J Wrist Surg 2014; 03(01): 042-045
DOI: 10.1055/s-0033-1364096
Case Report
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

One Size Does Not Fit All: Distal Radioulnar Joint Dysfunction after Volar Locking Plate Fixation

Christopher W. Jones
1   Orthopaedic Registrar, NSW Northside Training Program, Royal Australian College of Surgeons, Victoria, Australia
,
Richard D. Lawson
2   Hand Surgeon, Royal North Shore Hospital, Sydney, NSW, Australia
› Author Affiliations
Further Information

Publication History

Publication Date:
12 February 2014 (online)

Abstract

Background Fractures of the distal radius are among the most common injuries treated by orthopedic surgeons worldwide. Failure to restore distal radius alignment can lead to fracture malunion and poor clinical outcomes, including distal radioulnar joint (DRUJ) instability and limitation of motion.

Case Description We present a unique case of DRUJ dysfunction following volar plate fixation of bilateral distal radius fractures and analyze the biomechanical causes of this complication. As a result of a relatively excessive tilt of the precontoured locking plate (in comparison to the patient's particular anatomy), the fracture on one side was “over-reduced,” disrupting the biomechanics of the DRUJ, causing a supination block.

Clinical Relevance Volar locking plates are not a panacea to all distal radius fractures. Plate selection and fixation technique must include consideration of patient anatomy. Robust plates offer the advantage of providing rigid fixation but can be difficult to contour when reconstructing normal anatomy. Restoration of patient-specific anatomy is crucial to the management of distal radius fractures.

 
  • References

  • 1 Catalano III LW, Cole RJ, Gelberman RH, Evanoff BA, Gilula LA, Borrelli Jr J. Displaced intra-articular fractures of the distal aspect of the radius. Long-term results in young adults after open reduction and internal fixation. J Bone Joint Surg Am 1997; 79 (9) 1290-1302
  • 2 Crisco JJ, Moore DC, Marai GE , et al. Effects of distal radius malunion on distal radioulnar joint mechanics—an in vivo study. J Orthop Res 2007; 25 (4) 547-555
  • 3 Pogue DJ, Viegas SF, Patterson RM , et al. Effects of distal radius fracture malunion on wrist joint mechanics. J Hand Surg Am 1990; 15 (5) 721-727
  • 4 Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007; 21 (5) 316-322
  • 5 Hollevoet N, Van Maele G, Van Seymortier P, Verdonk R. Comparison of palmar tilt, radial inclination and ulnar variance in left and right wrists. J Hand Surg [Br] 2000; 25 (5) 431-433
  • 6 Hagert E, Hagert CG. Understanding stability of the distal radioulnar joint through an understanding of its anatomy. Hand Clin 2010; 26 (4) 459-466
  • 7 Linscheid RL. Biomechanics of the distal radioulnar joint. Clin Orthop Relat Res 1992; 275 (275) 46-55
  • 8 Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 2006; 31 (3) 359-365
  • 9 Bronstein AJ, Trumble TE, Tencer AF. The effects of distal radius fracture malalignment on forearm rotation: a cadaveric study. J Hand Surg Am 1997; 22 (2) 258-262
  • 10 Adams BD. Effects of radial deformity on distal radioulnar joint mechanics. J Hand Surg Am 1993; 18 (3) 492-498