Background Intima-to-intima microanastomotic vascular remodeling was explored, utilizing a polylactide-caprolactone absorbable vein coupler model (PAVCM), which was designed to simulate a non-absorbable counterpart system with the sole exception of being absorbable.

Methods Six New Zealand white rabbits were used. After transection of the jugular vein, 2 PAVCMs were placed, 1 at each transected end. The stumps were slipped through the PAVCMs, and the venous wall was everted 90° to achieve intima-to-intima contact. Reanastomosis of the transected jugular vein was performed bilaterally in 3 rabbits. In the other 3 rabbits, the jugular vein (20 mm) harvested from one side was interpositionally grafted to the jugular vein on the opposite side to ease the anastomotic tension. Patency testing, ultrasonography, and histologic assessments were conducted postoperatively at weeks 2, 4, 12, 16, 22, and 26.

Results All anastomotic sites were patent, without stenosis, occlusion, or dilatation. In the histologic sections, immature endothelial regeneration was observed at week 2, which was completed by week 4. Regeneration of the tunica media was noted at week 12. Between week 22 and week 26, the tunica media fully regenerated and the coupler dissipated entirely.

Conclusions Despite the absence of a coupler to act as an anastomotic buttress, the structure and function of all the vessels appeared normal, even histologically. These outcomes are true milestones in the development of an absorbable vein coupler.

This article was presented at the Second Research and Reconstructive Forum of the Korean Society of Plastic and Reconstructive Surgeons on June 1-2, 2012, in Gwangju, Korea.




Publication History

Received: 25 August 2016

Accepted: 02 January 2017

Article published online:
20 April 2022

© 2017. The Korean Society of Plastic and Reconstructive Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonCommercial License, permitting unrestricted noncommercial use, distribution, and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes. (https://creativecommons.org/licenses/by-nc/4.0/)

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • REFERENCES

  • 1 Nakayama K, Yamamoto K, Tamiya T. A new simple apparatus for anastomosis of small vessels: preliminary report. J Int Coll Surg 1962; 38: 12-26
  • 2 Ostrup LT, Berggren A. The UNILINK instrument system for fast and safe microvascular anastomosis. Ann Plast Surg 1986; 17: 521-525
  • 3 Berggren A, Ostrup LT, Lidman D. Mechanical anastomosis of small arteries and veins with the unilink apparatus: a histologic and scanning electron microscopic study. Plast Reconstr Surg 1987; 80: 274-283
  • 4 Ardehali B, Morritt AN, Jain A. Systematic review: anastomotic microvascular device. J Plast Reconstr Aesthet Surg 2014; 67: 752-755
  • 5 Yap LH, Constantinides J, Butler CE. Venous thrombosis in coupled versus sutured microvascular anastomoses. Ann Plast Surg 2006; 57: 666-669
  • 6 Denk MJ, Longaker MT, Basner AL. et al. Microsurgical reconstruction of the lower extremity using the 3M microvascular coupling device in venous anastomoses. Ann Plast Surg 1995; 35: 601-606
  • 7 Kubo T, Kitamura N, Onoda M. et al. Exposure of a microvascular anastomotic coupler in head and neck reconstruction: a case report. Eplasty 2014; 14: e18
  • 8 Zomerlei TA, Komorowska-Timek E. Venous coupler migration: a near miss. Microsurgery 2014; 34: 331-332
  • 9 Hong C, Yeo H, Son D. Vascular remodeling with a microvascular anastomotic coupler system: a case report. Arch Reconstr Microsurg 2015; 24: 20-23
  • 10 Kind GM, Buncke GM, Buncke HJ. Foreign-body sensation following 3M coupler use in the hand. Ann Plast Surg 1996; 37: 418-421
  • 11 Bertleff MJ, Meek MF, Nicolai JP. A prospective clinical evaluation of biodegradable neurolac nerve guides for sensory nerve repair in the hand. J Hand Surg Am 2005; 30: 513-518
  • 12 Den Dunnen WF, Meek MF, Robinson PH. et al. Peripheral nerve regeneration through P(DLLA-epsilon-CL) nerve guides. J Mater Sci Mater Med 1998; 9: 811-814
  • 13 Morecraft R, Blair WF, Chang L. Histopathology of microvenous repair. Microsurgery 1985; 6: 219-228
  • 14 Chow SP. The histopathology of microvascular anastomosis: a study of the incidence of various tissue changes. Microsurgery 1983; 4: 5-9
  • 15 Daniel RK, Lidman D. The normal healing process of microvascular anastomoses. Scand J Plast Reconstr Surg 1981; 15: 103-110
  • 16 Li YN, Wood MB. End-to-side-anastomosis in the dog using the 3M precise microvascular anastomotic system: a comparative study. J Reconstr Microsurg 1991; 7: 345-350
  • 17 Ragnarsson R, Berggren A, Ostrup LT. Long term evaluation of the unilink anastomotic system: a study with light and scanning electron microscopy. Scand J Plast Reconstr Surg Hand Surg 1992; 26: 167-171
  • 18 Blair WF, Morecraft RJ, Steyers CM. et al. A microvascular anastomotic device: Part II. A histologic study in arteries and veins. Microsurgery 1989; 10: 29-39
  • 19 Daniel RK, Olding M. An absorbable anastomotic device for microvascular surgery: experimental studies. Plast Reconstr Surg 1984; 74: 329-336
  • 20 Qu W, Muneshige H, Ikuta Y. An absorbable pinned-ring device for microvascular anastomosis of vein grafts: exprerimental stuies. Microsurgery 1999; 19: 128-134
  • 21 Joji S, Muneshige H, Ikuta Y. Experimental study of mechanical microvascular anastomosis with new biodegradable ring device. Br J Plast Surg 1999; 52: 559-564
  • 22 Maxwell GP, Szabo Z, Buncke Jr HJ. Aneurysms after microvascular anastomoses: incidence and pathogenesis in experimental animals. Plast Reconstr Surg 1979; 63: 824-829
  • 23 Lykoudis EG, Papanikolaou GE, Katsikeris NF. Microvascular anastomotic aneurysms in the clinical setting: case report and review of the literature. Microsurgery 2009; 29: 293-298
  • 24 Ceulemans P, Van Landuyt K, Hamdi M. et al. Complete survival of a free flap after early pseudoaneurysm formation and pedicle thrombosis. Ann Plast Surg 2001; 47: 332-335
  • 25 Borja-Morant A, Navarro-Vila C, Cuesta-Gil M. et al. Experimental evaluation and clinical use in the head and neck of a 3M/Precise microvascular anastomotic device. J Craniomaxillofac Surg 1995; 23: 305-311