Subscribe to RSS
DOI: 10.1055/s-0038-1632533
Clinical, Radiographic and Histological Evaluation of the Plastic Spiked Washer in the Dog
Publication History
Received:12 September 1997
Accepted:11 November 1997
Publication Date:
10 February 2018 (online)
Summary
Plastic spiked washers and metal washers were implanted in the periarticular soft tissues of six joints in three experimental dogs. These dogs were followed clinically and radiographically over a 16 week time frame, at which time they were euthanatized and histological evaluation was obtained. Differences were not observed clinically nor radiographically between joints, nor between locations, with the different implant devices throughout the time frame investigated in the experimental dogs. Histological evaluation revealed a very minimal to mild, fundamentally identical inflammatory response to all of the implants in all of the specimens; however, in three specimens (plastic spiked washers), very infrequent lesions of a few randomly scattered microgranulomas, surrounded by a fibrous connective tissue envelope, were observed. The histological response of a limited inflammatory reaction was comparable to the positive controls using metal washers in the experimental dogs, despite the few microgranulomas observed. A clinical retrospective evaluation of 31 joints in 29 dogs from 1992 to 1996, in which a plastic spiked washer was implanted, also was performed. Long term follow up (mean 2.6 years) of 21 dogs in the clinical case series revealed no complications related to infection or a foreign-body reaction. Both the experimental and clinical studies supported the authors’ impression that the plastic spiked washer is well tolerated over the long term.
A 16 week experimental study was performed in three dogs (six joints) in order to evaluate if any clinical, radiographic or histological differences could be found in the periarticular soft tissues with implantation of either a plastic spiked washer or a metal washer. No differences were observed clinically or radiographically between joints, or between locations, with the different implants. Histological evaluation revealed a very minimal to mild inflammatory response to all of the implants; however, a few very infrequent and randomly scattered microgranulomas were observed in response to the plastic spiked washers.
-
REFERENCES
- 1 Bloomberg M. Muscles and Tendons. In Textbook of Small Animal Surgery.. Slatter D. (ed). Philadelphia: W. B. Saunders; 1993: 1996-2020.
- 2 Boudrieau RJ, Hohn RB, Bardet JF. Osteochondritis dissecans of the elbow in the dog. J Am Anim Hosp Assoc 1983; 19: 627-35.
- 3 Parker RB, Schubert TA. Repair of ligamentous joint injuries in three dogs using spiked washers. J Am Anim Hosp Assoc 1981; 17: 45-50.
- 4 Shires PK, Hulse DA, Liu W. The underand- over fascial replacement technique for anterior cruciate ligament rupture in dogs: a retrospective study. J Am Anim Hosp Assoc 1984; 20: 69-77.
- 5 Roush JK, Kirby BM, Manley PA. et al. Chronic osteomyelitis associated with orthopedic implants and cranial cruciate repair in three dogs. J Am Vet Med Assoc 1990; 196: 1123-6.
- 6 Wolter D, Burri C, Kinzl L. et al. Die Veranderungen der physikalischen Eigenschaften von Polyacetalharz (Hostaform C), Polyester (Hostadur), Polyathylen (Hostalen), und Teflon (Hostaflon) nach tierischer Implantation und mehrfachem Autoklavieren. Arch Orthop Unfall-Chir 1976; 86: 291-302.
- 7 Hulse DA, Shires PK. The stifle joint. In Textbook of Small Animal Surgery. Slatter D. (ed). Philadelphia: W. B. Saunders; 1985: 2193-235.
- 8 Müller ME. Allgower M. Schneider R. et al (eds.). Manual of Internal Fixation. 2nd ed. New York: Springer-Verlag; 1979
- 9 Tang L, Eaton JW. Inflammatory responses to biomaterials. Am J Clin Pathol 1995; 103: 466-71.
- 10 Fister JS, Memoli VA, Galante JO. et al. Biocompatibility of Delrin 150: a creepresistant polymer for total joint prostheses. J Biomed Mater Res 1985; 19: 519-33.
- 11 Rae T. Localized tissue infection and the influence of foreign bodies. In Fundamental Aspects of Biocompatibility Williams DF. (ed). Boca Raton: CRC Press Inc; 1981: 139-58.
- 12 Mathiesen EB, Lindgren JU, Reinholt FP. et al. Tissue reactions to wear products from polyacetal (Delrin) and UHMW polyethylene in total hip replacement. J Biomed Mater Res 1987; (21) 459-66.