J Knee Surg 2013; 26(01): 015-018
DOI: 10.1055/s-0033-1333899
Special Focus Section
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Far Cortical Locking Technology for Fixation of Periprosthetic Distal Femur Fractures: A Surgical Technique

Zachary G. Ries
1   Department of Orthopaedic Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
,
J. L. Marsh
1   Department of Orthopaedic Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
› Author Affiliations
Further Information

Publication History

04 December 2012

13 December 2012

Publication Date:
13 February 2013 (online)

Abstract

Far cortical locking screws have been shown to form greater amounts of callus in ovine studies when compared to traditional locking plates. These screws have recently become available for clinical use. This article describes the indications and surgical technique for far cortical locking screws, with a focus on distal femur periprosthetic fractures.

 
  • References

  • 1 Vallier HA, Immler W. Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures. J Orthop Trauma 2012; 26 (6) 327-332
  • 2 Henderson CE, Lujan TJ, Kuhl LL, Bottlang M, Fitzpatrick DC, Marsh JL. 2010 mid-America Orthopaedic Association Physician in Training Award: healing complications are common after locked plating for distal femur fractures. Clin Orthop Relat Res 2011; 469 (6) 1757-1765
  • 3 Bottlang M, Doornink J, Lujan TJ , et al. Effects of construct stiffness on healing of fractures stabilized with locking plates. J Bone Joint Surg Am 2010; 92 (Suppl. 02) 12-22
  • 4 Lujan TJ, Henderson CE, Madey SM, Fitzpatrick DC, Marsh JL, Bottlang M. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma 2010; 24 (3) 156-162
  • 5 Bottlang M, Feist F. Biomechanics of far cortical locking. J Orthop Trauma 2011; 25 (Suppl. 01) S21-S28
  • 6 Doornink J, Fitzpatrick DC, Madey SM, Bottlang M. Far cortical locking enables flexible fixation with periarticular locking plates. J Orthop Trauma 2011; 25 (Suppl. 01) S29-S34
  • 7 Bottlang M, Lesser M, Koerber J , et al. Far cortical locking can improve healing of fractures stabilized with locking plates. J Bone Joint Surg Am 2010; 92 (7) 1652-1660
  • 8 Gardner MJ, Nork SE, Huber P, Krieg JC. Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots. Injury 2010; 41 (6) 652-656
  • 9 Gardner MJ, Nork SE, Huber P, Krieg JC. Stiffness modulation of locking plate constructs using near cortical slotted holes: a preliminary study. J Orthop Trauma 2009; 23 (4) 281-287
  • 10 Sellei RM, Garrison RL, Kobbe P, Lichte P, Knobe M, Pape HC. Effects of near cortical slotted holes in locking plate constructs. J Orthop Trauma 2011; 25 (Suppl. 01) S35-S40