Summary
Objectives: Introduction of the Sirius® canine total elbow arthroplasty system, and presentation of the results of a passive range-of-motion analysis based on ex vivo kinematic studies pre-and post-implantation.
Materials and methods: Thoracic limbs (n = 4) of medium sized dogs were harvested by forequarter amputation. Plain orthogonal radiographs of each limb were obtained preand post-implantation. Limbs were prepared by placement of external fixator pins and Kirschner wires into the humerus and radius. Each limb was secured into a custom-made box frame and retro-reflective markers were placed on the exposed ends of the pins and wires. Each elbow was manually moved through five ranges-of-motion manoeuvres. Data collected included six trials of i) full extension to full flexion and ii) pronation and supination in 90° flexion; a three-dimensional motion capture system was used to collect and analyse the data. The Sirius elbow prosthesis was subsequently implanted and the same measurements were repeated. Data sets were tested for normality. Paired t-tests were used for comparison of pre- and post-implantation motion parameters.
Results: Kinematic analysis showed that the range-of-motion (mean and SD) for flexion and extension pre-implantation was 115° ± 6 (range: 25° to 140°). The range-of-motion in the sagittal plane post-implantation was 90° ± 4 (range: 36° to 130°) and this reduction was significant (p = 0.0001). The ranges-of-motion (mean and SD) for supination and pronation at 90° were 50° ± 5, whereas the corresponding mean ranges-of-motion post-implantation were 38° ± 6 (p = 0.0188).
Conclusion: Compared to a normal elbow, the range-of-motion was reduced. Post- implantation, supination and pronation range-of-motion was significantly reduced at 90° over pre-implantation values.
Clinical relevance: These results provide valuable information regarding the effect of the Sirius system on ex vivo kinematics of the normal canine elbow joint. Further, this particular ex vivo model allowed for satisfactory and repeatable kinematic analysis.
-
References
- 1 Griffon DJ. Surgical Diseases of the Elbow. In Tobias KM, Johnston SA. editors Veterinary Surgery Small Animal. Volume One. St. Louis, MO: Elsevier Saunders; 2012: 724-751.
- 2 Michelsen J. Canine elbow dysplasia: Aetiopathogenesis and current treatment recommendations. Vet J 2013; 196: 12-19.
- 3 Joaquin Sanchez-Sotelo. Total elbow arthroplasty. The Open Orthopaedics Journal 2011; 5: 115-123.
- 4 Whittick WG, Bonar CJ, Reeve-Newson JA. Prosthesis for elbow fracture. Can Vet J 1964; 5: 56.
- 5 Dejardin L, Guillou RP. Total Elbow Replacement. In Tobias KM, Johnston SA. editors Veterinary Surgery Small Animal. Volume One. St. Louis, MO: Elsevier Saunders; 2012: 752-759.
- 6 Conzemius MG, Aper RL. Development and evaluation of semiconstrained arthroplasty for the treatment of elbow osteoarthritis in the dog. Vet Comp Orthop Traumatol 1998; 11: A54.
- 7 Conzemius MG, Aper RL, Hill CM. Evaluation of a canine total-elbow arthroplasty system: a preliminary study in normal dogs. Vet Surg 2001; 30: 11-20.
- 8 Conzemius MG, Aper RL, Corti LB. Short-term outcome after total elbow arthroplasty in dogs with severe, naturally occurring osteoarthritis. Vet Surg 2003; 32: 545-552.
- 9 Innes JF, Pettitt RA, Smirthwaite P. Development of the Sirius® canine total elbow prosthesis. Presented at: BVOA, Spring Scientific Meeting. 2011. March Birmingham, United Kingdom:
- 10 Jaegger G, Marcellin-Little DJ, Levine D. Reliability of goniometry in Labrador Retrievers. Am J Vet Res 2002; 63: 979-986.
- 11 Guillou RP, Déjardin LM, Bey MJ. et al. Three dimensional kinematics of the normal canine elbow at the walk and trot. American College of Veterinary Surgeons Veterinary Symposium; 2001 November 3-5; Chicago, Illinois. Vet Surg 2011; 40: E30.
- 12 Carr JG, Millis DL, Weng HY. Exercises in canine physical rehabilitation: range of motion of the forelimb during stair and ramp ascent. J Small Anim Pract 2013; 54: 409-413.
- 13 Brady RB, Sidiropoulos AN, Bennett HJ. et al. Evaluation of gait-related variables in lean and obese dogs at a trot. Am J Vet Res 2013; 74: 757-762.
- 14 Universität Leipzig. Fluokin Flouroscopic Kinematography. Three-dimensional kinematics of the normal and dysplastic canine elbow joint [Website page]. Available from. http://www.fluokin.de/projekte/ed/index.html
- 15 Farrell M, Draffan D, Gemmill T. et al. In vitro validation of a technique for assessment of canine and feline elbow joint collateral ligament integrity and description of a new method for collateral ligament prosthetic replacement. Vet Surg 2007; 36: 548-556.
- 16 Clements DN, Owen MR, Carmichael S. et al. Kinematic analysis of the gait of 10 Labrador retrievers during treadmill locomotion. Vet Rec 2005; 156: 478-481.
- 17 Holler PJ, Brazda V, Dal-Bianco B. et al. Kinematic motion analysis of the joints of the forelimbs and hind limbs of dogs during walking exercise regimens. Am J of Vet Res 2010; 71: 734-740.
- 18 Smith GK, LaFond E, Gregor TP. et al. Within- and between-examiner repeatability of distraction indices of the hip joints in dogs. Am J Vet Res 1997; 58: 1076-1077.
- 19 Bitton E, Joseph R, Portman L. et al. The effect of extension and loading of the carpus on radial rotation. Vet Surg 2013; 42: 909-917.
- 20 Talcott KW, Schulz KS, Kass PH. et al. In vitro biomechanical study of rotational stabilizers of the canine elbow joint. Am J Vet Res 2002; 63: 1520-1526.
- 21 Burton NJ, Ellis JR, Burton KJ. et al. An ex vivo investigation of the effect of the TATE canine elbow arthroplasty system on kinematics of the elbow. J Small Anim Pract 2013; 54: 240-247.