CC BY-NC-ND 4.0 · J Lab Physicians 2017; 9(04): 260-263
DOI: 10.4103/JLP.JLP_141_16
Original Article

Correlations between gingival crevicular blood glucose and capillary blood glucose: A preliminary report

Siluvai Sibyl
Department of Public Health Dentistry, SRM Kattankulathur Dental College and Hospital, Chennai, Tamil Nadu, India
,
Darshana Bennadi
Department of Public Health Dentistry, Sree Siddhartha Dental College and Hospital, Tumkur, India
,
Nandita Kshetrimayum
Department of Public Health Dentistry, Regional Institute of Medical sciences, Dental College, Lamphelpat, Imphal, West Manipur, India
,
Maurya Manjunath
Department of Public Health Dentistry, JSS Dental College and Hospital, Mysore, Karnataka, India
› Author Affiliations
Financial support and sponsorship: Nil.

Abstract

INTRODUCTION: Oral health plays an important role for screening of many systemic diseases. Hence, dentists play an important role in screening for systemic diseases as well. Early diagnosis of any systemic diseases can prevent long‑term complications. Diabetic is one of the common chronic diseases. Hence, the study had been undertaken to evaluate whether gingival crevicular blood (GCB) can be used to screen for diabetes during routine oral health checkups.

MATERIAL AND METHODS: This analytical study included thirty participants who visited the Department of Periodontics, who fulfilled inclusion criteria and were willing to participate. Blood samples were collected by finger stick method and periodontal probing. The glucose levels of both the samples were estimated using glucometer and correlated the levels from both the methods.

RESULTS: Correlation between capillary finger stick blood glucose and GCB glucose was high (0.97) and was significant at 0.01 level.

CONCLUSION: Blood oozing during routine periodontal examination can be used for diabetes mellitus screening in dental office.



Publication History

Received: 14 October 2016

Accepted: 04 July 2017

Article published online:
19 February 2020

© 2017.

Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India

 
  • References

  • 1 Agarwal AA, Jadhav PR, Deshmukh YA. Prescribing pattern and efficacy of anti-diabetic drugs in maintaining optimal glycemic levels in diabetic patients. J Basic Clin Pharm 2014;5:79-83.
  • 2 Joshi SR, Parikh RM. India – Diabetes capital of the world: Now heading towards hypertension. J Assoc Physicians India 2007;55:323-4.
  • 3 Beikler T, Kuczek A, Petersilka G, Flemming TF. In-dental office screening for diabetes mellitus using gingival crevicular blood. J Clin Periodontol 2002;29:216-8.
  • 4 Pramod K, Panseriya BJ, Abhishek B. Gingival crevicular blood: A fast, safe, noninvasive and chair-side method of diabetic screening. Int J Sci Study 2013;1:26-31.
  • 5 Srikumar P, Hema S, Amrita D. Reliability of using gingival crevicular blood in the diagnosis of diabetes. JIADS 2010;1:16-8.
  • 6 Pushparani DS. High acid phosphatase level in the gingival tissues of periodontitis subjects. J Basic Clin Pharm 2015;6:59-63.
  • 7 Centers for Disease Control and Prevention. National Diabetes Fact Sheet; 2007. Available from: http://www.cdc.gov/diabetes/pubs/pdf/ndfs_2001.pdf. [Last accessed on 2016 Nov 18].
  • 8 Bjelland S, Bray P, Gupta N, Hirsch R. Dentists, diabetes and periodontitis. Aust Dent J 2002;47:202-7.
  • 9 Serota K. Blood from Periodontal Disease Can Be Used to Screen for Diabetes. Available from: http://www.blogohj.oralhealthjournal.com. [Last accessed on 2016 Nov 18].
  • 10 Strauss SM, Wheeler AJ, Russell SL, Brodsky A, Davidson RM, Gluzman R, et al. The potential use of gingival crevicular blood for measuring glucose to screen for diabetes: An examination based on characteristics of the blood collection site. J Periodontol 2009;80:907-14.
  • 11 Gillis M, Saxon S. Dentistry in diabetes; diagnosis and management. Diabetes Voice 2003;48:14-7. Available from: http://www.diabetesnsw.com.au/PDFs/About_Diabetes_PDFs/DentalHealth.pdf.
  • 12 Kaur H, Jain S, Bansal S. Minimal invasive chair side procedure for the estimation of glucose level using gingival crevicular blood. Indian J Dent Sci 2012;4:43.
  • 13 Gupta H, Arora R, Kamboj M. The authenticity of use of gingival crevicular blood as an early indicator of elevated systemic blood glucose levels in undiagnosed diabetes mellitus. Indian J Dent Sci 2012;4:1.
  • 14 Bhavsar MV, Brahmbhatt NA, Sahayata V, Bhavsar NV. Gingival crevicular blood for screening of blood glucose level in patients with and without diabetes: A chair-side test. Int J Dent Hyg 2016;14:92-7.
  • 15 Internet-SKUP/2010/81. Accessed from: http://www.skup.nu/GetFile.ashx?fileid=457. [Last accessed on 2016 Nov 18].
  • 16 Accu-Chek Aviva-Skup. Available from: http://www.skup.dk/files/5/skup_2013_98_accu_chek_aviva.pdf. [Last accessed on 2016 Nov 18].
  • 17 Kandwal A, Batra M. Gingival crevicular blood as a screening tool for diabetic patient: A randomized clinical trial. Ann Dent Spec 2014;2:6-8. Available from: http://www.annalsofdentalspecialty.net.inInternet. [Last accessed on 2016 Nov 18].
  • 18 Nishimura F, Takahashi K, Kurihara M, Takashiba S, Murayama Y. Periodontal disease as a complication of diabetes mellitus. Ann Periodontol 1998;3:20-9.
  • 19 Terry DR. Periodontal Management of the patient with diabetes mellitus. Periodontology 2000;23:63-72.
  • 20 Katz J. Elevated blood glucose levels in patients with severe periodontal disease. J Clin Periodontol 2001;28:710-2.
  • 21 Lösche W, Karapetow F, Pohl A, Pohl C, Kocher T. Plasma lipid and blood glucose levels in patients with destructive periodontal disease. J Clin Periodontol 2000;27:537-41.
  • 22 Strauss SM, Russell S, Wheeler A, Norman R, Borrell LN, Rindskopf D, et al. The dental office visit as a potential opportunity for diabetes screening: An analysis using NHANES 2003-2004 data. J Public Health Dent 2010;70:156-62.
  • 23 Kaur H, Singh B, Sharma A. Assessment of blood glucose using gingival crevicular blood in diabetic and non-diabetic patients: A chair side method. J Clin Diagn Res 2013;7:3066-9.
  • 24 Müller HP, Behbehani E. Methods for measuring agreement: Glucose levels in gingival crevice blood. Clin Oral Investig 2005;9:65-9.
  • 25 Müller HP, Behbehani E. Screening of elevated glucose levels in gingival crevice blood using a novel, sensitive self-monitoring device. Med Princ Pract 2004;13:361-5.
  • 26 Robert CP, John WR, William I, Paulette S, William JK. Gingival crevicular blood for assessment of blood glucose in diabetic patients J Periodontol 1993;64:666-72.
  • 27 Ashish B, Singh R, Atul S, Lehl SS. Towards lesser pain during blood glucose estimation. Int J Diab Dev Ctries 2000;20:125-6.
  • 28 Kandwal A, Batra M. Gingival crevicular blood as a screening tool for diabetic patient: A randomized clinical trial. Ann Dent Speciality 2014;2:6-8.
  • 29 Debnath P, Govila V, Sharma M, Saini A, Pandey S. Glucometric assessment of gingival crevicular blood in diabetic and non-diabetic patients: A randomized clinical trial. J Oral Biol Craniofac Res 2015;5:2-6.
  • 30 Preshaw PM, Alba AL, Herrera D, Jepsen S, Konstantinidis A, Makrilakis K, et al. Periodontitis and diabetes: A two-way relationship. Diabetologia 2012;55:21-31.
  • 31 Salvi GE, Yalda B, Collins JG, Jones BH, Smith FW, Arnold RR, et al. Inflammatory mediator response as a potential risk marker for periodontal diseases in insulin-dependent diabetes mellitus patients. J Periodontol 1997;68:127-35.
  • 32 Engebretson SP, Hey-Hadavi J, Ehrhardt FJ, Hsu D, Celenti RS, Grbic JT, et al. Gingival crevicular fluid levels of interleukin-1beta and glycemic control in patients with chronic periodontitis and type 2 diabetes. J Periodontol 2004;75:1203-8.