Endoscopy 2022; 54(04): v16
DOI: 10.1055/a-1530-0332
Author commentary

Author commentary on Mihai Ciocîrlan et al.

 

    Mihai Ciocîrlan et al. Monitored needle acceleration in endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic masses improves sample quality and diagnostic accuracy: a randomized trial

    The impact of monitored needle acceleration during EUS-guided fine-needle aspiration was assessed in this study of 51 patients with solid pancreatic masses. Fast passes were associated with improved levels of diagnostic accuracy and a higher frequency of adequate quality scores compared with slow passes, with no difference in the cellularity scores between the two groups.

    Quality:

    #

    Publication History

    Article published online:
    29 March 2022

    © 2022. Thieme. All rights reserved.

    Georg Thieme Verlag KG
    Rüdigerstraße 14, 70469 Stuttgart, Germany