Summary
Introduction: The military police are a population exposed to noise impact due to training with firearms.
Objective: To investigate the audiological profile of the military police in São Paulo state, and to correlate the age and duration of exposure and audiological findings.
Method: In this study of case series, cross-sectional audiological evaluation was performed in 200 police officers being 169 (84.5%) were male and 31 (15.5%) females, aged between 25 and 45 years (mean 38.83 ± 5.05), average service time of 16.80 ± 6.27 years.
Results: The main complains were: tinnitus (n = 52/26%), hearing loss (n = 36/18%), ear fullness (n = 24/12%) and autophonia (n = 24/12%). Impedance were found in 100% of type A curves (Jerger, 1970), and recruitment was present in 20 (10%) cases. According to the results of audiometry, the data showed that 54 (27%) right ears and 56 (28%) left ears had hearing loss. The degree of loss with higher prevalence was 1 and 2 (Merluzzi et al., 1979), 85 (42.5%) cases. There was significant correlation between age and exposure time with the worsening of audiometric thresholds in both ears.
Conclusion: From the audiological data analysis was possible that the military police are a population that presents a risk to develop hearing loss. Thus, we see the need for implementation of hearing conservation program for the military police.
Resumo
Introdução: Os policiais militares constituem uma população exposta a ruído de impacto devido aos treinamentos com armas de fogo.
Objetivo: Pesquisar o perfil audiológico em policiais militares do estado de São Paulo, e correlacionar à idade e o tempo de exposição com os achados audiológicos.
Método: Neste estudo de série de casos, transversal, foi realizada avaliação audiológica em 200 policiais militares sendo 169 (84,5%) do gênero masculino e 31 (15,5%) do feminino, com idades entre 25 e 45 anos (média de 38,83 ± 5,05), com média de tempo de serviço de 16,80 ± 6,27 anos.
Resultados: As principais queixas apontadas foram: zumbido (n= 52 / 26%), disacusia (n = 36 / 18%), plenitude auricular (n = 24 / 12%) e autofonia (n = 24 / 12%). Na imitanciometria foram encontradas 100% de curvas tipo A (Jerger, 1970), e houve presença de recrutamento em 20 (10%) casos. Segundo os resultados da audiometria tonal, os dados obtidos demonstraram que 54 (27%) orelhas direita e 56 (28%) orelhas esquerda apresentaram perda auditiva. Os graus de perda com maior ocorrência foram 1 e 2 (Merluzzi et al., 1979), com 85 (42,5%) casos. Houve correlação significativa entre a idade e o tempo de exposição com a piora dos limiares audiométricos em ambas as orelhas.
Conclusão: A partir da análise dos dados audiológicos foi possível verificar que os policiais militares são uma população que apresenta risco para desenvolver a perda auditiva. Sendo assim, vemos a necessidade de implementação de programa de conservação auditiva para os policiais militares.
-
Bibliographic References
- 1 Jeger S, Jeger J. Alterações auditivas. Um manual para avaliação clínica. São Paulo: Atheneu; 1996. . p.133–38
- 2 Fiorini AC. Audição: impacto ambiental e ocupacional. . Em: Ferreira LP, Befi-Lopes DM, Limongi SCO. Tratado de fonoaudiologia. São Paulo: Roca; 2004. , p. 631–42
- 3 American College of Occupational and Enviromental Medicine; ACOEM Evidence-Based Statement. Noise-induced hearing loss. J Occup Environ Med 2003; 45 (6) 579-81
- 4 Ruggieri M, Cattan S, Giardini LDL, Oliveira KAS. Deficiência auditiva induzida por ruído em 472 trabalhadores da região do ABC paulista. Arq Méd ABC 1991; 14 (1) 19-23
- 5 Corrêa Filho HR, Costa LS, Hoehne EL, Pérez MG, Nascimento LCR, Moura EC. Perda auditiva induzida por ruído e hipertensão em condutores de ônibus. Rev Saúde Pública 2002; 36 (6) 693-701
- 6 Silva AP, Costa EA, Rodrigues SMMR, Souza HLR, Massafera VG. Avaliação do perfil auditivo de militares de um quartel do Exército Brasileiro. Rev Bras Otorrinolaringol 2004; 70 (3) 344-50
- 7 Araújo SA. Perda auditiva induzida pelo ruído em trabalhadores de matalúrgica. Rev Bras Otorrinolaringol 2002; 68 (1) 47-52
- 8 Lopes AC, Nelli MP, Lauris JRP, Amorim RB, Melo ADP. Condições de saúde auditiva no trabalho: investigação dos efeitos auditivos em trabalhadores expostos ao ruído ocupacional. Arq Int Otorrionlaringol 2009; 13 (1) 49-54
- 9 Guida HL, Kinoshita SK, Diniz TH. Análise acústica e psicoacústica do ruído de armas utilizadas pela polícia militar. Brazilian Journal of Otorhinolaryngology In press 2010.
- 10 Dias A, Cordeiro R, Corrente JE, Gonçalves CGO. Associação entre perda auditiva induzida pelo ruído e zumbidos. Cad Saúde Pública 2006; 22 (1) 63-8
- 11 Caldart AU, Adriano CF, Terruel I, Martins RF, Caldart AU, Mocellin M. Prevalência da perda auditiva induzida pelo ruído em trabalhadores de indústria têxtil. Arq Int Otorrinolaringol 2006; 10 (3) 192-196
- 12 Ylikoski ME, Ylikoski JS. Hearing loss and handicap of professional soldiers exposed to gunfire noise. Scand. J Work Environ 1994; 20: 93-100
- 13 Fundacentro. NHO 01: Norma de higiene ocupacional procedimento técnico - Avaliação da exposição ocupacional ao ruído. [citado 2007 out 31]. Disponível em: http://isegnet.com.br/arquivoscurso/atuais/anexo2.htm
- 14 Brasil. Portaria n° 3214. Ministério do Trabalho 08/07/1978; NR 15. Atividades e operações insalubres (D.O.U. 06/07/1978).
- 15 Neves BE, Mello MGS. O uso de dispositivos de proteção auditiva nos tiros de fuzil e artilharia. Cad Saúde Colet 2007; 15: 97-116
- 16 Ribeiro AMD, Câmara VM. Perda auditiva neurossensorial por exposição continuada a níveis elevados de pressão sonora em trabalhadores de manutenção de aeronaves de asas rotativas. Cad Saúde Pública 2006; 22: 1217-24
- 17 Gatto CI, Lemen RA, Teixeira TM, Magni C, Morata TC. A análise da conduta de médicos do trabalho diante de trabalhadores com perda auditiva. Rev Dist Com 2005; 17 (1) 101-115
- 18 Teo KJ, Chia SE, Tan CT, Ali SM. Effects of basic military training on hearing in the Singapore Armed Forces. Singapore Med 2008; 49: 243-47
- 19 Silva RCL, Zuba DCD. Perfil audiológico dos instrutores de tiro da polícia militar de Montes Claros - MG. Rev Consciência Extensão 2008; 1: 14-24
- 20 Lesage FX, Jovenin N, Deschamps F, Vincent S. Noise-induced hearing loss in French police officers. Occupational Medicine 2009; 3: 1-4
- 21 Sharif A, Taous A, Siddique BH, Dutta PG. Prevalence of noise induced hearing loss among traffic police in Dhaka Metropolitan City. Mymensingh Med J 2009; 18: 24-28
- 22 Polícia Militar do Estado de São Paulo. Secretaria do Estado dos Negócios de Segurança Pública. [citado em 2010 ago 27]. Disponível em: http://www.polmil.sp.gov.br/inicial.asp
- 23 Merluzzi F , et al. Metodologia di esecuzione del controllo dell'udito dei lavoratori esposti a rumore. Nuovo Arch Ital Otol 1979; 7: 695-714
- 24 Jerger J. Clinical experience with impedance audiometry. Arch Otolaryngol 1970; 92 (4) 311-24