CC BY-NC-ND 4.0 · World J Nucl Med 2021; 20(03): 247-252
DOI: 10.4103/wjnm.WJNM_123_20
Original Article

The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice

Kalpna Prasad
Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland, USA
,
Chad C. Adams
Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland, USA
,
Eiping Quang
Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland, USA
,
Justin Taylor
Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland, USA
,
Derek J. Stocker
Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland, USA
› Author Affiliations

Abstract

Cadmium Zinc Telluride (CZT) crystal-based myocardial perfusion imaging (MPI) cameras have increased count sensitivity compared to Anger cameras and can be used to lower either the injected activity or the image acquisition time. Institutions adopting CZT cameras need to decide whether to lower the injected activity or imaging time or attempt to lower both with a compromise. The aim of our study was to compare the scan time required to obtain similar count images using high activity protocol (HAP) versus low activity protocol (LAP) stratified by body mass index (BMI) and assess the impact on effective dose and our clinic workflow. Using a CZT camera, a cohort of 100 consecutive clinical patients imaged with LAP rest-stress MPI with approximately 185 MBq and 555 MBq activity was retrospectively compared to a similar cohort of 100 consecutive clinical patients imaged with HAP rest-stress MPI using approximately 370 MBq and 1110 MBq. Administered activity and BMI both had a statistically significant effect on scan time and radiation effective dose. LAP scans took an average of 9 min longer than HAP scans overall, P < 0.0001 and larger BMIs took longer than smaller BMIs, P < 0.0001. In addition, scan times were longer in men than women, P = 0.007. Effective dose was inversely proportional to BMI with an overall decrease of approximately 50% comparing LAP to HAP. For the same CZT camera, the LAP increased scan time while lowering the radiation effective dose when compared to HAP. The increase in scan time increased proportionally to BMI. The effective dose was inversely proportional to BMI. This increase in time did not have a significant impact on our local workflow, but its implications should be considered in the setting of LAP implementation, especially in obese or high patient volume practices.

Financial support and sponsorship

Nil.




Publication History

Received: 26 August 2020

Accepted: 04 April 2021

Article published online:
24 March 2022

© 2021. Sociedade Brasileira de Neurocirurgia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commecial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Andrus BW, Welch HG. Medicare services provided by cardiologists in the United States: 1999-2008. Circ Cardiovasc Qual Outcomes 2012;5:31-6.
  • 2 Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 2009;361:849-57.
  • 3 Dorbala S, Di Carli MF, Delbeke D, Abbara S, DePuey EG, Dilsizian V, et al. SNMMI/ASNC/SCCT Guideline for cardiac SPECT/CT and PET/CT 1.0. J Nucl Med 2013;54:1485-507.
  • 4 Berrington de Gonzalez A, Kim KP, Smith-Bindman R, McAreavey D. Myocardial perfusion scans: Projected population cancer risks from current levels of use in the United States. Circulation 2010;122:2403-10.
  • 5 Berrington de González A, Mahesh M, Kim KP, Bhargavan M, Lewis R, Mettler F, et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 2009;169:2071-7.
  • 6 Smith-Bindman R, Lipson J, Marcus R, Kim KP, Mahesh M, Gould R, et al. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 2009;169:2078-86.
  • 7 National Research Council. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2. Washington, DC: The National Academies Press; 2006. p. 65-90.
  • 8 Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 Appropriate Use Criteria for Cardiac Radionuclide Imaging: A Report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. J Am Coll Cardiol 2009;53:2201-29.
  • 9 Garcia E. Dedicated Solid-State Cardiac Systems for Myocardial Perfusion Imaging Image Wisely. Available from: https://www.imagewisely.org/Imaging-Modalities/Nuclear-Medicine/Dedicated-Solid-State-Cardiac-Systems. [Last accessed on 2018 Jun 01,.[Last accessed on 2020 Dec 30].
  • 10 Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, et al. Recommendations for reducing radiation exposure in myocardial perfusion imaging. J Nucl Cardiol 2010;17:709-18.
  • 11 Garcia EV, Faber TL, Esteves FP. Cardiac dedicated ultrafast SPECT cameras: New designs and clinical implications. J Nucl Med 2011;52:210-7.
  • 12 Herzog BA, Buechel RR, Katz R, Brueckner M, Husmann L, Burger IA, et al. Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: Optimized protocol for scan time reduction. J Nucl Med 2010;51:46-51.
  • 13 Oddstig J, Hedeer F, Jögi J, Carlsson M, Hindorf C, Engblom H. Reduced administered activity, reduced acquisition time, and preserved image quality for the new CZT camera. J Nucl Cardiol 2013;20:38-44.
  • 14 van Dijk JD, Jager PL, Ottervanger JP, Slump CH, de Boer J, Oostdijk AH, et al. Minimizing patient-specific tracer dose in myocardial perfusion imaging using CZT SPECT. J Nucl Med Technol 2015;43:36-40.
  • 15 Nkoulou R, Pazhenkottil AP, Kuest SM, Ghadri JR, Wolfrum M, Husmann L, et al. Semiconductor detectors allow low-dose-low-dose 1-day SPECT myocardial perfusion imaging. J Nucl Med 2011;52:1204-9.
  • 16 Einstein AJ, Blankstein R, Andrews H, Fish M, Padgett R, Hayes SW, et al. Comparison of image quality, myocardial perfusion, and LV function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: The MILLISIEVERT study. J Nucl Med 2014;55:1430.
  • 17 Nakazato R, Berman DS, Hayes SW, Fish M, Padgett R, Xu Y, et al. Myocardial perfusion imaging with a solid-state camera: Simulation of a very low dose imaging protocol. J Nucl Med 2013;54:373-9.
  • 18 RADAR Medical Procedure Radiation Dose Calculator and Consent Language Generator. Available from: https://www.doseinfo-radar.com/RADARDoseRiskCalc.html..[Last accessed on2018 Jun 01].
  • 19 Ben-Haim S, Almukhailed O, Neill J, Slomka P, Allie R, Shiti D, et al. Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera. J Nucl Cardiol 2014;21:478-85.
  • 20 Einstein AJ. Multiple opportunities to reduce radiation dose from myocardial perfusion imaging. Eur J Nucl Med Mol Imaging 2013;40:649-51.