Rofo 2004; 176(2): 157-162
DOI: 10.1055/s-2004-817622
Rapid Communication
© Georg Thieme Verlag Stuttgart · New York

Optimization of Contrast-Enhanced Peripheral MR Angiography with Mid-Femoral Venous Compression (VENCO)

Optimierung der Kontrastmittel-verstärkten MR-Angiographie der Becken-Bein-Strombahn durch venöse Kompression (VENCO) am OberschenkelC.  U.  Herborn1 , F.  M.  Vogt1 , K.-U.  Waltering1 , K.-B.  Reiter2 , H.-W.  Kniemeyer3 , J.  Barkhausen1
  • 1Department of Diagnostic and Interventional Radiology, University Hospital Essen, Essen, Germany
  • 2Department of Diagnostic and Interventional Radiology, Elisabeth-Hospital, Essen, Germany
  • 3Department of Vascular Surgery, Elisabeth-Hospital, Essen, Germany
Further Information

Publication History

Publication Date:
11 February 2004 (online)

Zusammenfassung

Ziel: Bestimmung der Bildqualität bei der dreidimensionalen Kontrastmittel-unterstützen Magnetresonanz-Angiographie (3D KM-MRA) der Becken-Bein-Gefäße unter Anwendung einer räumlich hochaufgelösten Sequenz in Kombination mit suprapoplitealer venöser Kompression im Vergleich zum Standard-Protokoll. Material und Methoden: 12 Patienten mit peripherer arterieller Verschlusskrankheit (8 Männer; Alter, 52 - 74 Jahre; Mittel 67,1 Jahre; 4 Frauen; Alter, 57 - 71 Jahre; Mittel 62,1 Jahre) wurden einmal mit dem Standard-MRA-Protokoll und mindestens 24 Stunden später ein weiteres Mal mit einem räumlich hochaufgelösten Protokoll in Kombination mit suprapoplitealer venöser Kompression (VENCO, 60 mm Hg) untersucht. Die Bildgebung wurde auf einem 1.5 T Ganzkörper-MR-Scanner (Magnetom Sonata®, Siemens Medical-Solutions, Erlangen) mit einer Becken-Bein-Spule und paramagnetischem Kontrastmittel (Gadodiamid, Omniscan®, Amersham, Oslo, Norwegen) durchgeführt. Signal-Rausch- und Kontrast-Rausch-Verhältnisse (SNR und CNR) wurden für sämtliche Untersuchungen berechnet. Die Bildqualität sowie die venöse Überlagerung wurden auf einer 5-Punkte Skala bestimmt. Statistische Signifikanz wurde bei einem p-Wert < 0,.05 festgelegt. Ergebnisse: Mittlere SNR- und CNR-Werte für die Unterschenkelarterien mit VENCO waren statistisch signifikant höher im Vergleich zu den Ergebnissen im Standard-Protokoll (66 ± 8 vs. 52 ± 11 bzw. 53 ± 9 vs. 41 ± 8; p < 0,01). Die Bildqualität mit VENCO (4,0 ± 0,2 vs. 3,4 ± 0,8; p < 0,05) und die Bestimmung der venösen Kontamination (3,5 ± 0,4 vs. 4,1 ± 0,9; p < 0.05) am Unterschenkel waren dem Standard-Protokoll signifikant überlegen. Schlussfolgerung: Die suprapopliteale venöse Kompression lässt sich einfach klinisch einsetzen und optimiert die Bildqualität im Bereich der Unterschenkelarterien bei der 3D KM-MRA der Becken-Bein-Gefäße.

Abstract

Purpose: To compare a standard protocol for contrast-enhanced three-dimensional magnetic resonance angiography (3D CE-MRA) of the lower extremities to a high spatial resolution protocol with venous compression (VENCO) at the mid-femoral level. Material and Methods: 12 patients with peripheral arterial occlusive disease (8-males; age range, 52 - 74 years; mean 67.1 years; 4 females; age range, 57 - 71 years; mean 62.1 years) were examined once with a standard MR angiography (MRA) protocol, and a second time with a high spatial resolution protocol in combination with mid-femoral venous compression (60 mm Hg) for the last two stations. All imaging was performed on a 1.5 T whole-body MR scanner (Magnetom Sonata®, Siemens Medical Solutions, Erlangen, Germany) using a dedicated coil and paramagnetic contrast agent (gadodiamide, Omniscan®, Amersham, Oslo, Norway). Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated and image quality as well as venous overlay were assessed on a five-point scale for both examinations. Statistical significance was established at p < 0.05. Results: Mean SNR and CNR values of the two lower stations with VENCO were statistically significantly higher in comparison to the standard protocol (66 ± 8 vs. 52 ± 11 and 53 ± 9 vs. 41 ± 8, respectively; p < 0.01). The same was true for overall image quality with VENCO (4.0 ± 0.2 vs. 3.4 ± 0.8; p < 0.05) and presence of venous overlay (3.5 ± 0.4 vs. 4.1 ± 0.9; p < 0.05), respectively. Conclusion: VENCO 3D CE-MRA is simple to put into practice and advances the performance of multi-station MRA strategies for assessment of the peripheral arterial vasculature.

References

  • 1 Ho V B, Choyke P L, Foo T K, Hood M N, Miller D L, Czum J M, Aisen A M. Automated bolus chase peripheral MR angiography: initial practical experiences and future directions of this work-in-progress.  J Magn Reson Imaging. 1999;  10 376-388
  • 2 Meaney J F, Ridgway J P, Chakraverty S, Robertson I, Kessel D, Radjenovic A, Kouwenhoven M, Kassner A, Smith M A. Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience.  Radiology. 1999;  211 59-67
  • 3 Sueyoshi E, Sakamoto I, Matsuoka Y, Ogawa Y, Hayashi H, Hashmi R, Hayashi K. Aortoiliac and lower extremity arteries: comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography.  Radiology. 1999;  210 683-688
  • 4 Rofsky N M, Adelman M A. MR angiography in the evaluation of atherosclerotic peripheral vascular disease.  Radiology. 2000;  214 325-338
  • 5 Ruehm S G, Hany T F, Pfammatter T, Schneider E, Ladd M, Debatin J F. Pelvic and lower extremity arterial imaging: diagnostic performance of three-dimensional contrast-enhanced MR angiography.  AJR Am J Roentgenol. 2000;  174 1127-1135
  • 6 Earls J P, DeSena S, Bluemke D A. Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation.  Radiology. 1998;  209 844-849
  • 7 Ho K Y, Leiner T, de Haan M W, Kessels A G, Kitslaar P J, van Engelshoven J M. Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography.  Radiology. 1998;  206 683-692
  • 8 Leiner T, Ho K Y, Nelemans P J, de Haan M W, van Engelshoven J M. Three-dimensional contrast-enhanced moving-bed infusion-tracking (MoBI-track) peripheral MR angiography with flexible choice of imaging parameters for each field of view.  J Magn Reson Imaging. 2000;  11 368-377
  • 9 Foo T K, Ho V B, Hood M N, Marcos H B, Hess S L, Choyke P L. High-spatial-resolution multistation MR imaging of lower-extremity peripheral vasculature with segmented volume acquisition: feasibility study.  Radiology. 2001;  219 835-841
  • 10 Baum R A, Rutter C M, Sunshine J H, Blebea J S, Blebea J, Carpenter J P, Dickey K W, Quinn S F, Gomes A S, Grist T M. et al . Multicenter trial to evaluate vascular magnetic resonance angiography of the lower extremity. American College of Radiology Rapid Technology Assessment Group.  JAMA. 1995;  274 875-880
  • 11 Shellock F G, Kanal E. Safety of magnetic resonance imaging contrast agents.  J Magn Reson Imaging. 1999;  10 477-484
  • 12 Maki J H, Wilson G J, Eubank W B, Hoogeveen R M. Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography.  J Magn Reson Imaging. 2002;  15 484-491
  • 13 Swan J S, Carroll T J, Kennell T W, Heisey D M, Korosec F R, Frayne R, Mistretta C A, Grist T M. Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels.  Radiology. 2002;  225 43-52
  • 14 Wentz K U, Frohlich J M, von Weymarn C, Patak M A, Jenelten R, Zollikofer C L. High-resolution magnetic resonance angiography of hands with timed arterial compression (tac-MRA).  Lancet. 2003;  361 49-50
  • 15 Ruehm S G, Zimny K, Debatin J F. Direct contrast-enhanced 3D MR venography.  Eur Radiol. 2001;  11 102-112

Dr. med. Christoph U. Herborn

Institut für Diagnostische und Interventionelle Radiologie Universitätsklinikum Essen

Hufelandstr. 55

45122 Essen

Germany

Phone: +49-201-723 1527

Fax: +49-201-723 1526

Email: christoph.herborn@uni-essen.de

    >