CC BY 4.0 · Aorta (Stamford) 2013; 01(04): 227-230
DOI: 10.12945/j.aorta.2013.13-037
Case Report
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

A Single-Stage Repair of Arch and Descending Thoracic Aortic Aneurysms Using Jotec E-vita Open Plus Hybrid Stent Graft Combined With Antegrade Deployment of Thoracic Endograft

Mohamad Bashir
1   Thoracic Aortic Aneurysm Service, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
,
Matthew Fok
1   Thoracic Aortic Aneurysm Service, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
,
Richard G. McWilliams
3   Radiology Department, Royal Liverpool and Broadgreen University Hospitals, Liverpool, United Kingdom
,
Michael Desmond
2   Department of Anaesthesia, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
,
Mark Field
1   Thoracic Aortic Aneurysm Service, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
,
Robert K. Fisher
4   Department of Vascular Surgery, Royal Liverpool and Broadgreen University Hospitals, Liverpool, United Kingdom
,
Aung Oo
1   Thoracic Aortic Aneurysm Service, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
,
Manoj Kuduvalli
1   Thoracic Aortic Aneurysm Service, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
› Author Affiliations
Further Information

Publication History

02 August 2013

20 September 2013

Publication Date:
28 September 2018 (online)

Abstract

We report a unique case of a 63-year-old female with extensive peripheral vascular disease who underwent a single-stage surgical repair of the aortic arch and descending thoracic aortic aneurysm utilizing the Jotec E-vita Open Plus hybrid stent graft system combined with antegrade deployment of a thoracic endograft via a median sternotomy.

 
  • References

  • 1 Dake MD, Miller DC, Semba CP, Mitchell RS, Walker PJ, Liddell RP. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med 1994; 331: 1729-1734 . 10.1056/NEJM199412293312601
  • 2 Azizzadeh A, Estrera AL, Porat EE, Madsen KR, Safi HJ. The hybrid elephant trunk procedure: a single-stage repair of an ascending, arch, and descending thoracic aortic aneurysm. J Vasc Surg 2006; 44: 404-407 . 10.1016/j.jvs.2006.04.041
  • 3 Kourliouros A, Vecht J, Kakouros N, Grapsa J, Nihoyannopoulos P, Kokotsakis J. , et al. Frozen elephant trunk as an effective alternative to open and hybrid two-stage procedures for complex aortic disease. Hellenic J Cardiol 2011; 52: 337-344
  • 4 Lee CW, Beaver TM, Klodell Jr CT, Hess Jr PJ, Martin TD, Feezor RJ. , et al. Arch debranching versus elephant trunk procedures for hybrid repair of thoracic aortic pathologies. Ann Thorac Surg 2011; 91: 465-471 . 10.1016/j.athoracsur.2010.10.005