Subscribe to RSS
DOI: 10.1055/s-0033-1343500
Effects of Flow Patterns and Hemodynamic Force on Vascular Endothelium in the Temporary Arteriovenous Shunt Loop in Rabbits
Publication History
14 December 2012
30 December 2012
Publication Date:
08 April 2013 (online)
Abstract
The purpose of this study was to investigate whether there is a risk of thrombosis in the temporary arteriovenous shunt loop (TAVSL). The authors established a TAVSL model in the rabbit. Experimental groups were divided into non–heparin treated and heparin treated. The maximum blood flow volume, blood viscosity, and radius of curvature were measured, and the Reynolds number and the sheer stress were calculated. Computational fluid dynamics (CFD) was used to predict the flow pattern in the TAVSL, and these predicted data were compared with histological results. Early occlusion was noted in 70% (7/10) of the non–heparin-treated group and 22% (2/9) of the heparin-treated group. CFD analysis predicted a high shear stress at the arterial anastomosis region and the outer luminal surface of the curved section. The intimal structure at the luminal surface of the curved section was extensively lost histologically. In the patent group, severe stenosis of the lumen was noted at the apex of the loop due to an organized thrombus. Thus, thrombosis is likely to occur in the TAVSL due to endothelium injury caused by high shear stress, and this results in the formation of white thrombi at an early stage and an organized thrombus at a late stage.
-
References
- 1 Threlfall GN, Little JM, Cummine J. Free flap transfer—preliminary establishment of an arteriovenous fistula: a case report. Aust N Z J Surg 1982; 52 (2) 182-184
- 2 Acland RD. Refinements in lower extremity free flap surgery. Clin Plast Surg 1990; 17 (4) 733-744
- 3 Ritter EF, Anthony JP, Levin LS , et al. Microsurgical composite tissue transplantation at difficult recipient sites facilitated by preliminary installation of vein grafts as arteriovenous loops. J Reconstr Microsurg 1996; 12 (4) 231-240
- 4 Tanaka Y, Crowe DM, Wagh M, Morrison WA. New source of vein graft for rabbit experimentation. Microsurgery 1999; 19 (4) 167-170
- 5 Freedman AM, Meland NB. Arteriovenous shunts in free vascularized tissue transfer for extremity reconstruction. Ann Plast Surg 1989; 23 (2) 123-128
- 6 Earle AS, Feng LJ, Jordan RB. Long saphenous vein grafts as an aid to microsurgical reconstruction of the trunk. J Reconstr Microsurg 1990; 6 (2) 165-169
- 7 Sørensen JL, Muchardt O, Reumert T. Temporary arteriovenous shunt prior to free flap transfer. Scand J Plast Reconstr Surg Hand Surg 1990; 24 (1) 43-46
- 8 Vlastou C, Earle AS, Jordan R. Vein grafts in reconstructive microsurgery of the lower extremity. Microsurgery 1992; 13 (5) 234-235
- 9 Angel MF, Chang B, Clark N, Wong L, Ringelman P, Manson PN. Further clinical use of the interposition arteriovenous loop graft in free tissue transfers. Microsurgery 1993; 14 (8) 479-481
- 10 Mulholland S, Boyd JB, McCabe S , et al. Recipient vessels in head and neck microsurgery: radiation effect and vessel access. Plast Reconstr Surg 1993; 92 (4) 628-632
- 11 Silveira LF, Patricio JA. Arteriovenous fistula with a saphenous long loop. Microsurgery 1993; 14 (7) 444-445
- 12 Devansh S. Prefabricated recipient vascular pedicle for free composite-tissue transfer in the chronic stage of severe leg trauma. Plast Reconstr Surg 1995; 96 (2) 392-399
- 13 Germann G, Steinau HU. The clinical reliability of vein grafts in free-flap transfer. J Reconstr Microsurg 1996; 12 (1) 11-17
- 14 Lineaweaver W, Hui KCW, Kaufmann D. Cross-facial vein grafting in complicated flap reconstructions of the face and mandible. J Reconstr Microsurg 1997; 13 (8) 545-549
- 15 Karanas YL, Yim KK, Johannet P, Hui K, Lineaweaver WC. Use of 20 cm or longer interposition vein grafts in free flap reconstruction of the trunk. Plast Reconstr Surg 1998; 101 (5) 1262-1267
- 16 Atiyeh BS, Khalil IM, Hussein MK, Al Amm CA, Musharafieh RS. Temporary arteriovenous fistula and microsurgical free tissue transfer for reconstruction of complex defects. Plast Reconstr Surg 2001; 108 (2) 485-488
- 17 Antohi N, Stingu C, Stan V. The use of prefabricated recipient vascular pedicle for free tissue transfer in severe limb injury. The Rom J Plast Surg 2001; 9: 421-425
- 18 Lin CH, Mardini S, Lin YT, Yeh JT, Wei FC, Chen HC. Sixty-five clinical cases of free tissue transfer using long arteriovenous fistulas or vein grafts. J Trauma 2004; 56 (5) 1107-1117
- 19 Brüner S, Bickert B, Sauerbier M, Germann G. Concept of arteriovenous loupes in high-risk free-tissue transfer: history and clinical experiences. Microsurgery 2004; 24 (2) 104-113
- 20 Sunar H, Aygit CA, Afsar Y, Halici U, Duran E. Arterial and venous reconstruction for free tissue transfer in diabetic ischemic foot ulcers. Eur J Vasc Endovasc Surg 2004; 27 (2) 210-215
- 21 Oswald TM, Stover SA, Gerzenstein J , et al. Immediate and delayed use of arteriovenous fistulae in microsurgical flap procedures: a clinical series and review of published cases. Ann Plast Surg 2007; 58 (1) 61-63
- 22 Vogt PM, Steinau HU, Spies M , et al. Outcome of simultaneous and staged microvascular free tissue transfer connected to arteriovenous loops in areas lacking recipient vessels. Plast Reconstr Surg 2007; 120 (6) 1568-1575
- 23 Cavadas PC. Arteriovenous vascular loops in free flap reconstruction of the extremities. Plast Reconstr Surg 2008; 121 (2) 514-520
- 24 Demiri EC, Hatzokos H, Dionyssiou D, Megalopoulos A, Pitoulias G, Papadimitriou D. Single stage arteriovenous short saphenous loops in microsurgical reconstruction of the lower extremity. Arch Orthop Trauma Surg 2009; 129 (4) 521-524
- 25 Davies MG. Intimal hyperplasia: basic response to arterial and vein graft injury and reconstruction. In: Rutherford RB, , ed. Vascular Surgery. 6th ed. Philadelphia: Saunders; 2005: 149-172
- 26 Ishikawa M, Sasajima T, Kubo Y. Re-endothelialisation in autogenous vein grafts. Eur J Vasc Endovasc Surg 1996; 11 (1) 105-111
- 27 Ando J. Perception and response to blood flow by vascular endothelial cells. Jap J Jikken Igaku 1995; 13: 133-138
- 28 Back MR, Cho YI, Crawford DW, Back LH. Fluid particle motion and Lagrangian velocities for pulsatile flow through a femoral artery branch model. J Biomech Eng 1987; 109 (1) 94-101
- 29 Brown EE, Chang WT, Jones NF. Temporary arteriovenous loop between the saphenous vein and the first plantar metatarsal artery in toe-to-hand transfers. J Hand Surg Am 2006; 31 (9) 1543-1545
- 30 Topalan M, Bilgin-Karabulut A, Ermis I. “Extracorporeal loop” (blind loop): an alternative microsurgical technique for prelaminated flap transfer. J Reconstr Microsurg 2002; 18 (3) 155-158 , discussion 159
- 31 Echo A, Bullocks JM. Use of the descending branch of the lateral femoral circumflex vessels as a composite interposition graft in lower extremity reconstruction. Microsurgery 2011; 31 (3) 241-245