Cent Eur Neurosurg 2011; 72(2): 75-77
DOI: 10.1055/s-0030-1267246
Original Article

© Georg Thieme Verlag KG Stuttgart · New York

Use of Antibiotic - Impregnated DuraGen® to Reduce the Risk of Infection in Dura Repair: An In Vitro Study

M. Kaplan1 , B. Akgun1 , K. Demirdag2 , N. Akpolat3 , S. K. Kozan4 , O. Cagasar2 , H. Yakar1
  • 1Firat University, Neurosurgery, Elazig, Turkey
  • 2Firat University, Infectious Diseases and Clinical Microbiology, Elazig, Turkey
  • 3Firat University, Pathology, Elazig, Turkey
  • 4Van State Hospital, Pathology, Van, Turkey
Further Information

Publication History

Publication Date:
22 February 2011 (online)

Abstract

Aim: To investigate the efficacy of antibiotic-impregnated DuraGen® in preventing infection when used for repair of dural defects.

Material and Methods: 2 groups of 7 samples were formed. In the first group, normal DuraGen® samples without antibiotic impregnation and in the second group, DuraGen® samples with antibiotic impregnation (30 mg vancomycin) were used. Staphylococcus aureus (ATCC 25923), and Staphylococcus epidermidis (ATCC 12228) were selected for this study. Antimicrobial efficacy was evaluated by counting the number of colonies on and by measuring the diameter of the inhibition zone around the samples.

Results: There was no zone diameter around the normal DuraGen® for the 2 types of bacteria. There was significant bacterial growth (105) according to the colony count. For antibiotic-impregnated DuraGen®, there was a zone with a mean diameter of 32 mm in the agar with S. aureus and a zone with a mean diameter of 35 mm in the agar with S. epidermidis. Antibiotic-impregnated DuraGen® was quite effective against both microorganisms and there was no bacterial growth according to the bacterial colony count.

Conclusions: In our in vitro study, antibiotic-impregnated DuraGen® material significantly inhibited microorganism growth. Our results show that antibiotic-impregnated DuraGen® has the potential to prevent infection.

References

  • 1 Bassetti S, Hu J, D’Agostino RB. et al . Prolonged antimicrobial activity of a catheter containing chlorhexidine-silver sulfadiazine extends protection against catheter infections in vivo.  Antimicrob Agents Chemother. 2001;  45 1535-1538
  • 2 Berjano R, Vinas FC, Dujovny M. A review of dural substitutes used in neurosurgery.  Crit Rev Neurosurg. 1999;  97 217-222
  • 3 Boop FA, Chadduck WM. Silastic duraplasty in pediatric patients.  Neurosurgery. 1991;  29 785-788
  • 4 Cagavi F, Akalan N, Celik H. et al . Effect of hydrophilic coating on microorganism colonization in silicone tubing.  Acta Neurochir (Wien). 2004;  146 603-610
  • 5 Danish SF, Samdani A, Hanna A. et al . Experience with a cellular human dura and bovine collagen matrix for duraplasty after posterior fossa decompression for Chiari malformations.  J Neurosurg (1 Suppl Pediatrics). 2006;  104 16-20
  • 6 Govender ST, Nathoo N, van Dellen JR. Evaluation of an antibiotic-impregnated shunt system for the treatment of hydrocephalus.  J Neurosurg. 2003;  99 831-839
  • 7 McCall TD, Fults DW, Schmidt RH. Use of resorbable collagen dural substitutes in presence of cranial and spinal infections – report of 3 cases.  Surg Neurol. 2008;  70 92-97
  • 8 Narotam PK, Reddy K, Fewer D. et al . Collagen matrix duraplasty for cranial and spinal surgery: a clinical and imaging study.  J Neurosurg. 2007;  106 45-51
  • 9 Secer HI, Kural C, Kaplan M. et al . Comparison of the efficacies of antibiotic-impregnated and silver-impregnated ventricular catheters on the prevention of infections. An in vitro laboratory study.  Pediatr Neurosurg. 2008;  44 444-447
  • 10 Stendel R, Danne M, Fiss I. et al . Efficacy and safety of a collagen matrix for cranial and spinal dural reconstruction using different fixation techniques.  J Neurosurg. 2008;  109 215-221
  • 11 Tatsui CE, Martinez G, Li X. et al . Evaluation of DuraGen in preventing peridural fibrosis in rabbits.  J Neurosurg Spine. 2006;  4 51-59
  • 12 Vanaclocha V, Saiz-Sapena N. Duraplasty with freeze-dried cadaveric dura versus occipital pericranium for Chiari type I malformation: comparative study.  Acta Neurochir (Wien). 1997;  139 112-119
  • 13 Verheggen R, Schulte-Baumann WJ, Hahm G. et al . A new technique of dural closure-experience with a vicryl mesh.  Acta Neurochir (Wien). 1997;  139 1074-1079
  • 14 Zerris VA, James KS, Roberts JB. et al . Repair of the dura mater with processed collagen devices.  J Biomed Mater Res B Appl Biomater. 2007;  83 (2) 580-588

Correspondence

Dr. M. Kaplan

Firat University

Neurosurgery

Firat Universitesi hastanesi

23200 Elazig

Turkey

Phone: +90/424/233 3555

Fax: +90/424/238 8096

Email: mtkaplan02@hotmail.com

    >