CC BY-NC-ND 4.0 · European Journal of General Dentistry 2019; 8(01): 18-22
DOI: 10.4103/ejgd.ejgd_136_18
Original Article

Marginal adaptation of implant ceramic crowns produced with cerec® system

Silvio Mecca Jr
São Leopoldo Mandic Dental Research Center, Campinas, São Paulo, Brazil
,
Elimário Venturin Ramos
São Leopoldo Mandic Dental Research Center, Campinas, São Paulo, Brazil
,
Geraldo Alberto Pinheiro Carvalho
São Leopoldo Mandic Dental Research Center, Campinas, São Paulo, Brazil
,
Simone Kreve
São Leopoldo Mandic Dental Research Center, Campinas, São Paulo, Brazil
,
Aline Batista Gonçalves Franco
São Leopoldo Mandic Dental Research Center, Campinas, São Paulo, Brazil
,
Sergio Candido Dias
São Leopoldo Mandic Dental Research Center, Campinas, São Paulo, Brazil
› Author Affiliations
 

Abstract

Aim: This study aimed to assess the marginal adaptation of two different ceramic materials produced with CEREC system. Materials and Methods: A master die was digitized with an intraoral scanner (CEREC Omnicam) and produced 20 lithium silicate crowns – 10 VITA Suprinity® (VS) and 10 Celtra Duo® (CD). Marginal disadaptation was measured using the replica method and optical microscopy. Results: The Student’s t-test showed a significant difference (P < 0.05) between VS (63.65 μm) and CD (97.05 μm). Results also showed statistical difference within the CD group (P < 0.005); on the other hand, there was no significant difference within the VS group. Conclusion: Based on the methodology used here, we are able to conclude that the VS group shows less marginal disadaptation and that, in addition to a larger marginal discrepancy, the CD crowns failed to maintain homogeneity since samples varied largely within the group.


#

Introduction

Marginal adaptation has always been one of the major concerns regarding dental prosthesis.[[1]] The presence of a marginal space between the dental pieces promotes cementing agent dissolution,[[1]],[[2]] leading to biofilm accumulation, which in turn, results in cavities[[3]] and periodontal disease. The optimal placement of pieces, avoiding spacings, contributes to clinical success and treatment longevity. The crown is well adapted when the gap is not visually noticeable or when the clinical probe fails to detect it. Acceptable gaps range between 100 and 120 μm.[[4]],[[5]],[[6]]

Disadaptation or marginal discrepancy is defined as the distance between the crown edge and the finish line.[[3]],[[5]],[[7]]

With the advent of computer-aided design/computer-aided manufacturing (CAD/CAM) system and other new technology, better outcomes were obtained regarding the accuracy and piece adaptation since their preparations are not dependent on the laboratory’s technical capacity.[[6]],[[8]],[[9]],[[10]],[[11]]

Digital moldings have shown several benefits in comparison to conventional dental material such as better patient acceptance, lack of distortions,[[7]] tridimensional preview of preparation, and better use of clinical time.[[9]],[[10]],[[12]] Digital techniques are often used for measuring the accuracy of fixed dental restorations because they are relatively accurate and their use does not cause the destruction of the sample. However, it necessary to considered that the angle at which the object is observed affects the accuracy of the measurement.[[7]]

Premanufactured crystal reinforced porcelain blocks are carefully and precisely machined by CAD/CAM systems. These crystals significantly increase piece resistance and have become increasingly common in clinical practice. However, whether these restorations can be compared to the laboratory-produced conventional restorations is yet to be shown.[[13]],[[14]]

Studies on the marginal adaptation of CAD/CAM machined pieces and the new materials used for digital dentistry are essential to provide information on the crowns clinical longevity.

The aim of this study was to assess the marginal adaptation of CAD/CAM-designed crowns in two different zirconia-reinforced lithium silicate (VITA Suprinity® and CELTRA DUO®).


#

Materials and Methods

This study was approved by the Ethics Committee of the School of Dentistry and Center for Dental Research São Leopoldo Mandic under the process number 2015/0484.

The initial master model used an anatomical abutment Straumann® IPS e-max® (Straumann®, Basel, Switzerland), with 5.5 mm of height and platform of 4.8 mm tilted by 6° and axial wall and chamfer finish. The same abutment was attached to a Bone Level RC implant analog with 4.1 mm of diameter (Straumann®, Basel, Switzerland).

The die was digitized with the intraoral scanner Omnicam (SironaCompany, Bensheim, Germany). The virtual crown was designed using software CAD CEREC 4.4.4 (SironaCompany, Bensheim, Germany) and spacings of 90 μm [[Figure 1]].[[4]],[[15]]

Zoom Image
Figure 1: Digitized anatomical abutment and virtual crown design

The physical crowns were machined by the milling cutter MCXL (SironaCompany, Bensheim, Germany). To this end, we used two types of precrystallized zirconia-reinforced lithium silicate blocks VITA Suprinity® (Vita Zahnfabrik, Sackingen, Germany) and CELTRA DUO® (Dentsply-Sirona, Bensheim, Germany). Ten test specimens of each material were built, totaling 20 specimens. To assure machining standardization, each group used a pair of drills, and filters and cooling fluid as per recommended by the manufacturer. We then proceeded to test the crowns on the abutment [[Figure 2]].

Zoom Image
Figure 2: Crowns test on the abutment

Crown adaptation was measured using the replica method.[[2]]

The ensemble abutment analog was fixated in a Bioart B2 liner (Bioart Equipamentos Odontológicos Ltda, São Carlos; Brazil) and inserted into a bipartite acrylic box containing, in one half, heavy addition silicone Take 1 Advanced (Kerr Dental, Munich, Germany) for the confirmation of the positioning mold. Vestibular, lingual, mesial, and distal faces were marked, and silicone was insulated with lubricant K-Y Gel (Johnson and Johnson, New Jersey, USA).

The crown was cemented on the abutment using light silicone Take 1 Advanced (Kerr Dental, Munich, Germany) and repositioned on the heavy silicone mold with a 20N load on the liner for 5 min for silicone polymerization. The abutment was removed [[Figure 3]], and the corresponding spacing was filled with extra light Take 1 Advance Monophase (Kerr Dental, Munich, Germany). The second half of the box was filled with heavy silicone and repositioned to obtain the abutment replica in fluid silicone [[Figure 4]].

Zoom Image
Figure 3: Positioning of the ensemble crown abutment
Zoom Image
Figure 4: Confirmation of the abutment replica

The replica was covered in medium addition silicone Take 1 Advanced mono/medium (Kerr Dental, Munich, Germany) and, following its polymerization, was covered in heavy silicone, forming a replica of the complex abutment-cement-crown. This replica was evenly sliced into four parts, and measurements of the silicone layer relative to the cement line were taken in four points (mesial, distal, vestibular, and lingual) using an optical microscope Mitutoyo TM500 (Mitutoyo, Tokio, Japan) with ×30 magnification [[Figure 5]].

Zoom Image
Figure 5: Finished replicas

#

Results

To assess the materials disadaptation (VITA Suprinity®, Germany; CELTRA DUO®, Dentsply-Sirona, Germany), we used Student’s t-test for independent samples. For intragroup disadaptation, we used paired Student’s t-test.

Statistical calculations were done using SPSS 20 (IBM®, SPSS Inc., Chicago, IL, USA), with a significance level of 5%.

Student’s t-test for independent samples showed that the average marginal disadaptation within the VITA Suprinity® group, 63.65 (±7.81) μm, was significantly lower than that obtained for Celtra DUO®, 97.05 (±13.65 μm) (P < 0.05), as shown in [[Figure 6]].

Zoom Image
Figure 6: Comparative diagram of marginal disadaptation (um) of test specimens VITA Suprinity® and CELTRA DUO®

Student’s t-test for paired samples showed higher correlation coefficients of disadaptation measurements for the Celtra DUO® group (P < 0.05), with marginal discrepancy values varying between 76 μm and 140 μm within the same group [[Table 1]].

Table 1:

Marginal disadaptation results (mm) for Celtra DUO® test specimens (paired Student's t-test = P < 0.05)

Specimens

Celtra DUO®

Buccal

Lingual

Mesial

Distal

Mean

C1

0.0800

0.0760

0.0840

0.0920

0.0830

C2

0.0970

0.1030

0.0980

0.0930

0.0978

C3

0.0830

0.0790

0.0900

0.0830

0.0838

C4

0.1210

0.1080

0.1010

0.1200

0.1125

C5

0.1030

0.1000

0.0980

0.1060

0.1018

C6

0.0880

0.0860

0.0850

0.0930

0.0880

C7

0.0930

0.0970

0.0930

0.0990

0.0955

C8

0.0990

0.1070

0.1030

0.0980

0.1018

C9

0.0760

0.0880

0.0810

0.0970

0.0855

C10

0.1090

0.1150

0.1200

0.1400

0.1210

Mean

0.09705 (mm)

However, paired Student’s t-test results for VITA Suprinity® showed nonsignificant correlation coefficients (P > 0.05), with marginal discrepancy values varying from 51 μm to 79 μm within the same group [[Table 2]].

Table 2:

Marginal discrepancy results (mm) for VITA Suprinity ® test specimens (paired Student's t-test = P > 0.05)

Specimens

VITA suprinity®

Buccal

Lingual

Mesial

Distal

Mean

C1

0.0790

0.0630

0.0740

0.0710

0.0718

C2

0.0660

0.0640

0.0690

0.0610

0.0650

C3

0.0700

0.0780

0.0730

0.0690

0.0725

C4

0.0790

0.0750

0.0710

0.0680

0.0732

C5

0.0530

0.0580

0.0620

0.0610

0.0585

C6

0.0510

0.0560

0.0580

0.0610

0.0565

C7

0.0670

0.0710

0.0620

0.0680

0.0670

C8

0.0550

0.0520

0.0610

0.0520

0.0550

C9

0.0570

0.0590

0.0550

0.0610

0.0580

C10

0.0590

0.0610

0.0630

0.0530

0.0590

Mean

0.06365 (mm)


#

Discussion

Digital dentistry is becoming a reality, and chairside systems will soon occupy the dental office. With this technological advancement in consideration, this study aims to assess the vertical marginal discrepancy of porcelain crowns. According to Jacobs and Windeler,[[4]] this is a critical factor to the success of the clinical treatment. The author sought to identify the amount of marginal disadaptation that would lead to failure in prosthetic treatment and showed that spacings above 120 μm increase the likelihood of failure due to plaque accumulation and the resulting decalcification of the tooth structure.

Here, we used an anatomical abutment Straumann® IPS e-max® as master model, chosen based on studies that show that chamfer finished preparations result in smaller marginal disadaptation for ceramic crowns.[[3]],[[16]],[[17]] On the other hand, other studies failed to find significant differences in marginal disadaptation between chamfer finish, shoulder, and round shoulder preparations.[[6]]

The master model was digitized using an Omnicam intraoral scanner. Studies show that the digital method is advantageous in comparison with the conventional modeling since it is standardized and streamlines the clinical workflow.[[9]] It is also faster and avoids repetitions.[[12]],[[18]] On the other hand, some studies have shown more precise results for conventional molding, suggesting that they outperform the digital alternative regarding fidelity and precision.[[19]] However, some works have shown precision in internal and marginal adaptation, without significant difference between digital and conventional molding.[[20]],[[21]]

We used the software CAD CEREC 4.4.4 to design the virtual crown, using 90 μm of cement spacing, as per the study of Prudente et al.[[8]] which used 80 μm of spacing according to the manufacturer’s recommendations. It has been shown that a larger cement spacing affects marginal adaptation of ceramic crowns.[[1]],[[22]] Particularly, Mously et al.[[23]] have shown smaller vertical disadaptations with spacings of 100 μm. Regarding the resin cement thickness, Molin et al.[[2]] observed that a variation in thickness in the range of 50–100 μm optimizes performance and resistance of the adhesion interface or line. It is worth mentioning that our spacing parameter was chosen based on Kim et al.[[24]] as well, which observed a 10 μm increase in average marginal disadaptation after crown crystallization. Here, the crowns were analyzed in the precrystallization stage.

The lithium silicate crowns were machined on a MCXL milling cutter (Sirona Company, Germany), a 4-axis equipment used in office environment, as per the studies by Hamza and Sherif[[25]] who assessed several milling cutters and concluded that the marginal disadaptation found were clinically acceptable.

For the vertical discrepancy assessment, we used the replica method, supported by several authors[[3]],[[5]],[[15]],[[26]],[[27]] and particularly by Trifkovic et al.[[7]] who concluded that this method improves the possibility of verifying disadaptation and offers more precise results relative to other techniques.

Here, we used precrystallized zirconia-reinforced lithium silicate from two commercial brands (VITA Suprinity®, Germany; CELTRA DUO, Dentsply-Sirona, Germany). Suprinity® has been shown to have low probability of clinical failure due to its superior mechanical properties when compared to IPS e.max CAD.[[14]] When compared to each other, both Suprinity® and CELTRA DUO® present great performance with a very low failure rate.[[28]] They also present similar flexural strength CELTRA DUO® with 626.84 MPa and Suprinity® with 611.24 MPa[[8]] and microstructure.[[29]]

In this study, the VITA Suprinity® group showed marginal disadaptation values of 63.65 μm, significantly smaller than those found in the CELTRA DUO® group – with 97.05 μm (P < 0.05), both values clinically acceptable. These results are similar to those showing smaller marginal disadaptation values in comparison to the conventional method, suggesting that overall CAD/CAM technology is advantageous.[[9]],[[26]],[[30]] Notwithstanding, some authors have shown that conventional copings and CAD/CAM adaptation are very similar,[[5]],[[31]] while others observed significantly larger internal discrepancies in CAD-/CAM-produced crowns.[[23]],[[27]]

Here, we show a significant difference in marginal disadaptation between microstructurally similar materials. In CELTRA DUO® group, the results were higher than those showed in Suprinity® group. In addition to that, the marginal disadaptation within the CELTRA DUO® group showed high correlation coefficients, with a range of marginal discrepancy of 76 μm–140 μm. This lack of homogeneity can be explained by the material’s machinability, i.e., its ability to be machined without harming its mechanical properties or burring and factors that affect marginal adaptation. Chavali et al.[[32]] corroborated this finding when they compared the milling cutter rate of penetration between the hybrid materials LAVA Ultimate (3M) and Enamic (VITA), and the ceramic materials E-max and CELTRA DUO®, obtaining smaller machinability rates for CELTRA DUO®, with 0.80 mm/min. Elsaka and Elnaghy[[14]] also observed larger hardness values in zirconia-reinforced lithium silicate, another factor that explains its smaller machinability.


#

Conclusion

Based on the methods used and the results obtained, it can be concluded that there are significant differences in the values of marginal misfit between the two materials. VITA Suprinity® lithium silicate crowns showed better performance with lower marginal discrepancy values (63.65 ± 7.81 μm). The CELTRA DUO® lithium silicate crowns, in addition to presenting higher marginal discrepancy values (97.05 ± 13.65 μm), also showed an inconsistency in the results since the values of misfit varied greatly within the group (from 76 μm to 140 μm). The VITA Suprinity® group presented more homogeneous results within its group with little variation of marginal discrepancy values (from 51 μm to 79 μm).

In this study, the null hypothesis was not accepted because there was a significant difference (P < 0.05) in the results of the marginal misadaptation of the VITA Suprinity® and CELTRA DUO® ceramic crowns.


#
Staying in touch with the journal
  • 1) Table of Contents (TOC) email alert

    Receive an email alert containing the TOC when a new complete issue of the journal is made available online. To register for TOC alerts go to www.ejgd.org/signup.asp .

  • 2) RSS feeds

    Really Simple Syndication (RSS) helps you to get alerts on new publication right on your desktop without going to the journal's website. You need a software (e.g. RSSReader, Feed Demon, FeedReader, My Yahoo!, NewsGator and NewzCrawler) to get advantage of this tool. RSS feeds can also be read through FireFox or Microsoft Outlook 2007. Once any of these small (and mostly free) software is installed, add www.ejgd.org/rssfeed.asp as one of the feeds.


#

Conflict of Interest

There are no conflicts of interest.

Financial support and sponsorship

Nil.


  • References

  • 1 Nakamura T, Dei N, Kojima T, Wakabayashi K. Marginal and internal fit of cerec 3 CAD/CAM all-ceramic crowns. Int J Prosthodont 2003;16:244-8.
  • 2 Molin MK, Karlsson SL, Kristiansen MS. Influence of film thickness on joint bend strength of a ceramic/resin composite joint. Dent Mater 1996;12:245-9.
  • 3 Souza RO, Özcan M, Pavanelli CA, Buso L, Lombardo GH, Michida SM, et al. Marginal and internal discrepancies related to margin design of ceramic crowns fabricated by a CAD/CAM system. J Prosthodont 2012;21:94-100.
  • 4 Jacobs MS, Windeler AS. An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 1991;65:436-42.
  • 5 Colpani JT, Borba M, Della Bona A. Evaluation of marginal and internal fit of ceramic crown copings. Dent Mater 2013;29:174-80.
  • 6 Subasi G, Ozturk N, Inan O, Bozogullari N. Evaluation of marginal fit of two all-ceramic copings with two finish lines. Eur J Dent 2012;6:163-8.
  • 7 Trifkovic B, Budak I, Todorovic A, Hodolic J, Puskar T, Jevremovic D, et al. Application of replica technique and SEM in accuracy measurement of ceramic crowns. Meas Sci Rev 2012;12:90-7.
  • 8 Prudente MS, Davi LR, Nabbout KO, Prado CJ, Pereira LM, Zancopé K, et al. Influence of scanner, powder application, and adjustments on CAD-CAM crown misfit. J Prosthet Dent 2018;119:377-83.
  • 9 Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 2013;17:1759-64.
  • 10 Lee KB, Park CW, Kim KH, Kwon TY. Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems. Dent Mater J 2008;27:422-6.
  • 11 Neves FD, Prado CJ, Prudente MS, Carneiro TA, Zancopé K, Davi LR, et al. Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique. J Prosthet Dent 2014;112:1134-40.
  • 12 Lee SJ, Gallucci GO. Digital vs. conventional implant impressions: Efficiency outcomes. Clin Oral Implants Res 2013;24:111-5.
  • 13 Wendler M, Belli R, Petschelt A, Mevec D, Harrer W, Lube T, et al. Chairside CAD/CAM materials. Part 2: Flexural strength testing. Dent Mater 2017;33:99-109.
  • 14 Elsaka SE, Elnaghy AM. Mechanical properties of zirconia reinforced lithium silicate glass-ceramic. Dent Mater 2016;32:908-14.
  • 15 Tamim H, Skjerven H, Ekfeldt A, Rønold HJ. Clinical evaluation of CAD/CAM metal-ceramic posterior crowns fabricated from intraoral digital impressions. Int J Prosthodont 2014;27:331-7.
  • 16 Ates SM, Yesil Duymus Z. Influence of tooth preparation design on fitting accuracy of CAD-CAM based restorations. J Esthet Restor Dent 2016;28:238-46.
  • 17 Kane LM, Chronaios D, Sierraalta M, George FM. Marginal and internal adaptation of milled cobalt-chromium copings. J Prosthet Dent 2015;114:680-5.
  • 18 Yuzbasioglu E, Kurt H, Turunc R, Bilir H. Comparison of digital and conventional impression techniques: Evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health 2014;14:10.
  • 19 Ender A, Mehl A. Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision. J Prosthet Dent 2013;109:121-8.
  • 20 Rödiger M, Heinitz A, Bürgers R, Rinke S. Fitting accuracy of zirconia single crowns produced via digital and conventional impressions – A clinical comparative study. Clin Oral Investig 2017;21:579-87.
  • 21 Boeddinghaus M, Breloer ES, Rehmann P, Wöstmann B. Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig 2015;19:2027-34.
  • 22 Kale E, Seker E, Yilmaz B, Özcelik TB. Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns. J Prosthet Dent 2016;116:890-5.
  • 23 Mously HA, Finkelman M, Zandparsa R, Hirayama H. Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique. J Prosthet Dent 2014;112:249-56.
  • 24 Kim JH, Jeong JH, Lee JH, Cho HW. Fit of lithium disilicate crowns fabricated from conventional and digital impressions assessed with micro-CT. J Prosthet Dent 2016;116:551-7.
  • 25 Hamza TA, Sherif RM. in vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems. J Prosthet Dent 2017;117:762-6.
  • 26 Shamseddine L, Mortada R, Rifai K, Chidiac JJ. Marginal and internal fit of pressed ceramic crowns made from conventional and computer-aided design and computer-aided manufacturing wax patterns: An in vitro comparison. J Prosthet Dent 2016;116:242-8.
  • 27 Guess PC, Vagkopoulou T, Zhang Y, Wolkewitz M, Strub JR. Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue. J Dent 2014;42:199-209.
  • 28 Zimmermann M, Egli G, Zaruba M, Mehl A. Influence of material thickness on fractural strength of CAD/CAM fabricated ceramic crowns. Dent Mater J 2017;36:778-83.
  • 29 Belli R, Wendler M, de Ligny D, Cicconi MR, Petschelt A, Peterlik H, et al. Chairside CAD/CAM materials. Part 1: Measurement of elastic constants and microstructural characterization. Dent Mater 2017;33:84-98.
  • 30 Freire Y, Gonzalo E, Lopez-Suarez C, Suarez MJ. The marginal fit of CAD/CAM monolithic ceramic and metal-ceramic crowns. J Prosthodont 2017. p. 1-6.
  • 31 Gunsoy S, Ulusoy M. Evaluation of marginal/internal fit of chrome-cobalt crowns: Direct laser metal sintering versus computer-aided design and computer-aided manufacturing. Niger J Clin Pract 2016;19:636-44.
  • 32 Chavali R, Nejat AH, Lawson NC. Machinability of CAD-CAM materials. J Prosthet Dent 2017;118:194-9.

Address for correspondence

Prof. Simone Kreve
Rua Independencia 1899, Apto 602, Centro, Toledo, Parana
Brazil   

Publication History

Article published online:
01 November 2021

© 2019. European Journal of General Dentistry. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

  • References

  • 1 Nakamura T, Dei N, Kojima T, Wakabayashi K. Marginal and internal fit of cerec 3 CAD/CAM all-ceramic crowns. Int J Prosthodont 2003;16:244-8.
  • 2 Molin MK, Karlsson SL, Kristiansen MS. Influence of film thickness on joint bend strength of a ceramic/resin composite joint. Dent Mater 1996;12:245-9.
  • 3 Souza RO, Özcan M, Pavanelli CA, Buso L, Lombardo GH, Michida SM, et al. Marginal and internal discrepancies related to margin design of ceramic crowns fabricated by a CAD/CAM system. J Prosthodont 2012;21:94-100.
  • 4 Jacobs MS, Windeler AS. An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 1991;65:436-42.
  • 5 Colpani JT, Borba M, Della Bona A. Evaluation of marginal and internal fit of ceramic crown copings. Dent Mater 2013;29:174-80.
  • 6 Subasi G, Ozturk N, Inan O, Bozogullari N. Evaluation of marginal fit of two all-ceramic copings with two finish lines. Eur J Dent 2012;6:163-8.
  • 7 Trifkovic B, Budak I, Todorovic A, Hodolic J, Puskar T, Jevremovic D, et al. Application of replica technique and SEM in accuracy measurement of ceramic crowns. Meas Sci Rev 2012;12:90-7.
  • 8 Prudente MS, Davi LR, Nabbout KO, Prado CJ, Pereira LM, Zancopé K, et al. Influence of scanner, powder application, and adjustments on CAD-CAM crown misfit. J Prosthet Dent 2018;119:377-83.
  • 9 Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 2013;17:1759-64.
  • 10 Lee KB, Park CW, Kim KH, Kwon TY. Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems. Dent Mater J 2008;27:422-6.
  • 11 Neves FD, Prado CJ, Prudente MS, Carneiro TA, Zancopé K, Davi LR, et al. Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique. J Prosthet Dent 2014;112:1134-40.
  • 12 Lee SJ, Gallucci GO. Digital vs. conventional implant impressions: Efficiency outcomes. Clin Oral Implants Res 2013;24:111-5.
  • 13 Wendler M, Belli R, Petschelt A, Mevec D, Harrer W, Lube T, et al. Chairside CAD/CAM materials. Part 2: Flexural strength testing. Dent Mater 2017;33:99-109.
  • 14 Elsaka SE, Elnaghy AM. Mechanical properties of zirconia reinforced lithium silicate glass-ceramic. Dent Mater 2016;32:908-14.
  • 15 Tamim H, Skjerven H, Ekfeldt A, Rønold HJ. Clinical evaluation of CAD/CAM metal-ceramic posterior crowns fabricated from intraoral digital impressions. Int J Prosthodont 2014;27:331-7.
  • 16 Ates SM, Yesil Duymus Z. Influence of tooth preparation design on fitting accuracy of CAD-CAM based restorations. J Esthet Restor Dent 2016;28:238-46.
  • 17 Kane LM, Chronaios D, Sierraalta M, George FM. Marginal and internal adaptation of milled cobalt-chromium copings. J Prosthet Dent 2015;114:680-5.
  • 18 Yuzbasioglu E, Kurt H, Turunc R, Bilir H. Comparison of digital and conventional impression techniques: Evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health 2014;14:10.
  • 19 Ender A, Mehl A. Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision. J Prosthet Dent 2013;109:121-8.
  • 20 Rödiger M, Heinitz A, Bürgers R, Rinke S. Fitting accuracy of zirconia single crowns produced via digital and conventional impressions – A clinical comparative study. Clin Oral Investig 2017;21:579-87.
  • 21 Boeddinghaus M, Breloer ES, Rehmann P, Wöstmann B. Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig 2015;19:2027-34.
  • 22 Kale E, Seker E, Yilmaz B, Özcelik TB. Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns. J Prosthet Dent 2016;116:890-5.
  • 23 Mously HA, Finkelman M, Zandparsa R, Hirayama H. Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique. J Prosthet Dent 2014;112:249-56.
  • 24 Kim JH, Jeong JH, Lee JH, Cho HW. Fit of lithium disilicate crowns fabricated from conventional and digital impressions assessed with micro-CT. J Prosthet Dent 2016;116:551-7.
  • 25 Hamza TA, Sherif RM. in vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems. J Prosthet Dent 2017;117:762-6.
  • 26 Shamseddine L, Mortada R, Rifai K, Chidiac JJ. Marginal and internal fit of pressed ceramic crowns made from conventional and computer-aided design and computer-aided manufacturing wax patterns: An in vitro comparison. J Prosthet Dent 2016;116:242-8.
  • 27 Guess PC, Vagkopoulou T, Zhang Y, Wolkewitz M, Strub JR. Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue. J Dent 2014;42:199-209.
  • 28 Zimmermann M, Egli G, Zaruba M, Mehl A. Influence of material thickness on fractural strength of CAD/CAM fabricated ceramic crowns. Dent Mater J 2017;36:778-83.
  • 29 Belli R, Wendler M, de Ligny D, Cicconi MR, Petschelt A, Peterlik H, et al. Chairside CAD/CAM materials. Part 1: Measurement of elastic constants and microstructural characterization. Dent Mater 2017;33:84-98.
  • 30 Freire Y, Gonzalo E, Lopez-Suarez C, Suarez MJ. The marginal fit of CAD/CAM monolithic ceramic and metal-ceramic crowns. J Prosthodont 2017. p. 1-6.
  • 31 Gunsoy S, Ulusoy M. Evaluation of marginal/internal fit of chrome-cobalt crowns: Direct laser metal sintering versus computer-aided design and computer-aided manufacturing. Niger J Clin Pract 2016;19:636-44.
  • 32 Chavali R, Nejat AH, Lawson NC. Machinability of CAD-CAM materials. J Prosthet Dent 2017;118:194-9.

Zoom Image
Figure 1: Digitized anatomical abutment and virtual crown design
Zoom Image
Figure 2: Crowns test on the abutment
Zoom Image
Figure 3: Positioning of the ensemble crown abutment
Zoom Image
Figure 4: Confirmation of the abutment replica
Zoom Image
Figure 5: Finished replicas
Zoom Image
Figure 6: Comparative diagram of marginal disadaptation (um) of test specimens VITA Suprinity® and CELTRA DUO®