engelhardt A. Klinische Chemie und Laboratoriumsdiagnostik (2. Aufl.).  Schattauer, Stuttgart. 1974;  128
  • 7 Engler R, Pointis J, Rondeau Y, Judon C, Waks M. Determination immunochimique de l'hemoglobine humaine dans les liquides biologiques.  Clin Chim Acta. 1979;  77 159-165
  • 8 Fairbanks V F, Ziesmer S C, O'Brien P C. Methods for measuring plasma hemoglobin in micromolar concentration compared.  Clin Chem. 1992;  38 132-140
  • 9 Golf S W, Schneider S, Friemann E, Temme H, Roka L. Correction of catalytic activities of aspartate aminotransferase, lactat dehydrogenase, acid phosphatase and potassium concentration in haemolytic plasma by determination of haemoglobin concentration with direct spectrophotometry.  J Clin Chem Clin Biochem. 1985;  23 585
  • 10 Harboe M. A method for determination of hemoglobin in plasma by near ultraviolet spectrophotometry.  Scand Clin Lab Invest. 1959;  11 60-70
  • 11 Henry R J, Cannon D C, Winkelman J W. Clinical chemistry, principles and technics (2nd ed.).  Harper and Row, New York. 1974;  1139-1140
  • 12 Lammers M, Gressner A M. Immunnephelometric quantifikation of free haemoglobin.  J Clin Chem Clin Biochem. 1987;  25 363-367
  • 13 Noe D A, Weedn V, Bell W R. Direct spectrometry of serum hemoglobin: An Allen correction compared with three-wavelength polychromatic analysis.  Clin Chem. 1985;  30 627-630
  • 14 Rick W. Klinische Chemie und Mikroskopie (6. Aufl.).  Springer, Berlin. 1990;  67-68
  • 15 Standefer J C, Vanderjagt D. Use of tetramethylbenzidine in plasma hemoglobin assay.  Clin Chem. 1977;  23 749-751
  • 16 Tietz N W. Fundamentals of clinical chemistry (3rd. ed.).  WB Saunders, Philadelphia. 1987;  804-805
  • 17 Van Kampen E J, Zijlstra W G. Standardization of hemoglobinometry, the hemiglobincyanid method.  Clin Chim Acta. 1961;  6 538-544
  • 18 Virella G, Munoz J. Rapid immunochemical determination of free hemoglobin in plasma and urine with a laser nephelometer.  Clin Chem. 1979;  25 497-498

Dr. med. Karin Tapernon

Institut für Transfusionsmedizin
und Transplantationsimmunologie
Westfälische Wilhelms-Universität Münster

Domagkstraße 11

48149 Münster

Email: tapernon@uni-muenster.de

    >