Facial Plast Surg 2003; 19(4): 331-340
DOI: 10.1055/s-2004-815653
Copyright © 2003 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA. Tel.: +1(212) 584-4662

Expanded Polytetrafluoroethylene Implants in Rhinoplasty: Literature Review, Operative Techniques, and Outcome

Jongwook Ham, Philip J. Miller
  • Division of Facial Plastic and Reconstructive Surgery, Department of Otolaryngology, New York University School of Medicine, New York, NY
Further Information

Publication History

Publication Date:
22 January 2004 (online)

ABSTRACT

Gore-Tex, a form of expanded polytetrafluoroethylene (ePTFE), over the past 30 years has attracted much attention as an alloplast for use in rhinoplasty, both from advocates and opponents of its use. It has many desirable traits as an alloplast implant, but many surgeons harbor hesitation and reluctance for alloplast use in rhinoplasty based on historical data of previous nasal implants. Only when objective data from large series of patients with long-term follow-up become available will such skepticism be resolved. Large series of patients with Gore-Tex implant placement during rhinoplasty are beginning to emerge in the literature. The purpose of this article is twofold. The first is to provide the reader with an up-to-date review of the literature on the host response to polymer implants and, second, of the current indications and operative techniques for use and outcomes of Gore-Tex implants in rhinoplasty.

REFERENCES

  • 1 Singh S, Baker J L. Use of expanded polytetrafluoroethylene in aesthetic surgery of the face.  Clin Plast Surg . 2000;  27(4) 579-593
  • 2 Schoenrock L D, Chernoff W G. Subcutaneous implantation of Gore-Tex for facial reconstruction.  Otolaryngol Clin North Am . 1995;  28(2) 325-340
  • 3 Schoenrock L D, Repucci A D. Correction of subcutaneous facial defects using Gore-Tex.  Facial Plast Surg Clin North Am . 1994;  2(3) 373-387
  • 4 Hanel K C, McCabe C, Abbott W M, Fallon J, Megerman J. Current PTFE grafts.  Ann Surg . 1982;  195(4) 456-463
  • 5 Conrad K, Gillman G. A 6-year experience with the use of expanded polytetrafluoroethylene in rhinoplasty.  Plast Reconstr Surg . 1998;  101(6) 1675-1683
  • 6 Cohen M S, Constantino P D, Friedman C D. Biology of implants used in head and neck surgery.  Facial Plast Surg Clin North Am . 1999;  7(1) 17-33
  • 7 Karesh J W, Fabrega M A, Rodrigues M M, Glaros D S. Polytetrafluoroethylene as an interpositional graft material for the correction of lower eyelid retraction.  Ophthalmology . 1989;  96(4) 419-423
  • 8 Tang L, Eaton J W. Inflammatory responses to biomaterials.  Am J Clin Pathol . 1995;  103(4) 466-471
  • 9 Morehead J M, Holt G R. Soft-tissue response to synthetic biomaterials.  Otolaryngol Clin North Am . 1994;  27(1) 195-201
  • 10 Rubin J P, Yaremchuk M J. Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery: a comprehensive review of the literature.  Plast Reconstr Surg . 1997;  100(5) 1336-1353
  • 11 Merritt K, Shafer J W, Brown S A. Implant site infection rates with porous and dense materials.  J Biomed Mater Res . 1979;  13 101-108
  • 12 Kiechel S F, Rodeheaver G T, Klawitter J J, Edgerton M T, Edlich R F. The role of implant porosity on the development of infection.  Surg Gynecol Obstet . 1977;  144 58-62
  • 13 Karlan M S, Mufson R A, Grizzard M B, Buscemi P A, Hench L, Goldberg E P. Potentiation of infections by biomaterials: a comparison of three materials.  Otolaryngol Head Neck Surg . 1981;  89 528-534
  • 14 Bauer J J, Salky B A, Gelernt I M, Kreel I. Repair of large abdominal wall defects with expanded polytetrafluoroethylene (PTFE).  Ann Surg . 1987;  206(6) 765-769
  • 15 Maas C S, Gnepp D R, Bumpous J. Expanded polytetrafluoroethylene (Gore-Tex soft-tissue patch) in facial augmentation.  Arch Otolaryngol Head Neck Surg . 1993;  119 1008-1014
  • 16 Neel H B. Implants of Gore-Tex.  Arch Otolaryngol . 1983;  109 427-433
  • 17 Petroff M A, Goode R L, Levet Y. Gore-Tex implants: applications in facial paralysis rehabilitation and soft-tissue augmentation.  Laryngoscope . 1992;  102 1185-1189
  • 18 Rothstein S G, Jacobs J B. The use of Gore-Tex implants in nasal augmentation operations.  ENTechnology . 1989;  40,42 40-45
  • 19 Stoll W. The use of polytetrafluoroethylene for particular augmentation of the nasal dorsum.  Aesth Plast Surg . 1991;  15 233-236
  • 20 Owsley T G, Taylor C O. The use of Gore-Tex for nasal augmentation: a retrospective analysis of 106 patients.  Plast Reconstr Surg . 1994;  94(2) 241-248
  • 21 Queen T A, Palmer F R. Gore-Tex for nasal augmentation: a recent series and a review of the literature.  Ann Otolaryngol Rhinol Laryngol . 1995;  104 850-852
  • 22 Mendelsohn M, Dunlop G. Gore-Tex augmentation grafting in rhinoplasty-is it safe?.  J Otolaryngol . 1998;  27(6) 337-341
  • 23 Lohuis P, Watts S J, Vuyk H D. Augmentation of the nasal dorsum using Gore-Tex: intermediate results of a retrospective analysis of experience in 66 patients.  Clin Otolaryngol . 2001;  26 214-217
  • 24 Godin M, Waldman S R, Johnson C M. Nasal augmentation using Gore-Tex: a 10 year experience.  Arch Facial Plast Surg . 1999;  1 118-121
  • 25 Waldman S R. Gore-Tex for augmentation of the nasal dorsum: a preliminary report.  Ann Plast Surg . 1991;  26(6) 520-525
  • 26 Godin M S, Waldman S R, Johnson C M. The use of expanded polytetrafluoroethylene (Gore-Tex) in rhinoplasty: a 6-year experience.  Arch Otolaryngol Head Neck Surg . 1995;  121 1131-1136
  • 27 Herbst A. Extrusion of an expanded polytetrafluoroethylene implant after rhinoplasty (correspondence).  Plast Reconstr Surg . 1999;  104 295-296
  • 28 Johnson C M. The Radix graft in cosmetic rhinoplasty (commentary).  Arch Facial Plast Surg . 2001;  3 120-121
    >