RSS-Feed abonnieren
DOI: 10.5999/aps.2015.42.6.769
Stabilizing Morbidity and Predicting the Aesthetic Results of Radial Forearm Free Flap Donor Sites
Background The radial forearm flap is a versatile, widely used flap. However, the possibility of donor site complications has led to concern over its use. Some surgeons prefer using other flaps whose donor sites can be closed primarily with less morbidity, including avoiding unpleasant scarring. However, in our experience, donor site stability of the radial forearm flap can be reliably achieved by using well-implemented specific procedures. Here, we present a collection of donor site cases of the radial forearm flap and investigate factors that affect the aesthetic results as the basis for a reference for selecting a radial forearm flap.
Methods In this retrospective study, we reviewed 171 cases in which a radial forearm flap was used for free tissue transfer after resecting head and neck cancer. We focused on donor site morbidity rates. Each operation involved a detailed procedure designed to minimize donor site morbidity. Moreover, statistical investigations were conducted for 22 cases to determine factors affecting the scar appearance.
Results Only one case developed total skin graft necrosis as a major complication. Scar-related aesthetic results were acceptable, and the body-mass index, body weight, diabetes, and cardiac problems were significant factors related to the appearance of scars.
Conclusions Performing the radial forearm flap using a well-implemented detailed technique helps achieve acceptable donor site morbidity results. The aesthetic results were more promising for patients without excess body weight, diabetes, or cardiac problems. Therefore, anxiety about donor site morbidity should not be a reason to avoid selecting the radial forearm flap in suitable patients.
Publikationsverlauf
Eingereicht: 27. März 2015
Angenommen: 29. Mai 2015
Artikel online veröffentlicht:
05. Mai 2022
© 2015. The Korean Society of Plastic and Reconstructive Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonCommercial License, permitting unrestricted noncommercial use, distribution, and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes. (https://creativecommons.org/licenses/by-nc/4.0/)
Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
-
References
- 1 Yang G, Chen B, Gao W. et al. Forearm free skin flap transplantation. Natl Med J China 1981; 61: 139-141
- 2 Evans GR, Schusterman MA, Kroll SS. et al. The radial forearm free flap for head and neck reconstruction: a review. Am J Surg 1994; 168: 446-450
- 3 Richardson D, Fisher SE, Vaughan ED. et al. Radial forearm flap donor-site complications and morbidity: a prospective study. Plast Reconstr Surg 1997; 99: 109-115
- 4 de Bree R, Hartley C, Smeele LE. et al. Evaluation of donor site function and morbidity of the fasciocutaneous radial forearm flap. Laryngoscope 2004; 114: 1973-1976
- 5 McGregor AD. The free radial forearm flap: the management of the secondary defect. Br J Plast Surg 1987; 40: 83-85
- 6 Demirkan F, Chen HC, Wei FC. et al. The versatile anterolateral thigh flap: a musculocutaneous flap in disguise in head and neck reconstruction. Br J Plast Surg 2000; 53: 30-36
- 7 Kuo YR, Jeng SF, Kuo MH. et al. Free anterolateral thigh flap for extremity reconstruction: clinical experience and functional assessment of donor site. Plast Reconstr Surg 2001; 107: 1766-1771
- 8 Quillen CG. Latissimus dorsi myocutaneous flaps in head and neck reconstruction. Plast Reconstr Surg 1979; 63: 664-670
- 9 Hekner DD, Abbink JH, van Es RJ. et al. Donor-site morbidity of the radial forearm free flap versus the ulnar forearm free flap. Plast Reconstr Surg 2013; 132: 387-393
- 10 Kim SW, Park SH, Koo SH. et al. Clinical applications of the radial forearm flap. J Korean Soc Plast Reconstr Surg 1997; 24: 1090-1099
- 11 Wilson JA, Clark JJ. Obesity: impediment to postsurgical wound healing. Adv Skin Wound Care 2004; 17: 426-435
- 12 Penington AJ, Morrison WA. Skin graft failure is predicted by waist-hip ratio: a marker for metabolic syndrome. ANZ J Surg 2007; 77: 118-120
- 13 Fearmonti R, Bond J, Erdmann D. et al. A review of scar scales and scar measuring devices. Eplasty 2010; 10: e43
- 14 Duncan JA, Bond JS, Mason T. et al. Visual analogue scale scoring and ranking: a suitable and sensitive method for assessing scar quality. Plast Reconstr Surg 2006; 118: 909-918
- 15 Micomonaco DC, Fung K, Mount G. et al. Development of a new visual analogue scale for the assessment of area scars. J Otolaryngol Head Neck Surg 2009; 38: 77-89
- 16 Fenton OM, Roberts JO. Improving the donor site of the radial forearm flap. Br J Plast Surg 1985; 38: 504-505
- 17 Wells MD, Kirn DS. A new method of skin-graft stabilization: the Reston technique. Ann Plast Surg 1995; 34: 554-556
- 18 Saltz R, Bowles BJ. Reston: an alternate method of skin graft fixation. Plast Reconstr Surg 1997; 99: 601-602
- 19 Lutz BS, Wei FC, Chang SC. et al. Donor site morbidity after suprafascial elevation of the radial forearm flap: a prospective study in 95 consecutive cases. Plast Reconstr Surg 1999; 103: 132-137
- 20 Toschka H, Feifel H, Erli HJ. et al. Aesthetic and functional results of harvesting radial forearm flap, especially with regard to hand function. Int J Oral Maxillofac Surg 2001; 30: 42-48
- 21 Bootz F, Biesinger E. Reduction of complication rate at radial forearm flap donor sites. ORL J Otorhinolaryngol Relat Spec 1991; 53: 160-164
- 22 Swanson E, Boyd JB, Manktelow RT. The radial forearm flap: reconstructive applications and donor-site defects in 35 consecutive patients. Plast Reconstr Surg 1990; 85: 258-266
- 23 McCarthy JG. Plastic surgery. Philadelphia: Saunders; 1990
- 24 Ragnell A. The secondary contracting tendency of free skin grafts; an experimental investigation on animals. Br J Plast Surg 1952; 5: 6-24