Thorac Cardiovasc Surg 2019; 67(01): 002-007
DOI: 10.1055/s-0037-1621706
Original Cardiovascular
Georg Thieme Verlag KG Stuttgart · New York

Reasons for Failure of Systemic-to-Pulmonary Artery Shunts in Neonates

Keti Vitanova
1   Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich, Germany
2   Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich Germany
,
Cornelius Leopold
1   Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich, Germany
2   Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich Germany
,
Jelena Pabst von Ohain
1   Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich, Germany
2   Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich Germany
,
Cordula Wolf
3   Department of Pediatric Cardiology and Congenital Heart Disease, German Heart Centre Munich, Technische Universität München, Germany
,
Elisabeth Beran
1   Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich, Germany
2   Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich Germany
,
Rüdiger Lange
1   Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich, Germany
2   Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich Germany
4   German Heart Center Munich - DZHK Partner Site Munich Heart Alliance, Munich, Germany
,
Julie Cleuziou
1   Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich, Germany
2   Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Centre Munich, Technische Universität München, Munich Germany
› Author Affiliations
Further Information

Address for correspondence

Keti Vitanova, MD
Department of Cardiovascular Surgery, German Heart Centre Munich
Lazarettstrasse 36, D-80636 Munich
Germany   

Publication History

03 November 2017

13 December 2017

Publication Date:
19 January 2018 (online)

 

Abstract

Background Systemic-to-pulmonary artery shunt placement is an established palliative procedure for congenital heart disease. Although it is thought to be a simple operation, it is associated with significant morbidity and mortality.

Methods Data for all neonates who underwent surgery for a systemic-to-pulmonary artery shunt between 2000 and 2016 were reviewed. The study endpoints were shunt failure and shunt-related mortality. Shunt failure was defined as a shunt dysfunction because of thrombosis or stenosis requiring intervention or reoperation; shunt mortality was defined as death because of a shunt dysfunction.

Results A total of 305 shunts (central shunt, n = 135; Blalock–Taussig shunt, n = 170) were implanted in 280 patients. The median patients' age at the time of surgery was 9 days (1–31 days). The median shunt size was 3.5 mm (3–4 mm). Twenty-four patients (8%) were diagnosed with a shunt failure, with a median time of 7 days (0–438 days). Freedom from shunt failure at 1 year was 91.6% ± 2%. A shunt-related mortality was ascertained for 12 patients (4%). Freedom from shunt-related mortality at 1 year was 96% ± 1%. Perioperative platelet transfusion (p = 0.01), central shunt (p = 0.02), 3-mm shunt size (p = 0.02), and postoperative extra corporeal membrane oxygenation (ECMO) (p < 0.01) were identified as risk factors for shunt failure. Platelet transfusion (p = 0.04) and postoperative ECMO (p < 0.01) were further identified as risk factors for shunt mortality.

Conclusion Based on these data, we recommend implanting a modified Blalock–Taussig shunt of at least 3.5 mm in neonates. Perioperative platelet transfusion and postoperative ECMO increase the risk of shunt failure.


#

Introduction

Systemic-to-pulmonary artery shunt surgery is a palliative procedure for congenital heart disease associated with diminished or absent pulmonary blood flow. Systemic-to-pulmonary artery shunts were first described by Blalock and Taussig in 1945 (subclavian-to-pulmonary artery shunt),[1] Potts in 1946 (descending aorta-to-left pulmonary artery [PA] shunt),[2] and Waterston and Cooley in 1962 and 1966 (ascending aorta-to-right PA shunt).[3] [4] In 1975, de Leval modified the technique, using a polytetrafluoroethylene (PTFE) interposition graft known as a modified Blalock–Taussig shunt (mBTS).[5]

Despite numerous improvements in diagnosis, intensive care medicine, and intraoperative management in recent decades, overall outcomes remain unsatisfactory with an mBTS. Mortality is considered relatively high with an average of 10%.[6] [7] [8] Complications including shunt stenosis or thrombosis are reported in 8% to 13%.[9] Several single institution studies or case series investigated risk factors for morbidity and mortality after mBTS and identified age, weight,[10] [11] [12] [13] and single ventricle circulation[9] [14] as risk factors for death.

However, outcomes of shunt surgery are often reported in generalizing terms, regardless of patients' ages. Therefore, we sought to study the neonatal population specifically to identify potential risk factors for adverse outcomes after lifesaving shunt surgery.


#

Materials and Methods

All neonates who underwent implantation of a systemic-to-pulmonary artery shunt between 2000 and 2016 at the German Heart Centre Munich were included in the study. Patients were identified from our clinical database, and medical records and operative notes were reviewed. All patients were examined regularly after surgery in our outpatient clinic or by the referring pediatric cardiologist.

We defined two study endpoints:

  • Shunt failure defined as shunt thrombosis or stenosis, and

  • Shunt-related mortality defined as a subsequent death after shunt failure.

After surgery, the patients were examined daily using echocardiography during their intensive care unit (ICU) stay and once before discharge. After hospital discharge, all patients were seen every 4 to 6 weeks in our outpatient clinic and were examined using echocardiography. Angiography was routinely planned for all patients 3 to 6 months after shunt implantation prior to further surgery. If there were any signs of reduced shunt flow on echocardiography, an angiography was performed at an earlier time. In patients with a remarkably reduced shunt flow or acute hypoxemia, an operative revision was performed immediately, without prior angiography.

Surgical Technique

For nearly all patients, surgery was performed using a median sternotomy on cardiopulmonary bypass. The brachiocephalic trunk and right PA were dissected free. A bolus of 100 IU/kg of heparin was administered if surgery was performed without bypass. The brachiocephalic trunk was clamped with a side-biting clamp, and a longitudinal arteriotomy was performed. An obliquely fashioned thin-walled Gore-Tex stretch vascular graft (W. L. Gore & Associates, Inc., Arizona, United States) was sutured end-to-side to the brachiocephalic trunk. The clamp was released, and good shunt flow was ascertained. After trimming the shunt to the right length, it was anastomosed to the right PA. If the aortic arch descended to the right, the shunt was anastomosed to the left PA. A central shunt was placed for anatomical reasons or at the discretion of the attending surgeon. The anatomy was considered unsuitable for mBTS if the PAs were hypoplastic. Central shunt placement was performed by interposing a thin-walled Gore-Tex stretch vascular graft between the ascending aorta and PA in a similar fashion using the pulmonary trunk or bifurcation in cases of hypoplastic peripheral PAs.

RV-PA (Sano) shunts used in patients with single ventricle circulation were excluded from the study.

Postoperative anticoagulation was performed according to the internal clinic standards as follows:

  • Shunts < 4 mm: intravenous heparin (5,000 IE/m2/d) beginning 6 hours after surgery until removal of the central venous catheter. Oral aspirin (3–5 mg/kg) was administered thereafter.

  • Shunts > 4 mm: intravenous heparin (5,000 IE/m2/d) beginning 6 hours after surgery until removal of the central venous catheter; no postoperative aspirin was administered.


#

Statistical Analysis

Statistical analysis was performed using SPSS 22.0 software (SPSS Inc., Chicago, Illinois, United States). Frequencies are presented as absolute numbers and percentages. Continuous data are presented as medians with ranges or means with standard deviation. A comparison of categorical variables was calculated using a two-tailed χ 2 test or Fisher exact test, as appropriate. A comparison of continuous variables was calculated using a t-test for independent samples. The Kaplan–Meier method was used to estimate the probability of freedom from events. The Cox regression analysis was used to identify the risk factors for events. For all tests, a p-value of ≤0.05 was considered significant.


#
#

Results

Patients

A total of 305 shunts were implanted in 280 patients. The median patient age at the time of surgery was 9 days (1–31 days). Sixty-one percent (n = 172) of the patients had single ventricle circulation. Preoperative patients' characteristics are summarized in [Table 1].

Table 1

Preoperative characteristics of 280 neonates

Total, n

280

Age (days)

9 (1–31)

Weight (kg)

3.8 [1.8–4.6]

Male, n (%)

173 (62)

Diagnosis, n (%)

HLHS

144 (51)

TGA, VSD, LVOTO/ccTGA, PS

42 (15)

PA, VSD ± MAPCA

37 (13)

TOF

36 (13)

PA IVS

21 (8)

Type circulation, n (%)

Single ventricle

172 (61)

Biventricular

108 (39)

Abbreviations: ccTGA, congenitally corrected transposition of the great arteries; HLHS, hypoplastic left heart syndrome; LVOTO, left ventricular outflow tract obstruction; MAPCA, multiple aortopulmonary collateral arteries; PA, pulmonary atresia; PA IVS, pulmonary atresia with intact ventricular septum; PS, pulmonary stenosis; TGA, transposition of the great arteries; TOF, tetralogy of Fallot; VSD, ventricular septal defect.


The shunts were implanted with an mBTS in 170 cases (56%) and a central shunt in 135 cases (44%). All mBTS were positioned between the brachiocephalic trunk and right PA. There were no left mBTS implanted. The shunt sizes were 3, 3.5, and 4 mm, respectively. Heparin-coated shunts were used in almost one-half of the patients (48%, n = 148). The indexed shunt size (mm/kg) was 1.2 ± 0.2. The indexed shunt size was >1 for 225 patients and ≥1.5 for 20 patients. All shunt characteristics are summarized in [Table 2].

Table 2

Characteristics of 305 implanted shunts

Total, n (%)

305

mBTS with ECC

161 (53)

mBTS without ECC

9 (3)

Central shunt with ECC

124 (41)

Central shunt without ECC

11 (3)

ECC

285 (94)

3 mm

42 (14)

3.5 mm

108 (35)

4 mm

155 (51)

Heparin coated

148 (48)

Indexed shunt size, mm/kg

1.2 ± 0.2

Abbreviation: ECC, extracorporeal circulation; mBTS, modified Blalock–Taussig shunt


A competitive antegrade flow was present after shunt placement in 16 patients (16/280, 6%) who had pulmonary atresia, a ventricular septal defect, and major aortopulmonary collateral arteries (PA, ventricular septal defect [VSD], and multiple aortopulmonary collateral arteries [MAPCAs]).

Postoperative extra corporeal membrane oxygenation (ECMO) was urgently required for 17 patients (5.5%) in the ICU during the postoperative period and was implanted under cardiopulmonary resuscitation (CPR). Reasons for ECMO were an acute cardiac failure for 13 patients and acute hypoxemia for four patients. At the time of the ECMO implantation, the shunt was partially clipped in six patients to ensure adequate circulatory blood flow on ECMO.

One-third of the patients with thrombocytopenia (34%, n = 104) required a platelet transfusion. All patients on ECMO needed platelet substitution. Seven patients had to undergo a reoperation for postoperative bleeding. Five of them were on ECMO.

A total of 243 angiographies were performed after surgery; 231 were regularly scheduled prior to an additional operation, and 12 were scheduled earlier if on echocardiography was detected a reduced or not clear shunt flow. Another 12 patients underwent surgery on an emergency basis without prior angiography after a remarkably reduced shunt flow had been detected on echocardiography.


#

Mortality

Thirty-day mortality was 11% (n = 35). A shunt-related mortality was confirmed for 12 patients (4%, shunt stenosis n = 4; shunt thrombosis n = 8). The other 23 patients (23/35) died because of myocardial failure (n = 19) or septicemia (n = 4). For all 23 patients, an autopsy confirmed a patent shunt. After discharge from the hospital, nine patients died, all of whom experienced acute cardiac failure. Two-thirds (n = 234, 78%) of the patients underwent corrective surgery or obtained further palliation. The course for all implanted shunts is depicted in [Fig. 1].

Zoom Image
Fig. 1 Course of 305 shunts in 280 neonates.

#

Shunt Failure and Shunt-Related Mortality

A total of 24 patients (8%) had a shunt failure at a median of 7 days (0–438 days). Angiography revealed a shunt stenosis in six patients. They were treated with balloon angioplasty (n = 2), stent implantation (n = 1), or shunt exchange (n = 3). After intervention (balloon angioplasty and stent implantation), all patients required reoperation for shunt exchange after a mean time of 6 ± 2 days.

A shunt thrombosis was diagnosed in six patients using angiography. They all required a reoperation for shunt exchange. Additionally, upon autopsy, four patients had a shunt thrombosis. All four patients died after unsuccessful CPR.

Shunt-related mortality was 4% (n = 12) at a median of 9 days (0–433 days). Eight patients died after unsuccessful CPR because of sudden hypoxemia with subsequent bradycardia and acute myocardial failure. Four patients died from shunt thrombosis. The course for the patients who had a shunt failure is depicted in [Fig. 2]. The freedom from shunt failure was 91.6% ± 2% at 1 year ([Fig. 3]). The freedom from shunt-related mortality was 96% ± 1% at 1 year ([Fig. 4]).

Zoom Image
Fig. 2 Course of 24 patients with shunt failure.
Zoom Image
Fig. 3 Freedom from shunt failure.
Zoom Image
Fig. 4 Freedom from shunt-related mortality.

#

Risk Factors for Shunt Failure and Shunt-Related Mortality

A perioperative platelet transfusion, central shunt placement, and shunt size of 3 mm, as well as the use of postoperative ECMO, were identified as risk factors for shunt failure. A platelet transfusion and postoperative ECMO were also risk factors for shunt-related mortality ([Table 3]).

Table 3

Risk factors for shunt failure and shunt-related mortality

Variable

Univariate analysis

Multivariate analysis

Shunt failure

HR

95% CI

p

HR

95% CI

p

Postoperative ECMO

5.9

2.4–14.5

<0.01

5.8

2–17.1

0.001

Central shunt

2.6

1.1–6.1

0.02

Shunt size of 3 mm

2.7

1.1–6.5

0.02

Transfusion of platelets

2.7

1.2–6

0.01

Shunt-related mortality

Postoperative ECMO

20

5.8–71

<0.01

4.5

1.2–15.9

0.02

Transfusion of platelets

3.2

1–10.4

0.04


#
#

Discussion

Systemic-to-pulmonary artery shunt surgery is an effective palliative procedure for cyanotic congenital heart disease. Although it is thought to be technically easy to perform, shunt surgery is still associated with a poor postoperative outcome. Our study reports on 15 years' experience involving a large single center cohort including 305 shunt procedures in neonates. We found that early postoperative mortality was not always related to shunt pathology. Only 4% (n = 12) died because of shunt-related reasons. A total of 24 patients (8%) developed a shunt failure that was affected by the type and size of the shunt. The implementation of postoperative ECMO and a platelet transfusion increased the risk of shunt failure and shunt-related mortality.

Several single center reports evaluated the outcomes of shunt surgery, but the majority was published in an earlier era. These studies reported mortality ranging from 3.7% to 14%.[6] [13] [15] [16] [17] Among these, Gold et al reported the lowest mortality rate, but the patients in their series had a mean age of 3 months.[15] Lamberti et al had a mortality rate of 2.3%, with 1 death of a 1.7-kg neonate who had pulmonary atresia. This series consisted of patients with a mean age of 6 months.[13] Williams et al reported on the largest series of mBTS. They analyzed 2,000 patients over a period of six decades in a multicenter study with an overall mortality of 14%. However, patients who were older than a neonatal age were included in this report.[18] More recent publications analyzed the outcomes after shunt surgery and reported on only neonates.[9] [14] [17] Petrucci et al included 1,273 patients using the multi-institutional STS Congenital Database. Remarkably, their data demonstrated that mBTS continues to be a high-risk procedure, with an overall mortality of 7.2%.[14] In 2014, Bove et al reported on 150 neonates who had an overall hospital mortality of 8.7% after shunt surgery.[9] In our study, the 30-day mortality after shunt surgery was 11% (n = 35), but shunt-related mortality was only 4%.

There is a lack of publications analyzing the reasons for shunt-related mortality. The autopsy results in our study showed that acute heart failure or septicemia was the predominant cause of death in 23 of the 35 patients who died with a shunt in situ. In these patients, no pathology was found on the shunt. We identified two risk factors for shunt-related mortality in neonates that have not been previously reported: a platelet transfusion and the implementation of postoperative ECMO. A relationship between both factors is evident, as all patients on ECMO (n = 17, 5.5%) in our study underwent a postoperative platelet transfusion. Patients on ECMO have an increased risk of postoperative bleeding because of heparinization and platelet consumption and may require the replacement of platelets. However, not just patients on ECMO needed a platelet transfusion. One-third of our patients (34%, n = 104) underwent a postoperative platelet transfusion to stabilize their postoperative thrombocytopenia. Transfusion of other blood products such as fresh frozen plasma or packed red blood cells had no influence on shunt-related mortality. Another point concerning postoperative ECMO as a risk factor for mortality is the altered blood flow caused by ECMO. Therefore, in six patients, shunt clipping was performed to ensure adequate circulatory blood flow on ECMO to prevent a pulmonary steal effect. We think that shunt clipping could ensure adequate circulatory blood flow on ECMO, but the clipping could lead to shunt thrombosis, a condition more fatal for a neonate. Four out of 17 patients who required ECMO developed a shunt failure. Two of these patients did not survive this condition. These two patients required initially shunt clipping, which underwent with complication; both became shunt thrombosis. Therefore, the shunt was changed. Postoperatively, both patients developed multiple organ failure on ECMO and the ECMO could not be weaned successfully.

A multivariate risk factor analysis for mortality in an older report from 1995 identified that a left mBTS and male sex were associated with increased mortality.[6] Other authors determined that pulmonary atresia with an intact ventricular septum, weight of <3 kg,[14] weight of <2 kg,[17] and univentricular circulation[9] [14] were significant risk factors for mortality after shunt surgery. In our study, low weight, sex, and single ventricle physiology had no influence on postoperative mortality. Considering that the prevalent cause of death in our cohort was acute heart failure (n = 19), we assumed that the underlying diagnosis had a major influence on the outcome. However, we could not identify a correlation between the nature of a patient's heart defect and mortality after shunt placement.

Bove et al reported that excessive pulmonary blood flow through shunts could contribute to mortality.[9] Dirks et al found that there was a trend toward increased mortality in patients in whom a shunt had to be decreased in size to reduce excessive blood flow.[8] In contrast, in the present study, we did not find that an oversized shunt increased the risk of mortality. Sixteen patients in our study had additional antegrade flow through MAPCAs, and 20 had an indexed shunt size of ≥1.5. However, neither the extra blood flow nor a larger indexed shunt size could be identified as a risk factor.

Another concern after shunt surgery is shunt failure because of thrombosis or a stenosis. We found that a perioperative platelet transfusion increased the risk of shunt failure. ECMO implantation was proven to have an adverse outcome after shunt surgery in our study. ECMO implantation was identified as the unique independent risk factor for shunt failure in the multivariate analysis. ECMO implantation increases the risk of bleeding, as well as the risk of coagulopathy and thrombosis regardless of the type of surgery.[19]

It is well known that a younger age and smaller-sized shunt are significantly related to shunt thrombosis.[20] [21] Other reports have also linked patients' weight to shunt thrombosis.[14] [22] It is conceivable that a low weight is directly related to the size of the vessels, leading to the more frequent use of smaller shunts in neonates. Weight had no influence on shunt failure in our cohort. However, a shunt size of 3 mm increased the risk of shunt failure. In addition, a central shunt was identified as a risk factor for shunt failure. Central shunts were implanted in patients with hypoplastic pulmonary arteries in whom the postshunt runoff may be compromised.[23]

We could not find an association between anticoagulation regimens and shunt failure. All our patients were on continuous intravenous heparin after shunt surgery. In addition, patients with a shunt size of less than 4 mm were administered aspirin postoperatively. Further, a smaller shunt size remained a risk factor for shunt failure. The early postoperative period with fresh surgical anastomoses, coupled with periods of low systemic pressures, pulmonary hypertension, and consecutive blood stasis, may initiate thrombus formation.[8] Li et al demonstrated a reduced incidence of shunt thrombosis (p = 0.008) and death (p = 0.057) in patients administered aspirin, as compared with those not administered aspirin.[24] Another prospective study showed significantly higher shunt patency rates with hemodilution while maintaining a hematocrit of 45%.[25]

Heparin-coated PTFE shunts have been available since 2011, and 48% of the shunts in our cohort were heparin coated. Their potential advantage of reducing acute shunt occlusion by lowering thrombus formation and accelerating endothelialization could not be proven in our study. In a previous histopathological workup of PTFE shunts, partial endothelialization and discrete pseudointima proliferation were shown to be equal in both heparin-coated and nonheparin-coated shunts.[26]


#

Conclusion

In neonates, implantation of an mBTS of at least 3.5 mm may be recommended, as opposed to a central shunt. Platelet transfusion should be avoided after shunt surgery. Postoperative ECMO has a poor prognosis regarding morbidity and mortality after shunt surgery.


#
#

No conflict of interest has been declared by the author(s).

Acknowledgment

This study was supported by the Werner Reichenberger Foundation for Child Health.

Note

Presented at 46th Annual Meeting of DGTHG, 11.-14.02.2017 in Leipzig, Germany


  • References

  • 1 Blalock A, Taussig HB. Landmark article May 19, 1945: The surgical treatment of malformations of the heart in which there is pulmonary stenosis or pulmonary atresia. JAMA 1984; 251 (16) 2123-2138
  • 2 Potts WJ, Smith S, Gibson S. Anastomosis of the aorta to a pulmonary artery; certain types in congenital heart disease. J Am Med Assoc 1946; 132 (11) 627-631
  • 3 Waterston DJ. [Treatment of Fallot's tetralogy in children under 1 year of age]. Rozhl Chir 1962; 41: 181-183
  • 4 Cooley DA, Hallman GL. Intrapericardial aortic-right pulmonary arterial anastomosis. Surg Gynecol Obstet 1966; 122 (05) 1084-1086
  • 5 de Leval MR, McKay R, Jones M, Stark J, Macartney FJ. Modified Blalock-Taussig shunt. Use of subclavian artery orifice as flow regulator in prosthetic systemic-pulmonary artery shunts. J Thorac Cardiovasc Surg 1981; 81 (01) 112-119
  • 6 Odim J, Portzky M, Zurakowski D. , et al. Sternotomy approach for the modified Blalock-Taussig shunt. Circulation 1995; 92 (9, Suppl): II256-II261
  • 7 McKenzie ED, Khan MS, Samayoa AX. , et al. The Blalock-Taussig shunt revisited: a contemporary experience. J Am Coll Surg 2013; 216 (04) 699-704 , discussion 704–706
  • 8 Dirks V, Prêtre R, Knirsch W. , et al. Modified Blalock Taussig shunt: a not-so-simple palliative procedure. Eur J Cardiothorac Surg 2013; 44 (06) 1096-1102
  • 9 Bove T, Vandekerckhove K, Panzer J, De Groote K, De Wolf D, François K. Disease-specific outcome analysis of palliation with the modified Blalock-Taussig shunt. World J Pediatr Congenit Heart Surg 2015; 6 (01) 67-74
  • 10 Kyger III ER, Reul Jr GJ, Sandiford FM, Wukasch DC, Hallman GL, Cooley DA. Surgical palliation of tricuspid atresia. Circulation 1975; 52 (04) 685-690
  • 11 Donahoo JS, Gardner TJ, Zahka K, Kidd BS. Systemic-pulmonary shunts in neonates and infants using microporous expanded polytetrafluoroethylene: immediate and late results. Ann Thorac Surg 1980; 30 (02) 146-150
  • 12 Guyton RA, Owens JE, Waumett JD, Dooley KJ, Hatcher Jr CR, Williams WH. The Blalock-Taussig shunt. Low risk, effective palliation, and pulmonary artery growth. J Thorac Cardiovasc Surg 1983; 85 (06) 917-922
  • 13 Lamberti JJ, Carlisle J, Waldman JD. , et al. Systemic-pulmonary shunts in infants and children. Early and late results. J Thorac Cardiovasc Surg 1984; 88 (01) 76-81
  • 14 Petrucci O, O'Brien SM, Jacobs ML, Jacobs JP, Manning PB, Eghtesady P. Risk factors for mortality and morbidity after the neonatal Blalock-Taussig shunt procedure. Ann Thorac Surg 2011; 92 (02) 642-651 , discussion 651–652
  • 15 Gold JP, Violaris K, Engle MA. , et al. A five-year clinical experience with 112 Blalock-Taussig shunts. J Card Surg 1993; 8 (01) 9-17
  • 16 Gladman G, McCrindle BW, Williams WG, Freedom RM, Benson LN. The modified Blalock-Taussig shunt: clinical impact and morbidity in Fallot's tetralogy in the current era. J Thorac Cardiovasc Surg 1997; 114 (01) 25-30
  • 17 Alkhulaifi AM, Lacour-Gayet F, Serraf A, Belli E, Planché C. Systemic pulmonary shunts in neonates: early clinical outcome and choice of surgical approach. Ann Thorac Surg 2000; 69 (05) 1499-1504
  • 18 Williams JA, Bansal AK, Kim BJ. , et al. Two thousand Blalock-Taussig shunts: a six-decade experience. Ann Thorac Surg 2007; 84 (06) 2070-2075 , discussion 2070–2075
  • 19 Makdisi G, Wang IW. Extra corporeal membrane oxygenation (ECMO) review of a lifesaving technology. J Thorac Dis 2015; 7 (07) E166-E176
  • 20 Tsai KT, Chang CH, Lin PJ. Modified Blalock-Taussig shunt: statistical analysis of potential factors influencing shunt outcome. J Cardiovasc Surg (Torino) 1996; 37 (02) 149-152
  • 21 Tamisier D, Vouhé PR, Vernant F, Lecá F, Massot C, Neveux JY. Modified Blalock-Taussig shunts: results in infants less than 3 months of age. Ann Thorac Surg 1990; 49 (05) 797-801
  • 22 Gedicke M, Morgan G, Parry A, Martin R, Tulloh R. Risk factors for acute shunt blockage in children after modified Blalock-Taussig shunt operations. Heart Vessels 2010; 25 (05) 405-409
  • 23 Ishikawa S, Takahashi T, Sato Y. , et al. Growth of the pulmonary arteries after systemic-pulmonary shunt. Ann Thorac Cardiovasc Surg 2001; 7 (06) 337-340
  • 24 Li JS, Yow E, Berezny KY. , et al. Clinical outcomes of palliative surgery including a systemic-to-pulmonary artery shunt in infants with cyanotic congenital heart disease: does aspirin make a difference?. Circulation 2007; 116 (03) 293-297
  • 25 Sahoo TK, Chauhan S, Sahu M, Bisoi A, Kiran U. Effects of hemodilution on outcome after modified Blalock-Taussig shunt operation in children with cyanotic congenital heart disease. J Cardiothorac Vasc Anesth 2007; 21 (02) 179-183
  • 26 Hörer J, Cleuziou J, Kasnar-Samprec J. , et al. A comparative histopathological study of heparin coated and uncoated polytetrafluoroethylene shunts in children with congenital heart defect. World J Pediatr Congenit Heart Surg 2014; 5 (03) 385-390

Address for correspondence

Keti Vitanova, MD
Department of Cardiovascular Surgery, German Heart Centre Munich
Lazarettstrasse 36, D-80636 Munich
Germany   

  • References

  • 1 Blalock A, Taussig HB. Landmark article May 19, 1945: The surgical treatment of malformations of the heart in which there is pulmonary stenosis or pulmonary atresia. JAMA 1984; 251 (16) 2123-2138
  • 2 Potts WJ, Smith S, Gibson S. Anastomosis of the aorta to a pulmonary artery; certain types in congenital heart disease. J Am Med Assoc 1946; 132 (11) 627-631
  • 3 Waterston DJ. [Treatment of Fallot's tetralogy in children under 1 year of age]. Rozhl Chir 1962; 41: 181-183
  • 4 Cooley DA, Hallman GL. Intrapericardial aortic-right pulmonary arterial anastomosis. Surg Gynecol Obstet 1966; 122 (05) 1084-1086
  • 5 de Leval MR, McKay R, Jones M, Stark J, Macartney FJ. Modified Blalock-Taussig shunt. Use of subclavian artery orifice as flow regulator in prosthetic systemic-pulmonary artery shunts. J Thorac Cardiovasc Surg 1981; 81 (01) 112-119
  • 6 Odim J, Portzky M, Zurakowski D. , et al. Sternotomy approach for the modified Blalock-Taussig shunt. Circulation 1995; 92 (9, Suppl): II256-II261
  • 7 McKenzie ED, Khan MS, Samayoa AX. , et al. The Blalock-Taussig shunt revisited: a contemporary experience. J Am Coll Surg 2013; 216 (04) 699-704 , discussion 704–706
  • 8 Dirks V, Prêtre R, Knirsch W. , et al. Modified Blalock Taussig shunt: a not-so-simple palliative procedure. Eur J Cardiothorac Surg 2013; 44 (06) 1096-1102
  • 9 Bove T, Vandekerckhove K, Panzer J, De Groote K, De Wolf D, François K. Disease-specific outcome analysis of palliation with the modified Blalock-Taussig shunt. World J Pediatr Congenit Heart Surg 2015; 6 (01) 67-74
  • 10 Kyger III ER, Reul Jr GJ, Sandiford FM, Wukasch DC, Hallman GL, Cooley DA. Surgical palliation of tricuspid atresia. Circulation 1975; 52 (04) 685-690
  • 11 Donahoo JS, Gardner TJ, Zahka K, Kidd BS. Systemic-pulmonary shunts in neonates and infants using microporous expanded polytetrafluoroethylene: immediate and late results. Ann Thorac Surg 1980; 30 (02) 146-150
  • 12 Guyton RA, Owens JE, Waumett JD, Dooley KJ, Hatcher Jr CR, Williams WH. The Blalock-Taussig shunt. Low risk, effective palliation, and pulmonary artery growth. J Thorac Cardiovasc Surg 1983; 85 (06) 917-922
  • 13 Lamberti JJ, Carlisle J, Waldman JD. , et al. Systemic-pulmonary shunts in infants and children. Early and late results. J Thorac Cardiovasc Surg 1984; 88 (01) 76-81
  • 14 Petrucci O, O'Brien SM, Jacobs ML, Jacobs JP, Manning PB, Eghtesady P. Risk factors for mortality and morbidity after the neonatal Blalock-Taussig shunt procedure. Ann Thorac Surg 2011; 92 (02) 642-651 , discussion 651–652
  • 15 Gold JP, Violaris K, Engle MA. , et al. A five-year clinical experience with 112 Blalock-Taussig shunts. J Card Surg 1993; 8 (01) 9-17
  • 16 Gladman G, McCrindle BW, Williams WG, Freedom RM, Benson LN. The modified Blalock-Taussig shunt: clinical impact and morbidity in Fallot's tetralogy in the current era. J Thorac Cardiovasc Surg 1997; 114 (01) 25-30
  • 17 Alkhulaifi AM, Lacour-Gayet F, Serraf A, Belli E, Planché C. Systemic pulmonary shunts in neonates: early clinical outcome and choice of surgical approach. Ann Thorac Surg 2000; 69 (05) 1499-1504
  • 18 Williams JA, Bansal AK, Kim BJ. , et al. Two thousand Blalock-Taussig shunts: a six-decade experience. Ann Thorac Surg 2007; 84 (06) 2070-2075 , discussion 2070–2075
  • 19 Makdisi G, Wang IW. Extra corporeal membrane oxygenation (ECMO) review of a lifesaving technology. J Thorac Dis 2015; 7 (07) E166-E176
  • 20 Tsai KT, Chang CH, Lin PJ. Modified Blalock-Taussig shunt: statistical analysis of potential factors influencing shunt outcome. J Cardiovasc Surg (Torino) 1996; 37 (02) 149-152
  • 21 Tamisier D, Vouhé PR, Vernant F, Lecá F, Massot C, Neveux JY. Modified Blalock-Taussig shunts: results in infants less than 3 months of age. Ann Thorac Surg 1990; 49 (05) 797-801
  • 22 Gedicke M, Morgan G, Parry A, Martin R, Tulloh R. Risk factors for acute shunt blockage in children after modified Blalock-Taussig shunt operations. Heart Vessels 2010; 25 (05) 405-409
  • 23 Ishikawa S, Takahashi T, Sato Y. , et al. Growth of the pulmonary arteries after systemic-pulmonary shunt. Ann Thorac Cardiovasc Surg 2001; 7 (06) 337-340
  • 24 Li JS, Yow E, Berezny KY. , et al. Clinical outcomes of palliative surgery including a systemic-to-pulmonary artery shunt in infants with cyanotic congenital heart disease: does aspirin make a difference?. Circulation 2007; 116 (03) 293-297
  • 25 Sahoo TK, Chauhan S, Sahu M, Bisoi A, Kiran U. Effects of hemodilution on outcome after modified Blalock-Taussig shunt operation in children with cyanotic congenital heart disease. J Cardiothorac Vasc Anesth 2007; 21 (02) 179-183
  • 26 Hörer J, Cleuziou J, Kasnar-Samprec J. , et al. A comparative histopathological study of heparin coated and uncoated polytetrafluoroethylene shunts in children with congenital heart defect. World J Pediatr Congenit Heart Surg 2014; 5 (03) 385-390

Zoom Image
Fig. 1 Course of 305 shunts in 280 neonates.
Zoom Image
Fig. 2 Course of 24 patients with shunt failure.
Zoom Image
Fig. 3 Freedom from shunt failure.
Zoom Image
Fig. 4 Freedom from shunt-related mortality.