Gastrointestinal stromal tumors (GIST) are the most common mesenchymal tumors of the gastrointestinal tract. It has been debated whether the morbidity and mortality associated with surgery are acceptable when removing these lesions, which have a low potential for malignancy. Endoscopic submucosal dissection (ESD) enables en-bloc resection of such lesions regardless of their size and shape. However, ESD is associated with a risk of perforation of up to 5 %, depending on the size and location of the lesion. In order to maintain better visualization during ESD, the Fujinon FlushKnife (Fujinon, Willich, Germany) has been recently developed [1] [2] [3].
The case presented here involved a 58-year-old man with a gastric GIST ([Fig. 1]). Tumor resection was performed by means of FlushKnife ESD ([Fig. 2]) following submucosal injection of 30 ml saline containing epinephrine 1 : 10 000. GIST enucleation was performed endoscopically within 32 minutes. After ESD it became obvious that the gastric wall had been perforated, with air leakage and visible abdominal distension. Endoscopic full-thickness suturing of the perforation site was attempted to avoid surgical intervention ([Fig. 3] and [4], [Video 1]). The endoscopic suturing time was 12 minutes and an adequate suturing result was confirmed endoscopically. Enteral feeding was reestablished within 48 hours, and control gastroscopy at 72 hours after treatment confirmed complete closure of the perforation before the patient was discharged ([Fig. 5] and [6]).
The NDO Plicator device (NDO Surgical Inc., Mansfield, Massachusetts, USA), which enables endoscopic transmural suturing, was initially developed for the treatment of gastroesophageal reflux disease. Limited experience of using this device for closure of gastrointestinal wall defects has been reported elsewhere [4] [5] [6]. The resultant sealing is composed of the edges of the former defect bound with a nonabsorbable, pledgeted transmural suture ([Fig. 4]). A negative aspect of the transmural procedure is the risk of blindly incorporating or damaging adjacent organs. In addition, the risk of fistulation and migration of the nonresorbable pledgeted sutures is unknown at present. Nevertheless, the Plicator might be a useful endoscopic suturing device allowing surgical intervention to be avoided if perforation occurs.
Qualität:
Video 1 Perforation closure by means of endoscopic full-thickness suturing.
Endoscopy_UCTN_Code_CPL_1AH_2AZ
Endoscopy_UCTN_Code_CCL_1AB_2AD_3AB
#References
- 1 Hwang J H, Rulyak S D, Kimmey M B. American Gastroenterological Association Institute technical review on the management of gastric subepithelial masses. Gastroenterology. 2006; 7 2217-2228
- 2 Imagawa A, Okada H, Kawahara Y. et al . Endoscopic submucosal dissection for early gastric cancer: results and degrees of technical difficulty as well as success. Endoscopy. 2006; 38 987-990
- 3 Toyonaga T, Nishino E. Effectiveness of endoscopic submucosal dissection using flush knife for esophageal cancers. Gastrointest Endosc. 2007; 65 AB93
- 4 Renteln D von, Schmidt A, Riecken B, Caca K. Gastric full-thickness suturing during endoscopic mucosal resection and for treatment of gastric wall defects. Gastrointest Endosc. 2008; 67 738-744
- 5 Renteln D von, Kaehler G, Eickhoff A. et al . Gastric full-thickness suturing following NOTES procedures for closure of the access site to the peritoneal cavity. Endoscopy. 2008; 40 E1-E2
- 6 McGee M F, Marks J M, Jin J. et al . Complete endoscopic closure of gastric defects using a full-thickness tissue plicating device. J Gastrointest Surg. 2008; 12 38-45
D. von Renteln, MD
Department of Gastroenterology, Hepatology and Oncology
Klinikum Ludwigsburg
Teaching Hospital of the University of Heidelberg
Ludwigsburg
Germany
Fax: +49-7141-9967219
eMail: renteln@gmx.net
References
- 1 Hwang J H, Rulyak S D, Kimmey M B. American Gastroenterological Association Institute technical review on the management of gastric subepithelial masses. Gastroenterology. 2006; 7 2217-2228
- 2 Imagawa A, Okada H, Kawahara Y. et al . Endoscopic submucosal dissection for early gastric cancer: results and degrees of technical difficulty as well as success. Endoscopy. 2006; 38 987-990
- 3 Toyonaga T, Nishino E. Effectiveness of endoscopic submucosal dissection using flush knife for esophageal cancers. Gastrointest Endosc. 2007; 65 AB93
- 4 Renteln D von, Schmidt A, Riecken B, Caca K. Gastric full-thickness suturing during endoscopic mucosal resection and for treatment of gastric wall defects. Gastrointest Endosc. 2008; 67 738-744
- 5 Renteln D von, Kaehler G, Eickhoff A. et al . Gastric full-thickness suturing following NOTES procedures for closure of the access site to the peritoneal cavity. Endoscopy. 2008; 40 E1-E2
- 6 McGee M F, Marks J M, Jin J. et al . Complete endoscopic closure of gastric defects using a full-thickness tissue plicating device. J Gastrointest Surg. 2008; 12 38-45