J Neurol Surg Rep 2016; 77(03): e134-e138
DOI: 10.1055/s-0035-1568134
Case Report
Georg Thieme Verlag KG Stuttgart · New York

Delayed Presentation of Sciatic Nerve Injury after Total Hip Arthroplasty: Neurosurgical Considerations, Diagnosis, and Management

Linda W. Xu
1   Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, United States
,
Anand Veeravagu
1   Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, United States
,
Tej D. Azad
1   Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, United States
,
Ciara Harraher
1   Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, United States
,
John K. Ratliff
1   Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, United States
› Author Affiliations
Further Information

Address for correspondence

Anand Veeravagu, MD
Department of Neurosurgery, Stanford University School of Medicine
300 Pasteur Drive, Stanford, CA 94305
United States   

Publication History

23 December 2015

11 October 2015

Publication Date:
05 September 2016 (online)

 

Abstract

Background Total hip arthroplasty (THA) is an established treatment for end-stage arthritis, congenital deformity, and trauma with good long-term clinical and functional outcomes. Delayed sciatic nerve injury is a rare complication after THA that requires prompt diagnosis and management.

Methods We present a case of sciatic nerve motor and sensory deficit in a 52-year-old patient 2 years after index left THA. Electromyography (EMG) results and imaging with radiographs and CT of the affected hip demonstrated an aberrant acetabular cup screw in the posterior-inferior quadrant adjacent to the sciatic nerve.

Case Description The patient underwent surgical exploration that revealed injury to the peroneal division of the sciatic nerve due to direct injury from screw impingement. A literature review identified 11 patients with late-onset neuropathy after THA. Ten patients underwent surgical exploration and pain often resolved after surgery with 56% of patients recovering sensory function and 25% experiencing full recovery of motor function.

Conclusions Delayed neuropathy of the sciatic nerve is a rare complication after THA that is most often due to hardware irritation, component failure, or wear-related pseudotumor formation. Operative intervention is often pursued to explore and directly visualize the nerve with limited results in the literature showing modest relief of pain and sensory symptoms and poor restoration of motor function.


#

Introduction

Approximately 225,000 primary total hip arthroplasties (THAs) are performed in the United States per year, and projections indicate that more than 4 million THAs will be performed annually by 2030.[1] Neurologic injury after THA is reported to occur in 0.09 to 3.7% of primary THAs and 0 to 7.4% of revision THAs.[2] Noted causes of neurologic injury include direct intraoperative nerve injury, leg lengthening, excess retraction, cement extravasation, cement-related thermal damage, patient positioning, and postoperative hematoma.[2] The majority of these injuries are symptomatic within the early postoperative period and can be managed conservatively with close follow-up. Delayed onset of neurologic injury is a rare complication with a unique differential diagnosis requiring appropriate management.

We report a case of neuropathy caused by malposition of an acetabular cup screw causing direct injury to the sciatic nerve. The patient developed progressively worsening loss of ankle dorsiflexion, resulting in complete footdrop 2 years after initial THA. The presentation, intervention, and outcome of other cases of delayed neuropathy are reviewed in the present report. Delayed neuropathies are most often caused by irritation from hardware, component failure, or wear-related pseudotumors.


#

Case Report

Initial Operative Intervention

The patient was a 52-year-old woman with end-stage arthritis of her bilateral hips with previous uncomplicated right THA that underwent an elective left THA. No intraoperative complications, abnormal anatomic landmarks, or events were noted at the time of surgery. Fluoroscopy confirmed equal limb lengths and appropriate hardware placement.


#

Re-presentation and Examination

The patient's initial orthopedic postoperative course was complicated by paresthesias of the right lower extremity, severe hypesthetic pain primarily in the lateral and anterior aspect of the right calf, and severe sciatica. During her hospital stay, the patient's sensation and pain improved; however, less than 1 year after her THA she noted gradual onset of weakness in her right lower extremity.

Two years after THA she presented to our neurosurgical clinic. At that time, she had developed a complete footdrop with loss of ankle dorsiflexion and required the use of an ankle-foot orthosis (AFO) to ambulate. She underwent an EMG at an outside facility, had a neurologic evaluation, and was undergoing physical therapy. Her only significant medical history was hypertension.

On physical examination, the patient had 0/5 dorsiflexion strength with 3/5 eversion and 5/5 inversion and plantarflexion strength. She had no Tinel sign over the fibular head. Decreased sensation was noted in the lateral aspect of the leg and the dorsum of the foot. She had no gross deformity of the lower extremity and had normal quadriceps and hamstring strength at the knee and the hip.

EMG showed severely reduced amplitude of the peroneal compound muscle action potentials and unrecordable superficial peroneal sensory response. There was also mild prolongation of bilateral tibial F-wave latency. Fibrillation potentials were seen in the peroneal division of the sciatic nerve with minimal evidence of reinnervation changes to the muscle units. This was indicative of sciatic neuropathy exclusively involving the peroneal division. This localized the lesion to proximal to the short head of the bicep femoris muscle. This led to obtaining advanced imaging consisting of a computed tomography (CT) of the pelvis, which demonstrated a malpositioned acetabular cup screw within the soft tissues adjacent to the sciatic nerve ([Fig. 1]).

Zoom Image
Fig. 1 CT scan of hip showing malpositioned and long acetabular cup screw.

#

Operation

The patient underwent a buttock-level exploration of the sciatic nerve complex. The sciatic nerve was dissected via internal neurolysis into peroneal and tibial divisions at the level of the buttock. The division of the sciatic complex was dissected proximally to the exit of the sciatic from the pelvis. The peroneal portion of the nerve was found to be compromised by the malpositioned screw. There was no neuroma identified at the site of nerve compression, although there was evidence of nerve displacement by the protruding screw. The nerve was stimulated locally and nerve action potentials were recorded proximal and distal to the site of injury. Both peroneal and tibial portions of the nerve were tested separately to avoid false-positive conduction from the tibial division. The intraoperative recordings showed preservation of conduction across the site of nerve impingement ([Fig. 2]).

Zoom Image
Fig. 2 Intraoperative photo showing acetabular screw impinging on the peroneal division of the sciatic nerve. Arrow, THA screw; Asterisk, peroneal division.

The nerve was reflected off the head of the screw and gently moved proximally toward the sciatic notch. An external neurolysis of the peroneal division was performed. When the nerve was free of the screw and protected, a titanium cutting drill bit was used to shorten the screw so that it was flush with the bony interface. Repeated stimulation of the nerve confirmed that action potentials were still able to propagate past the site of injury.


#

Postoperative Course

The patient is now 2 years out of surgery and has demonstrated some recovery of peroneal nerve function, supporting the decision to pursue external neurolysis. The patient's improvement has not been complete and the patient requires an external orthosis.


#
#

Discussion

THA is a widely used procedure for the treatment of end-stage hip arthritis that is able to restore functional ability to hundreds of thousands of patients a year in the United States. Postoperative neurologic injury is a devastating complication with significant morbidity and functional limitations. There is a known risk of immediate neuropathy from mechanisms such as intraoperative compression from retractors, hematoma, limb lengthening, and inappropriate patient positioning. However, there is also a rarer risk of delayed neuropathy after THA that has different causative pathologies. Our findings from the literature suggest that late complications from THA may be more likely due to migration of hardware over time with subsequent nerve compression or reactive mass or fluid collection. In our case, a long, malpositioned screw was found in the soft tissue compressing the peroneal branch of the sciatic nerve.


#

Literature Review

A search of the PubMed database was conducted using the search term “delayed neuropathy after total hip arthroplasty” covering the years 1950 through 2015. Fifteen case reports on 16 patients were selected based on involvement of a neuropathy that appeared after THA.[3] [4] [5] [6] [7] [8] [9] [10] [11] [12]

Patients presenting prior to 1 month included those that developed postoperative hematomas, had poor patient positioning, had previously undiagnosed hereditary neuropathy with liability to pressure palsies (HNPPs), or had anesthetic-induced inflammatory neuropathy and were felt to qualify as early postoperative complications. Delayed onset was defined as those with neuropathies developing over 1 month from surgery. The initial presentations, interventions, and outcomes are outlined in [Table 1].

Table 1

Summary of literature review of cases of delayed neuropathy after total hip arthroplasty

Case report

Time of presentation

Clinical presentation

Workup

Intervention

Identified injury

Outcome

Fokter et al[8]

9 y

P: Left groin and thigh pain radiation to the knee

S: Hypoesthesia in anteromedial thigh

M: Quadriceps weakness

R: Loss of patellar reflex

X-ray: Eccentric location of femoral head in shell showing liner wear

MRI spine: Normal

EMG: Lesion localized to left lumbosacral plexus with denervation in femoral distribution

CT: 13-cm intrapelvic cyst

Lower middle laparotomy and removal of pelvic cyst

Revision hip arthroplasty with allograft used to repair defect

Wear debris mass

Full recovery of function

May et al

4 mo

S: Mild numbness in foot

None

None

Limb lengthening

Full recovery of function

May et al

5 mo

P: Pain in foot

S: Sensory deficit in big toe

EMG

Interpositioning of fat pad between sciatic nerve and acetabular ring

Reinforcement ring implantation and scar tissue

Resolution of pain

Developed foot drop 6 mo after reoperation

Bader et al[4]

S: Numbness in anterior and medial aspect of thigh

M: Weak knee extension

EMG: 60% loss of motor conduction in femoral nerve

Nerve separation from scar tissue, removal of granuloma and acetabular ring

Loosening of acetabular implant and migration, fracture of supplemental screw, granuloma formation

Full recovery of sensory function

Motor improved to 20% of function

Katsimihas et al[9]

5 mo

S: Lateral calf, foot, posterior leg

R: absent ankle jerk

M: Weakness in ankle dorsiflexors, evertors, and invertors

EMG: Sciatic nerve deficit at level of the hip or proximal thigh in tibialis anterior, peroneus longus, and gastrocnemius

MRI: Spine, gluteus, and pelvis unrevealing

AFO

Improvement in muscle strength and sensation, not back to baseline

Fischer et al[7]

7 y

P: Lower buttock, difficulty with ambulation

EMG: Normal

CT: Large fluid collection deep to abductor extending through greater sciatic notch

Arthrogram: Fistula between joint and pelvic fluid collection

L4–5 foraminotomy

IR drainage of fluid collection

Removal of fractured polyethylene liner and use of bone allograft, cyst resection, replacement of hardware

Cyst formation from THA wear debris

Resolution of pain

Able to ambulate unassisted

Stiehl and Stewart[12]

6 mo

P: Left foot

S: Left foot

Bone scan: No increased uptake

EMG: Deficit in gluteus medius, tibialis anterior, flexor digitorum longus, biceps femoris, gastrocnemius

Screw removal, dissection of nerve away from injury site

Pelvic screw migration compressing sciatic nerve

Resolution of pain

Numbness persistent

Motor function improved to 60%

Asnis et al[3]

5 y

P: Buttock and thigh

S: Posterior thigh

M: Hamstring weakness

R: Decreased ankle jerk

X-ray: Normal lumbosacral region; pelvis showing wire migration

Lidocaine injection

Sciatic exploration showing 2 cm wire within sciatic nerve, epineurium incised and wire removed

Migration of trochanteric wire

Full recovery of function

Edwards et al[6]

3 y

P: Buttock, posterior thigh to toe

S: Dorsum of foot and lateral calf

M: Tibialis anterior, extensor digitorum longus, extensor hallicis longus

R: Absent ankle jerk

X-ray: Normal

EMG: Deficit in tibialis anterior, extensor hallicis longus, short head of biceps femoris

Myelogram: Normal

Sciatic nerve exploration; spur of methyl methacrylate found eroding through lateral side of sciatic, neurolysis and shaving down spur

Methyl methacrylate spur

Immediate pain relief

Decrease in area of sensory loss

No motor recover

Casagrande and Danahy[5]

7 mo

P: Foot pain

M: Peroneal weakness

EMG: Deficit in peroneal and tibial distribution

Sciatic nerve block and lumbar sympathetic block

Sciatic exploration showing dense scar tissue, sciatic neurolysis and acrylic mass excision, osteotomy of ischial tuberosity

Acrylic mass, scar tissue

Pain resolved

No motor recovery

Leinung et al[10]

10 y

P: Thigh pain

M: Weakness in femoral distribution

CT: Large pelvic mass

Wide excision of tumor

Inflammatory pseudotumor of iliopsoas

Xu et al

2 y

S: Lateral leg and dorsum of foot

M: Absence of dorsiflexion, weakness in ankle eversion

MRI: Atrophy of extensor muscles

EMG: Deficits in peroneal distribution of sciatic nerve

CT: Displacement of screw

Sciatic exploration with dissection of nerve off of screw; shaving down screw

Screw displacement and compression of sciatic nerve

Persistent motor and sensory loss

Abbreviations: AFO, ankle-foot orthosis; CT, computed tomography; EMG, electromyography; IR, interventional radiology; MRI, magnetic resonance imaging; THA, total hip arthroplasty.


Eleven patients were defined as having late-onset neuropathies. Date of presentation ranged from 4 months to 9 years postoperatively. Presenting symptoms included eight patients with pain, nine with sensory deficits, eight with motor deficits, and four with loss of reflexes. Regarding patient workup, three received hip radiographs, four had CTs, two had magnetic resonance imaging (MRIs), and nine underwent EMGs. Ten patients received operative intervention, whereas one was treated conservatively with a brace and one with no intervention. Mechanisms of injury include three patients with mass formation adjacent to the construct, one patient with limb-lengthening injury, and seven patients with hardware migration and compression. Of those with mass formation next to the construct, one was felt to be inflammatory pseudotumor whereas two were felt to be wear-related cysts caused by metal debris. After intervention, four patients made a full recovery of function, whereas six out of eight patients with preintervention motor deficits had persistent motor deficits and one without preintervention motor deficits developed a foot drop postoperatively. Out of the nine patients with sensory deficits, four had persistent sensory loss after intervention.


#

Evaluation of Delayed Neuropathy

Patients with delayed neuropathy varied in presentation with pain, sensory, and motor symptoms. Most patients were evaluated with an EMG that can objectively quantify degree of motor compromise and aid in lesion localization.

As the causes of delayed nerve injury are largely local anatomical changes, CT and MRI can be helpful in identifying the cause of neuropathy. EMG localization of the level of deficit, combined with screw malposition, suggested that it was the cause of the patient's sensory and motor loss.


#

Conclusion

Delayed neuropathy is a rare complication after primary THA that can be caused by hardware irritation as in the present case. Patients can present with pain, sensory loss, motor loss, and decreased reflexes that are best worked up with EMG to localize the area of neuropathy and imaging to identify the root source. Results from the literature show that operative intervention is often pursued to explore and directly visualize the nerve with limited results in the literature showing modest relief of pain and sensory symptoms and poor restoration of motor function.


#
#

Note

Linda W. Xu and Anand Veeravagu authors contributed equally to this manuscript.


  • References

  • 1 Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 2007; 89 (4) 780-785
  • 2 Brown GD, Swanson EA, Nercessian OA. Neurologic injuries after total hip arthroplasty. Am J Orthop 2008; 37 (4) 191-197
  • 3 Asnis SE, Hanley S, Shelton PD. Sciatic neuropathy secondary to migration of trochanteric wire following total hip arthroplasty. Clin Orthop Relat Res 1985; (196) 226-228
  • 4 Bader R, Mittelmeier W, Zeiler G, Tokar I, Steinhauser E, Schuh A. Pitfalls in the use of acetabular reinforcement rings in total hip revision. Arch Orthop Trauma Surg 2005; 125 (8) 558-563
  • 5 Casagrande PA, Danahy PR. Delayed sciatic-nerve entrapment following the use of self-curing acrylic. A case report. J Bone Joint Surg Am 1971; 53 (1) 167-169
  • 6 Edwards MS, Barbaro NM, Asher SW, Murray WR. Delayed sciatic palsy after total hip replacement: case report. Neurosurgery 1981; 9 (1) 61-63
  • 7 Fischer SR, Christ DJ, Roehr BA. Sciatic neuropathy secondary to total hip arthroplasty wear debris. J Arthroplasty 1999; 14 (6) 771-774
  • 8 Fokter SK, Repse-Fokter A, Takac I. Case report: femoral neuropathy secondary to total hip arthroplasty wear debris. Clin Orthop Relat Res 2009; 467 (11) 3032-3035
  • 9 Katsimihas M, Hutchinson J, Heath P, Smith E, Travlos J. Delayed transient sciatic nerve palsy after total hip arthroplasty. J Arthroplasty 2002; 17 (3) 379-381
  • 10 Leinung S, Schönfelder M, Würl P. [Inflammatory pseudotumor of the ileopsoas muscle with femoral paralysis caused by massive metal abrasion of a hip endoprosthesis]. Chirurg 2002; 73 (7) 725-728
  • 11 May O, Girard J, Hurtevent JF, Migaud H. Delayed, transient sciatic nerve palsy after primary cementless hip arthroplasty: a report of two cases. J Bone Joint Surg Br 2008; 90 (5) 674-676
  • 12 Stiehl JB, Stewart WA. Late sciatic nerve entrapment following pelvic plate reconstruction in total hip arthroplasty. J Arthroplasty 1998; 13 (5) 586-588

Address for correspondence

Anand Veeravagu, MD
Department of Neurosurgery, Stanford University School of Medicine
300 Pasteur Drive, Stanford, CA 94305
United States   

  • References

  • 1 Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 2007; 89 (4) 780-785
  • 2 Brown GD, Swanson EA, Nercessian OA. Neurologic injuries after total hip arthroplasty. Am J Orthop 2008; 37 (4) 191-197
  • 3 Asnis SE, Hanley S, Shelton PD. Sciatic neuropathy secondary to migration of trochanteric wire following total hip arthroplasty. Clin Orthop Relat Res 1985; (196) 226-228
  • 4 Bader R, Mittelmeier W, Zeiler G, Tokar I, Steinhauser E, Schuh A. Pitfalls in the use of acetabular reinforcement rings in total hip revision. Arch Orthop Trauma Surg 2005; 125 (8) 558-563
  • 5 Casagrande PA, Danahy PR. Delayed sciatic-nerve entrapment following the use of self-curing acrylic. A case report. J Bone Joint Surg Am 1971; 53 (1) 167-169
  • 6 Edwards MS, Barbaro NM, Asher SW, Murray WR. Delayed sciatic palsy after total hip replacement: case report. Neurosurgery 1981; 9 (1) 61-63
  • 7 Fischer SR, Christ DJ, Roehr BA. Sciatic neuropathy secondary to total hip arthroplasty wear debris. J Arthroplasty 1999; 14 (6) 771-774
  • 8 Fokter SK, Repse-Fokter A, Takac I. Case report: femoral neuropathy secondary to total hip arthroplasty wear debris. Clin Orthop Relat Res 2009; 467 (11) 3032-3035
  • 9 Katsimihas M, Hutchinson J, Heath P, Smith E, Travlos J. Delayed transient sciatic nerve palsy after total hip arthroplasty. J Arthroplasty 2002; 17 (3) 379-381
  • 10 Leinung S, Schönfelder M, Würl P. [Inflammatory pseudotumor of the ileopsoas muscle with femoral paralysis caused by massive metal abrasion of a hip endoprosthesis]. Chirurg 2002; 73 (7) 725-728
  • 11 May O, Girard J, Hurtevent JF, Migaud H. Delayed, transient sciatic nerve palsy after primary cementless hip arthroplasty: a report of two cases. J Bone Joint Surg Br 2008; 90 (5) 674-676
  • 12 Stiehl JB, Stewart WA. Late sciatic nerve entrapment following pelvic plate reconstruction in total hip arthroplasty. J Arthroplasty 1998; 13 (5) 586-588

Zoom Image
Fig. 1 CT scan of hip showing malpositioned and long acetabular cup screw.
Zoom Image
Fig. 2 Intraoperative photo showing acetabular screw impinging on the peroneal division of the sciatic nerve. Arrow, THA screw; Asterisk, peroneal division.