Endoscopy 2019; 51(09): E270-E271
DOI: 10.1055/a-0896-2086
E-Videos
© Georg Thieme Verlag KG Stuttgart · New York

Endoscopic-ultrasound evaluation and fine needle aspiration with a linear echoendoscope in the cecum: it is possible

Spencer Cheng
1   Gastrointestinal Endoscopy Unit, Gastroenterology Department, University of São Paulo Medical School, São Paulo, Brazil
,
Vitor Ottoboni Brunaldi
1   Gastrointestinal Endoscopy Unit, Gastroenterology Department, University of São Paulo Medical School, São Paulo, Brazil
,
Gustavo Luis Rodela Silva
1   Gastrointestinal Endoscopy Unit, Gastroenterology Department, University of São Paulo Medical School, São Paulo, Brazil
,
Carlos Kiyoshi Furuya
1   Gastrointestinal Endoscopy Unit, Gastroenterology Department, University of São Paulo Medical School, São Paulo, Brazil
,
Mauricio Kazuyoshi Minata
1   Gastrointestinal Endoscopy Unit, Gastroenterology Department, University of São Paulo Medical School, São Paulo, Brazil
,
Sergio Eiji Matuguma
1   Gastrointestinal Endoscopy Unit, Gastroenterology Department, University of São Paulo Medical School, São Paulo, Brazil
,
Everson Luiz de Almeida Artifon
2   Department of Surgery, University of São Paulo Medical School, São Paulo, Brazil
› Author Affiliations
Further Information

Corresponding author

Vitor Ottoboni Brunaldi, MD, MSc
Hospital das Clínicas – University of São Paulo Medical School
Dr. Arnaldo Av, 455
01246-903, São Paulo
Brazil   

Publication History

Publication Date:
13 May 2019 (online)

 

Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) is central to the accurate diagnosis of subepithelial lesions. Similarly, staging of early neoplastic lesions is also an important step in deciding the best treatment option [1] [2]. Unfortunately, the oblique endoscopic view of the linear-array echoendoscope precludes routine cecal intubation. Therefore, EUS evaluation in the right colon and cecum is usually restricted to mini-probes and forward-view radial echoendoscopes, which do not allow tissue sampling [3]. We describe a new technique that allows a standard oblique-view linear-array echoendoscope to be used to intubate the cecum and perform EUS-FNA.

We employed a combined overtube–guidewire technique. Firstly, we placed a colonic hydrophilic-coated flexible steel-coiled overtube (Entrada; US Endoscopy) over a standard colonoscope (CF-Q150; Olympus). We then performed a colonoscopy and placed a guidewire (Jagwire; Boston Scientific) into the cecum. The colonoscope was pulled out leaving the guidewire in place. Next, we inserted a standard linear-array echoendoscope (GF UCT-180; Olympus) over the guidewire and through the overtube. Once the colon had been reached, the scope was carefully inserted using the guidewire to secure cecal intubation. Finally, ultrasound interrogation of the subepithelial lesion and EUS-FNA were successfully performed ([Video 1]). In our second patient, we used the same technique to stage an early neoplastic lesion ([Video 1]).

Video 1 The combined overtube–guidewire technique using a linear-array echoendoscope for endoscopic ultrasound-guided evaluation and fine needle aspiration of a cecal subepithelial lesion (Case #1) and for staging of an early neoplastic lesion (Case #2).


Quality:

Using a colonoscope to straighten the sigmoid loops is an important step in correct placement of the overtube. Ultimately, this will allow the echoendoscope to safely reach the descending colon. The next step is the placement of a guidewire into the cecum. This guidewire directs the echoendoscope, helps widen the colonic flexures, and safeguards passage of the scope into the ascending colon and cecum.

EUS-FNA of right colonic submucosal tumors nevertheless remains challenging, but the aforementioned technique seems feasible and reproducible. It may further facilitate the management of subepithelial lesions in the right colon.

Endoscopy_UCTN_Code_TTT_1AS_2AZ

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online.
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos


#

Competing interests

None

  • References

  • 1 Haji A, Adams K, Bjarnason I. et al. High-frequency mini probe ultrasound before endoscopic resection of colorectal polyps – is it useful?. Dis Colon Rectum 2014; 57: 378-382
  • 2 Brunaldi VO, Coronel M, Chacon DA. et al. Subepithelial rectal gastrointestinal stromal tumor - the use of endoscopic ultrasound-guided fine needle aspiration to establish a definitive cytological diagnosis: a case report. J Med Case Rep 2017; 11: 59
  • 3 Diehl DL, Johal AS, Nguyen V-NH. et al. Use of a forward-viewing echoendoscope for evaluation of GI submucosal lesions. Gastrointest Endosc 2012; 75: 428-431

Corresponding author

Vitor Ottoboni Brunaldi, MD, MSc
Hospital das Clínicas – University of São Paulo Medical School
Dr. Arnaldo Av, 455
01246-903, São Paulo
Brazil   

  • References

  • 1 Haji A, Adams K, Bjarnason I. et al. High-frequency mini probe ultrasound before endoscopic resection of colorectal polyps – is it useful?. Dis Colon Rectum 2014; 57: 378-382
  • 2 Brunaldi VO, Coronel M, Chacon DA. et al. Subepithelial rectal gastrointestinal stromal tumor - the use of endoscopic ultrasound-guided fine needle aspiration to establish a definitive cytological diagnosis: a case report. J Med Case Rep 2017; 11: 59
  • 3 Diehl DL, Johal AS, Nguyen V-NH. et al. Use of a forward-viewing echoendoscope for evaluation of GI submucosal lesions. Gastrointest Endosc 2012; 75: 428-431