Abstract
Objective Our study identified risk factors for the development of clinically identifiable catheter-associated thrombosis (CT).
Study Design We performed a retrospective cohort study of neonates in whom a central catheter was present. A total of 1,475 catheters were identified in 766 patients during a 36-month study period. The odds ratio (OR) of thrombi formation in catheterized neonates was modeled using simple (single predictor) and multiple (multiple predictors) logistic regressions as well as simple and multiple Cox's proportional hazard models.
Result The incidence of CT was 1.17 per 100 neonates. Unadjusted factors including age at insertion, history of surgery before or during line placement, cholestasis, femoral location, and line size significantly increased the OR or hazards ratio (HR) of developing thrombi formation. In multiple logistic and Cox's regression analyses, three factors continued to be significantly associated with OR or HR of thrombi formation: line size, femoral location, and cholestasis.
Conclusion We conclude that clinically identifiable CT is rare in the neonatal population. Furthermore, catheter-specific characteristics are predictive for CT and require further investigation.
-
References
- 1 Camara D. Minimizing risks associated with peripherally inserted central catheters in the NICU. MCN Am J Matern Child Nurs 2001; 26 (01) 17-21
- 2 Revel-Vilk S, Ergaz Z. Diagnosis and management of central-line-associated thrombosis in newborns and infants. Semin Fetal Neonatal Med 2011; 16 (06) 340-344
- 3 Saxonhouse MA. Thrombosis in the neonatal intensive care unit. Clin Perinatol 2015; 42 (03) 651-673
- 4 Bhat R, Monagle P. The preterm infant with thrombosis. Arch Dis Child Fetal Neonatal Ed 2012; 97 (06) F423-F428
- 5 Amankwah EK, Atchison CM, Arlikar S. , et al. Risk factors for hospital-sssociated venous thromboembolism in the neonatal intensive care unit. Thromb Res 2014; 134 (02) 305-309
- 6 Park CK, Paes BA, Nagel K, Chan AK, Murthy P. ; Thrombosis and Hemostasis in Newborns (THiN) Group. Neonatal central venous catheter thrombosis: diagnosis, management and outcome. Blood Coagul Fibrinolysis 2014; 25 (02) 97-106
- 7 Raffini L, Huang YS, Witmer C, Feudtner C. Dramatic increase in venous thromboembolism in children's hospitals in the United States from 2001 to 2007. Pediatrics 2009; 124 (04) 1001-1008
- 8 Schmidt B, Andrew M. Neonatal thrombosis: report of a prospective Canadian and international registry. Pediatrics 1995; 96 (5 Pt 1): 939-943
- 9 Tanke RB, van Megen R, Daniëls O. Thrombus detection on central venous catheters in the neonatal intensive care unit. Angiology 1994; 45 (06) 477-480
- 10 Turebylu R, Salis R, Erbe R, Martin D, Lakshminrusimha S, Ryan RM. Genetic prothrombotic mutations are common in neonates but are not associated with umbilical catheter-associated thrombosis. J Perinatol 2007; 27 (08) 490-495
- 11 Haley KM. Neonatal venous thromboembolism. Front Pediatr 2017; 5: 136
- 12 Wever ML, Liem KD, Geven WB, Tanke RB. Urokinase therapy in neonates with catheter related central venous thrombosis. Thromb Haemost 1995; 73 (02) 180-185
- 13 Kenet G, Limperger V, Shneyder M, Nowak-Göttl U. Risk factors for symptomatic venous and arterial thromboembolism in newborns, children and adolescents - what did we learn within the last 20years?. Blood Cells Mol Dis 2017; 67: 18-22
- 14 van Ommen CH, Sol JJ. Developmental hemostasis and management of central venous catheter thrombosis in neonates. Semin Thromb Hemost 2016; 42 (07) 752-759
- 15 Kim JH, Lee YS, Kim SH, Lee SK, Lim MK, Kim HS. Does umbilical vein catheterization lead to portal venous thrombosis? Prospective US evaluation in 100 neonates. Radiology 2001; 219 (03) 645-650
- 16 Chopra V, Anand S, Hickner A. , et al. Risk of venous thromboembolism associated with peripherally inserted central catheters: a systematic review and meta-analysis. Lancet 2013; 382 (9889): 311-325
- 17 Jaffer IH, Fredenburgh JC, Hirsh J, Weitz JI. Medical device-induced thrombosis: what causes it and how can we prevent it?. J Thromb Haemost 2015; 13 (Suppl. 01) S72-S81
- 18 Sharp R, Cummings M, Fielder A, Mikocka-Walus A, Grech C, Esterman A. The catheter to vein ratio and rates of symptomatic venous thromboembolism in patients with a peripherally inserted central catheter (PICC): a prospective cohort study. Int J Nurs Stud 2015; 52 (03) 677-685
- 19 Sitzmann JV, Townsend TR, Siler MC, Bartlett JG. Septic and technical complications of central venous catheterization. A prospective study of 200 consecutive patients. Ann Surg 1985; 202 (06) 766-770
- 20 Mansfield PF, Hohn DC, Fornage BD, Gregurich MA, Ota DM. Complications and failures of subclavian-vein catheterization. N Engl J Med 1994; 331 (26) 1735-1738
- 21 Kawai T, Andrews D, Colvin RB, Sachs DH, Cosimi AB. Thromboembolic complications after treatment with monoclonal antibody against CD40 ligand. Nat Med 2000; 6 (02) 114
- 22 Marquez A, Shabanova V, Faustino EVS. ; Northeast Pediatric Critical Care Research Consortium. Prediction of catheter-associated thrombosis in critically ill children. Pediatr Crit Care Med 2016; 17 (11) e521-e528
- 23 Leung A, Heal C, Perera M, Pretorius C. A systematic review of patient-related risk factors for catheter-related thrombosis. J Thromb Thrombolysis 2015; 40 (03) 363-373
- 24 Geerts W. Central venous catheter-related thrombosis. Hematology (Am Soc Hematol Educ Program) 2014; 2014 (01) 306-311
- 25 Bateman SL, Seed PC. Procession to pediatric bacteremia and sepsis: covert operations and failures in diplomacy. Pediatrics 2010; 126 (01) 137-150
- 26 Lidia Decembrino GR, D'angelo A, Decembrino N, Manzoni P, Boncimino A, Stronati M. Septic Shock in Neonates, Severe Sepsis and Septic Shock - Understanding a Serious Killer. In Tech; 2012