CC BY-NC-ND 4.0 · Asian J Neurosurg
DOI: 10.1055/s-0044-1779421
Case Report

Balloon-Assisted Stent Visualization: A Simple Technique for Precise Measurement of Previously Placed Stent Diameter

1   Department of Neurosurgery, Saiseikai Shiga Hospital, Imperial Gift Foundation Inc., Ritto, Shiga, Japan
,
Shigeomi Yokoya
1   Department of Neurosurgery, Saiseikai Shiga Hospital, Imperial Gift Foundation Inc., Ritto, Shiga, Japan
,
Hidesato Takezawa
2   Department of Neurology, Saiseikai Shiga Hospital, Imperial Gift Foundation Inc., Ritto, Shiga, Japan
,
Midori Ichihashi
1   Department of Neurosurgery, Saiseikai Shiga Hospital, Imperial Gift Foundation Inc., Ritto, Shiga, Japan
,
Kengo Kishida
1   Department of Neurosurgery, Saiseikai Shiga Hospital, Imperial Gift Foundation Inc., Ritto, Shiga, Japan
,
Hideki Oka
1   Department of Neurosurgery, Saiseikai Shiga Hospital, Imperial Gift Foundation Inc., Ritto, Shiga, Japan
› Author Affiliations
Funding None.

Abstract

Stent-assisted coil embolization is effective for treating intracranial aneurysms, improving outcomes and reducing recurrence rates. However, accurately measuring the diameter of a previously placed stent during imaging can be challenging due to coil artifacts. This poses difficulties in determining the coil packing and size of additional stents needed during retreatment. In a reported case, the use of a balloon enabled precise assessment of stent deployment. A 50-year-old male with a history of basilar artery-left superior cerebellar artery aneurysm underwent coil embolization, direct clipping, and stent-assisted coil embolization (SAC) over a span of 14 years. However, the aneurysm showed reenlargement over time. To address the recurrence, a balloon was used to assess the previously placed Neuroform Atlas stent. Additional coils were inserted outside the stent, and a Low-profile Visualized Intraluminal Support Blue stent was added. Postoperatively, there were no new neurological issues, and a follow-up magnetic resonance imaging showed no ischemic lesions. Balloon-assisted stent visualization (BASV) may be a useful method in the retreatment of SAC. It has the potential to provide valuable information for treatment planning.

Ethical Approval Statement

This study was approved by the ethics committee of our hospital (Approval Number: 586).


Informed Consent

We obtained written informed consent from the patient for the publication of this case report and accompanying images.


Authors' Contributions

M.S, S.Y., and H.T. contributed to study conception and design. M.S. helped in data collection as well as analysis and interpretation of results. M.S., and S.Y., contributed to draft manuscript preparation. All authors (M.S., S.Y., H.T., M.I., K.K., H.O.) reviewed the results and approved the final version of manuscript.




Publication History

Article published online:
26 February 2024

© 2024. Asian Congress of Neurological Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Lynch J, Sciacca S, Siddiqui J, Kanagarajah L, Derakhshani S. Safety and efficacy of the Neuroform Atlas stent for treatment of intracranial aneurysms : a systematic review and meta-analysis. Clin Neuroradiol 2021; 31 (04) 1167-1180
  • 2 Mine B, Aljishi A, D'Harcour JB, Brisbois D, Collignon L, Lubicz B. Stent-assisted coiling of unruptured intracranial aneurysms: long-term follow-up in 164 patients with 183 aneurysms. J Neuroradiol 2014; 41 (05) 322-328
  • 3 Richter G, Engelhorn T, Struffert T. et al. Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms. AJNR Am J Neuroradiol 2007; 28 (10) 1902-1908
  • 4 van der Bom IMJ, Hou SY, Puri AS. et al. Reduction of coil mass artifacts in high-resolution flat detector conebeam CT of cerebral stent-assisted coiling. AJNR Am J Neuroradiol 2013; 34 (11) 2163-2170
  • 5 Patel NV, Gounis MJ, Wakhloo AK. et al. Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application. AJNR Am J Neuroradiol 2011; 32 (01) 137-144
  • 6 Liu XL, Wang B, Zhao LB, Jia ZY, Shi HB, Liu S. Overlapping stents-assisted coiling for vertebral artery dissecting aneurysm: LVIS stent within Neuroform EZ stent. J Korean Neurosurg Soc 2022; 65 (04) 523-530