J Knee Surg 2018; 31(05): 453-458
DOI: 10.1055/s-0037-1604145
Original Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Postoperative Stiffening after Bicruciate-Retaining Total Knee Arthroplasty

Frédéric Lavoie
1   Department of Surgery, Centre Hospitalier de l'Université de Montréal, Montréal, Quebec, Canada
,
Fidaa Al-Shakfa
1   Department of Surgery, Centre Hospitalier de l'Université de Montréal, Montréal, Quebec, Canada
,
James Reuben Moore
1   Department of Surgery, Centre Hospitalier de l'Université de Montréal, Montréal, Quebec, Canada
,
Lydia Mychaltchouk
1   Department of Surgery, Centre Hospitalier de l'Université de Montréal, Montréal, Quebec, Canada
,
Khaled Iguer
1   Department of Surgery, Centre Hospitalier de l'Université de Montréal, Montréal, Quebec, Canada
› Author Affiliations
Further Information

Publication History

15 December 2016

31 May 2017

Publication Date:
24 July 2017 (online)

Abstract

Bicruciate-retaining (BCR) total knee arthroplasty (TKA) has recently experienced a resurgence of popularity. It may be a good option among a younger, more active population because it restores knee kinematics better than other prosthetic designs. Results obtained in the first 100 BCR TKAs implanted with a simplified gap-balancing technique are reported, with special attention paid to knee flexion, through comparison with a cohort of 100 posterior-stabilized (PS) TKAs. We conducted a retrospective comparative cohort study of 100 BCR TKAs (90 patients) and 100 PS TKAs (88 patients). Knees with a BCR TKA lost significantly more flexion PS TKA in the early postoperative period when their preoperative flexion was less than 130 degrees (loss of 40 degrees vs. loss of 24 degrees). Postoperative range of motion was similar between BCR TKA and PS TKA when preoperative knee flexion was 130 degrees or more, and when there was no preoperative flexion contracture. Postoperative stiffening seems to be more frequent and of greater magnitude after BCR TKA, compared with PS TKA, in patients suffering from preoperative flexion stiffness. Further investigation on the causes of this phenomenon is warranted.

 
  • References

  • 1 Andriacchi TP, Galante JO, Fermier RW. The influence of total knee-replacement design on walking and stair-climbing. J Bone Joint Surg Am 1982; 64 (09) 1328-1335
  • 2 Komistek RD, Allain J, Anderson DT, Dennis DA, Goutallier D. In vivo kinematics for subjects with and without an anterior cruciate ligament. Clin Orthop Relat Res 2002; (404) 315-325
  • 3 Migaud H, Gougeon F, Diop A, Lavaste F, Duquennoy A. Cinematic in vivo analysis of the knee: a comparative study of 4 types of total knee prostheses [in French]. Rev Chir Orthop Repar Appar Mot 1995; 81 (03) 198-210
  • 4 Stiehl JB, Komistek RD, Cloutier JM, Dennis DA. The cruciate ligaments in total knee arthroplasty: a kinematic analysis of 2 total knee arthroplasties. J Arthroplasty 2000; 15 (05) 545-550
  • 5 Halewood C, Traynor A, Bellemans J, Victor J, Amis AA. Anteroposterior laxity after bicruciate-retaining total knee arthroplasty is closer to the native knee than ACL-resecting TKA: A biomechanical cadaver study.. J Arthroplasty 2015; 30 (12) 2315-2319
  • 6 Ward TR, Burns AW, Gillespie MJ, Scarvell JM, Smith PN. Bicruciate-stabilised total knee replacements produce more normal sagittal plane kinematics than posterior-stabilised designs. J Bone Joint Surg Br 2011; 93 (07) 907-913
  • 7 Bellemans J, Corten K, Vanlauwe J. , et al. Bicruciate retaining TKA: the future? In: Bonnin M, Amendola NA, Bellemans J, MacDonald SJ, Menetrey J. , eds. The Knee Joint: Surgical Techniques and Strategies. New York, NY: Springer Healthcare LLC; 2012: 735-739
  • 8 Cloutier JM. Results of total knee arthroplasty with a non-constrained prosthesis. J Bone Joint Surg Am 1983; 65 (07) 906-919
  • 9 Robinson RP. The early innovators of today's resurfacing condylar knees. J Arthroplasty 2005; 20 (01) (Suppl. 01) 2-26
  • 10 Townley CO. The anatomic total knee resurfacing arthroplasty. Clin Orthop Relat Res 1985; (192) 82-96
  • 11 Pritchett JW. Anterior cruciate-retaining total knee arthroplasty. J Arthroplasty 1996; 11 (02) 194-197
  • 12 Pritchett JW. Patients prefer a bicruciate-retaining or the medial pivot total knee prosthesis. J Arthroplasty 2011; 26 (02) 224-228
  • 13 Sabouret P, Lavoie F, Cloutier JM. Total knee replacement with retention of both cruciate ligaments: a 22-year follow-up study. Bone Joint J 2013; 95-B (07) 917-922
  • 14 Buechel FF, Pappas MJ. Long-term survivorship analysis of cruciate-sparing versus cruciate-sacrificing knee prostheses using meniscal bearings. Clin Orthop Relat Res 1990; (260) 162-169
  • 15 Hamelynck KJ, Stiehl JB, Voorhorst PE. LCS Multicenter Worldwide Outcome Study. In: Hamelynck KJ, Stiehl JB. , eds. LCS Mobile Bearing Knee Arthroplasty: A 25 Years Worldwide Review. New York, NY: Springer Healthcare LLC; 2002: 212-224
  • 16 Pritchett JW. Bicruciate-retaining total knee replacement provides satisfactory function and implant survivorship at 23 years. Clin Orthop Relat Res 2015; 473 (07) 2327-2333
  • 17 Keblish PA. The lateral approach for total knee arthroplasty. J Knee Surg 2003; 16 (01) 62-68
  • 18 Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 1989; (248) 13-14
  • 19 Goutallier D, Manicom O, Van Driessche S. Total knee arthroplasty with bicruciate preservation: Comparison versus the same posterostabilized design at eight years follow-up [in French]. Rev Chir Orthop Repar Appar Mot 2008; 94 (06) 585-595
  • 20 Anouchi YS, McShane M, Kelly Jr F, Elting J, Stiehl J. Range of motion in total knee replacement. Clin Orthop Relat Res 1996; (331) 87-92
  • 21 Gadinsky NE, Ehrhardt JK, Urband C, Westrich GH. Effect of body mass index on range of motion and manipulation after total knee arthroplasty. J Arthroplasty 2011; 26 (08) 1194-1197
  • 22 Kawamura H, Bourne RB. Factors affecting range of flexion after total knee arthroplasty. J Orthop Sci 2001; 6 (03) 248-252
  • 23 Li PH, Wong YC, Wai YL. Knee flexion after total knee arthroplasty. J Orthop Surg (Hong Kong) 2007; 15 (02) 149-153
  • 24 Harvey IA, Barry K, Kirby SP, Johnson R, Elloy MA. Factors affecting the range of movement of total knee arthroplasty. J Bone Joint Surg Br 1993; 75 (06) 950-955
  • 25 Lizaur A, Marco L, Cebrian R. Preoperative factors influencing the range of movement after total knee arthroplasty for severe osteoarthritis. J Bone Joint Surg Br 1997; 79 (04) 626-629
  • 26 Sancheti KH, Sancheti PK, Shyam AK, Joshi R, Patil K, Jain A. Factors affecting range of motion in total knee arthroplasty using high flexion prosthesis: A prospective study. Indian J Orthop 2013; 47 (01) 50-56
  • 27 Abolghasemian M, Samiezadeh S, Sternheim A, Bougherara H, Barnes CL, Backstein DJ. Effect of patellar thickness on knee flexion in total knee arthroplasty: a biomechanical and experimental study. J Arthroplasty 2014; 29 (01) 80-84