RSS-Feed abonnieren
DOI: 10.1055/s-2003-42253
Placement of the Dumon Stent Using a Flexible Bronchofiberscope via Tracheostomy
Publikationsverlauf
Received February 10, 2003
Publikationsdatum:
19. September 2003 (online)
Abstract
In this paper, we report on a new technique of Dumon stent placement using a flexible bronchofiberscope. This procedure was used to insert Dumon stents in two bronchial obstruction and two bronchofistula cases. The stenting technique described here can be used through either a tracheostoma or the oral cavity; it presents a very straightforward and safe procedure that does not require the use of a rigid bronchoscope.
Key words
Technique - Dumon - stent - placement - flexible - bronchofiberscope - stenting
References
- 1 Colt H G, Dumon J F. Airway stents. Intervent Pulmonology. 1995; 16 465-478
- 2 Watanabe S, Shimokawa S, Yotsumoto G, Sakasegawa K. The use of a Dumon stent for the treatment of a bronchopleural fistula. Ann Thorac Surg. 2001; 72 276-278
- 3 Dumon J F. A dedicated tracheobronchial stent. Chest. 1990; 97 328-332
- 4 Watanabe S, Toyohira H, Yamaoka A, Yotsumoto G, Shiota K, Taira A. Usefulness of Dumon-type endotracheal stent for left main bronchial obstruction caused by thoracic aortic aneurysm: a case report (in Japanese with English abstract). Nippon Kyobu Geka Gakkai Zasshi. 1996; 44 1776-1780
- 5 Nomori H, Horio H, Suemasu K. Dumon stent placement via endotracheal tube. Chest. 1999; 115 582-583
Dr. S.-I. Watanabe
Second Department of Surgery, Kagoshima University Faculty of Medicine
8-35-1 Sakuragaoka
Kagoshima 890-8520
Japan
Telefon: + 81-99-275-5368
Fax: + 81-99-265-8177
eMail: shun@khosp2.kufm.kagoshima-u.ac.jp