Subscribe to RSS
DOI: 10.1055/s-0031-1296030
Near Infrared Spectroscopy for Monitoring Flap Viability Following Breast Reconstruction
Publication History
22 March 2011
12 September 2011
Publication Date:
30 November 2011 (online)
Abstract
Free flap monitoring is essential to the early detection of compromise thereby increasing the chance of successful salvage surgery. Many alternatives to classical clinical monitoring have been proposed. This study seeks to investigate a relatively new monitoring technology: near infrared spectroscopy (NIRS). Patients were recruited prospectively to the study from a single center. During the research period, 10 patients underwent reconstruction with a free deep inferior epigastric perforator flap (DIEP). Measurements of flap perfusion were taken using NIRS in the preoperative and intraoperative phases and postoperatively for 72 hours. NIRS showed characteristic changes in all cases which returned to theater for pedicle compromise. In these cases, NIRS identified pedicle compromise prior to clinical identification. There were no false-positives. NIRS accurately identified all compromised flaps in our study. In most cases, there was an evidence of changes in oxygen saturation on NIRS prior to clinical observation. Further research, ideally double blind randomized control trials with large sample groups would be required to definitively establish NIRS as an ideal flap monitoring modality.
-
References
- 1 Ahn CY, Shaw WW, Berns S, Markowitz BL. Clinical experience with the 3M microvascular coupling anastomotic device in 100 free-tissue transfers. Plast Reconstr Surg 1994; 93 (7) 1481-1484
- 2 Spector JA, Draper LB, Levine JP, Ahn CY. Routine use of microvascular coupling device for arterial anastomosis in breast reconstruction. Ann Plast Surg 2006; 56 (4) 365-368
- 3 Jandali S, Wu LC, Vega SJ, Kovach SJ, Serletti JM. 1000 consecutive venous anastomoses using the microvascular anastomotic coupler in breast reconstruction. Plast Reconstr Surg 2010; 125 (3) 792-798
- 4 Bui DT, Cordeiro PG, Hu QY, Disa JJ, Pusic A, Mehrara BJ. Free flap reexploration: indications, treatment, and outcomes in 1193 free flaps. Plast Reconstr Surg 2007; 119 (7) 2092-2100
- 5 Disa JJ, Cordeiro PG, Hidalgo DA. Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases. Plast Reconstr Surg 1999; 104 (1) 97-101
- 6 Pratt GF, Rozen WM, Chubb D , et al. Modern adjuncts and technologies in microsurgery: an historical and evidence-based review. Microsurgery 2010; 30 (8) 657-666
- 7 Repez A, Oroszy D, Arnez ZM. Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy. J Plast Reconstr Aesthet Surg 2008; 61 (1) 71-77
- 8 Stranc MF, Sowa MG, Abdulrauf B, Mantsch HH. Assessment of tissue viability using near-infrared spectroscopy. Br J Plast Surg 1998; 51 (3) 210-217
- 9 Thorniley MS, Sinclair JS, Barnett NJ, Shurey CB, Green CJ. The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery. Br J Plast Surg 1998; 51 (3) 218-226
- 10 Hayden RE, Tavill MA, Nioka S, Kitai T, Chance B. Oxygenation and blood volume changes in flaps according to near-infrared spectrophotometry. Arch Otolaryngol Head Neck Surg 1996; 122 (12) 1347-1351
- 11 Irwin MS, Thorniley MS, Doré CJ, Green CJ. Near infra-red spectroscopy: a non-invasive monitor of perfusion and oxygenation within the microcirculation of limbs and flaps. Br J Plast Surg 1995; 48 (1) 14-22
- 12 Cai ZG, Zhang J, Zhang JG , et al. Evaluation of near infrared spectroscopy in monitoring postoperative regional tissue oxygen saturation for fibular flaps. J Plast Reconstr Aesthet Surg 2008; 61 (3) 289-296
- 13 Colwell AS, Wright L, Karanas Y. Near-infrared spectroscopy measures tissue oxygenation in free flaps for breast reconstruction. Plast Reconstr Surg 2008; 121 (5) 344e-345e
- 14 Keller A. Noninvasive tissue oximetry for flap monitoring: an initial study. J Reconstr Microsurg 2007; 23 (4) 189-197
- 15 Keller A. A new diagnostic algorithm for early prediction of vascular compromise in 208 microsurgical flaps using tissue oxygen saturation measurements. Ann Plast Surg 2009; 62 (5) 538-543
- 16 Shan XF, Cai ZG, Yu GY, Li Y, Ding HS. [Application of near infrared spectroscopy in monitoring blood oxygen saturation of fibula flaps]. Zhonghua Kou Qiang Yi Xue Za Zhi 2008; 43 (7) 398-401
- 17 Scheufler O, Andresen R. Tissue oxygenation and perfusion in inferior pedicle reduction mammaplasty by near-infrared reflection spectroscopy and color-coded duplex sonography. Plast Reconstr Surg 2003; 111 (3) 1131-1146
- 18 Scheufler O, Exner K, Andresen R. Investigation of TRAM flap oxygenation and perfusion by near-infrared reflection spectroscopy and color-coded duplex sonography. Plast Reconstr Surg 2004; 113 (1) 141-152, discussion 153–155
- 19 Creech B, Miller S. Evaluation of circulation in skin flaps. In: Grabb WC, Myers MB, eds. Skin Flaps. 1975: 21-38
- 20 Lindsey LA, Watson JD, Quaba AA. Pulse oximetry in postoperative monitoring of free muscle flaps. Br J Plast Surg 1991; 44 (1) 27-29
- 21 Achauer BM, Black KS, Beran AV, Huxtable RF. Transcutaneous PO2 monitoring of flap circulation following surgery. Birth Defects Orig Artic Ser 1979; 15 (4) 517-522
- 22 Stack Jr BC, Futran ND, Shohet MJ, Scharf JE. Spectral analysis of photoplethysmograms from radial forearm free flaps. Laryngoscope 1998; 108 (9) 1329-1333
- 23 Stack Jr BC, Futran ND, Zang B, Scharf JE. Initial experience with personal digital assistant-based reflectance photoplethysmograph for free tissue transfer monitoring. Ann Plast Surg 2003; 51 (2) 136-140
- 24 Chiu ES, Altman A, Allen Jr RJ, Allen Sr RJ. Free flap monitoring using skin temperature strip indicators: adjunct to clinical examination. Plast Reconstr Surg 2008; 122 (5) 144e-145e
- 25 Issing WJ, Naumann C. Evaluation of pedicled skin flap viability by pH, temperature and fluorescein: an experimental study. J Craniomaxillofac Surg 1996; 24 (5) 305-309
- 26 Denneny III JC, Weisman RA, Silverman DG. Monitoring free flap perfusion by serial fluorometry. Otolaryngol Head Neck Surg 1983; 91 (4) 372-376
- 27 Udesen A, Løntoft E, Kristensen SR. Monitoring of free TRAM flaps with microdialysis. J Reconstr Microsurg 2000; 16 (2) 101-106
- 28 Mourouzis C, Anand R, Bowden JR, Brennan PA. Microdialysis: use in the assessment of a buried bone-only fibular free flap. Plast Reconstr Surg 2007; 120 (5) 1363-1366
- 29 Rosenberg JJ, Fornage BD, Chevray PM. Monitoring buried free flaps: limitations of the implantable Doppler and use of color duplex sonography as a confirmatory test. Plast Reconstr Surg 2006; 118 (1) 109-113, discussion 114–115
- 30 Prantl L, Pfister K, Kubale R , et al. Value of high resolution ultrasound and contrast enhanced US pulse inversion imaging for the evaluation of the vascular integrity of free-flap grafts. Clin Hemorheol Microcirc 2007; 36 (3) 203-216
- 31 Whitaker IS, Smit JM, Acosta R. A simple method of implantable Doppler cuff attachment: experience in 150 DIEP breast reconstructions. J Plast Reconstr Aesthet Surg 2008; 61 (10) 1251-1252
- 32 Swartz WM, Izquierdo R, Miller MJ. Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results. Plast Reconstr Surg 1994; 93 (1) 152-163
- 33 Yuen JC, Feng Z. Monitoring free flaps using the laser Doppler flowmeter: five-year experience. Plast Reconstr Surg 2000; 105 (1) 55-61
- 34 Svensson H, Pettersson H, Svedman P. Laser Doppler flowmetry and laser photometry for monitoring free flaps. Scand J Plast Reconstr Surg 1985; 19 (3) 245-249
- 35 Concannon MJ, Stewart DH, Welsh CF, Puckett CL. Impedance plethysmography: a new method for continuous muscle perfusion monitoring. Plast Reconstr Surg 1991; 88 (2) 292-298
- 36 Harrison DH, Mott G. Impedance monitoring for subcutaneous free flap transfers. Br J Plast Surg 1989; 42 (3) 318-323
- 37 Altintas MA, Altintas AA, Guggenheim M, Knobloch K, Niederbichler AD, Vogt PM. Monitoring of microcirculation in free transferred musculocutaneous latissimus dorsi flaps by confocal laser scanning microscopy—a promising non-invasive methodical approach. J Plast Reconstr Aesthet Surg 2010; 63 (1) 111-117
- 38 Top H, Sarikaya A, Aygit AC, Benlier E, Kiyak M. Review of monitoring free muscle flap transfers in reconstructive surgery: role of 99mTc sestamibi scintigraphy. Nucl Med Commun 2006; 27 (1) 91-98
- 39 Aygit AC, Sarikaya A. Technetium 99m sestamibi scintigraphy for noninvasive assessment of muscle flap viability. Ann Plast Surg 1999; 43 (3) 338-340
- 40 Raskin DJ, Erk Y, Spira M, Melissinos EG. Tissue pH monitoring in microsurgery: a preliminary evaluation of continuous tissue pH monitoring as an indicator of perfusion disturbances in microvascular free flaps. Ann Plast Surg 1983; 11 (4) 331-339
- 41 Dickson MG, Sharpe DT. Continuous subcutaneous tissue pH measurement as a monitor of blood flow in skin flaps: an experimental study. Br J Plast Surg 1985; 38 (1) 39-42
- 42 Machens HG, Mailaender P, Reimer R, Pallua N, Lei Y, Berger A. Postoperative blood flow monitoring after free-tissue transfer by means of the hydrogen clearance technique. Plast Reconstr Surg 1997; 99 (2) 493-505
- 43 Thomson JG, Kerrigan CL. Hydrogen clearance: assessment of technique for measurement of skin-flap blood flow in pigs. Plast Reconstr Surg 1991; 88 (4) 657-663
- 44 Hallock GG, Koch TJ. External monitoring of vascularized jejunum transfers using laser Doppler flowmetry. Ann Plast Surg 1990; 24 (3) 213-215
- 45 Hölzle F, Loeffelbein DJ, Nolte D, Wolff K-D. Free flap monitoring using simultaneous non-invasive laser Doppler flowmetry and tissue spectrophotometry. J Craniomaxillofac Surg 2006; 34 (1) 25-33
- 46 Whitaker IS, Oliver DW, Ganchi PA. Postoperative monitoring of microvascular tissue transfers: current practice in the United kingdom and Ireland. Plast Reconstr Surg 2003; 111 (6) 2118-2119
- 47 Whitaker IS, Gulati V, Ross GL, Menon A, Ong TK. Variations in the postoperative management of free tissue transfers to the head and neck in the United Kingdom. Br J Oral Maxillofac Surg 2007; 45 (1) 16-18
- 48 Smit JM, Acosta R, Zeebregts CJ, Liss AG, Anniko M, Hartman EHM. Early reintervention of compromised free flaps improves success rate. Microsurgery 2007; 27 (7) 612-616
- 49 Smit JM, Zeebregts CJ, Acosta R. Timing of presentation of the first signs of vascular compromise dictates the salvage outcome of free flap transfers. Plast Reconstr Surg 2008; 122 (3) 991-992
- 50 Hofer SO, Damen TH, Mureau MA, Rakhorst HA, Roche NA. A critical review of perioperative complications in 175 free deep inferior epigastric perforator flap breast reconstructions. Ann Plast Surg 2007; 59 (2) 137-142