ABSTRACT

We describe a 44-year-old man with end-stage renal disease who underwent insertion of a stent graft to repair a hemodialysis graft pseudoaneurysm. The indication for stent graft placement was an acute and rapidly enlarging intragraft pseudoaneurysm. The patient experienced no complications following the procedure, but he presented with two graft occlusions within the 2 months following the procedure.

REFERENCES

  • 1 Vesely T M. Use of stent grafts to repair hemodialysis graft-related pseudoaneurysms.  J Vasc Interv Radiol. 2005;  16 1301-1307
  • 2 Hein A N, Vesely T M. Use of the percutaneous thrombolytic device for the treatment of thrombosed pseudoaneurysms during mechanical thrombectomy of hemodialysis grafts.  J Vasc Interv Radiol. 2002;  13 201-204
  • 3 Roy-Chaudhury P, Kelly B S, Melhem M et al.. Vascular access in hemodialysis: issues, management, and emerging concepts.  Cardiol Clin. 2005;  23 249-273
  • 4 Cinat M E, Hopkins J, Wilson S E. A prospective evaluation of PTFE graft patency and surveillance techniques in hemodialysis access.  Ann Vasc Surg. 1999;  13 191-198
  • 5 Ryan J M, Dumbleton S A, Doherty J, Smith T P. Technical innovation: using a covered stent (wallgraft) to treat pseudoaneurysms of dialysis grafts and fistulas.  AJR Am J Roentgenol. 2003;  180 1067-1071
  • 6 Silas A M, Bettmann M A. Utility of covered stents for revision of aging failing synthetic hemodialysis grafts: a report of three cases.  Cardiovasc Intervent Radiol. 2003;  26 550-553
  • 7 NKF-K/DOQI clinical practice guidelines for vascular access: update 2000.  Am J Kidney Dis. 2001;  37(suppl 1) S137-S181
  • 8 Rodriguez H E, Leon L, Schalch P, Labropoulos N, Borge M, Kalman P G. Arteriovenous access: managing common problems.  Perspect Vasc Surg Endovasc Ther. 2005;  17 155-166
  • 9 Rhodes E S, Silas A M. Dialysis needle puncture of Wallgrafts placed in polytetrafluoroethylene hemodialysis grafts.  J Vasc Interv Radiol. 2005;  16 1129-1134
  • 10 Najibi S, Bush R L, Terramani T T et al.. Covered stent exclusion of dialysis access pseudoaneurysms.  J Surg Res. 2002;  106 15-19
  • 11 Rabindranauth P, Shindelman L. Transluminal stent-graft repair for pseudoaneurysm of PTFE hemodialysis grafts.  J Endovasc Surg. 1998;  5 138-141
  • 12 Hausegger K A, Tiessenhausen K, Klimpfinger M, Raith J, Hauser H, Tauss J. Aneurysms of hemodialysis access grafts: treatment with covered stents-a report of three cases.  Cardiovasc Intervent Radiol. 1998;  21 334-337

Hector FerralM.D. 

Associate Professor of Radiology, Department of Radiology, Section of Interventional Radiology, Rush University Medical Center