CC BY 4.0 · Eur J Dent 2024; 18(02): 417-429
DOI: 10.1055/s-0043-1772249
Review Article

The Orthodontic Mini-Implants Failures Based on Patient Outcomes: Systematic Review

Siti Harlianti Putri Tarigan
1   Orthodontic Department, Faculty of Dentistry, Universitas Sumatera Utara, Medan, North Sumatera, Indonesia
,
1   Orthodontic Department, Faculty of Dentistry, Universitas Sumatera Utara, Medan, North Sumatera, Indonesia
,
1   Orthodontic Department, Faculty of Dentistry, Universitas Sumatera Utara, Medan, North Sumatera, Indonesia
› Author Affiliations

Abstract

Anchorage is a challenge and essential issue for an orthodontist in determining the success of orthodontic treatment. Orthodontic anchorage is defined as resistance to unwanted tooth movement. Mini-implant is one of the devices that can be used as an anchor in orthodontic treatment. Many cases have reported successful treatment using mini-implant, but there are cases where mini-implants may fail. Failure of mini-implants can affect orthodontic treatment, and it is known that several factors may lead to mini-implant loss in orthodontic treatment. This systematic review aimed to determine the factors influencing mini-implant failure in orthodontic treatment. Articles were selected from electronic databases (PubMed, Google Scholar, The Cochrane Library, ScienceDirect) from January 2015 until 2023 according to the PRISMA method (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) under the PEOS (Population-Exposure-Outcome-StudyType) framework questions for systematic review. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO) database (CRD42022337684). All data collected were in English, and filtering was done by eliminating duplicate data, meta-analysis, case reports, case series, mini-reviews, and animal studies. The analysis was further divided into three groups, that is, patient-related, implant-related, and operator-related and operator-related (A graphical abstract provided as a [Supplementary information] [available in the online version]). Twenty-one articles were identified according to the inclusion criteria in the form of retrospective, prospective, in vivo, and randomized controlled trial studies. Mini-implant failures due to patient-related showed six etiological factors, failures due to implant-related had eight etiological factors, and only one factor was operator-related, which may lead to mini-implant failure. The data was extracted without a computerized system and only in English. Mini-implant failure can be caused by many factors; we could not accuse one major factor as a cause. However, the quality or condition of the bones and oral hygiene are factors that play a significant role in obtaining the stability of implants. Mini-implant failure is highly influenced by poor oral hygiene and peri-implant inflammation. Comprehensive diagnostic prior to mini-implant insertion should be appropriately considered. This systematic review describes several factors that can influence mini-implant failure, divided into three groups: patient-related, implant-related, and operator-related (A graphical abstract provided as a [Supplementary information] [available in the online version]).

Supplementary Material



Publication History

Article published online:
17 October 2023

© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Kaul Y, Dhanani DCA. Temporary anchorage devices. Int Healthc Res J. 2017; 1 (03) 6-11
  • 2 Kuroda S, Tanaka E. Risks and complications of miniscrew anchorage in clinical orthodontics. Jpn Dent Sci Rev 2014; 50 (04) 79-85
  • 3 Elias CN, de Oliveira Ruellas AC, Fernandes DJ. Orthodontic implants: concepts for the orthodontic practitioner. Int J Dent 2012; 2012: 549761
  • 4 Papadopoulos MA, Tarawneh F. The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 103 (05) e6-e15
  • 5 Morais LS, Serra GG, Muller CA. et al. Titanium alloy mini-implants for orthodontic anchorage: immediate loading and metal ion release. Acta Biomater 2007; 3 (03) 331-339
  • 6 Safiya Sana SS. Mini-implant materials: an overview. IOSR J Dent Med Sci 2013; 7 (02) 15-20
  • 7 Huang LH, Shotwell JL, Wang HL. Dental implants for orthodontic anchorage. Am J Orthod Dentofacial Orthop 2005; 127 (06) 713-722
  • 8 Singh K, Kumar D, Jaiswal RK, Bansal A. Temporary anchorage devices - mini-implants. Natl J Maxillofac Surg 2010; 1 (01) 30-34
  • 9 Melo ACM, Andrighetto AR, Hirt SD, Bongiolo ALM, Silva SU, Silva MA. Risk factors associated with the failure of miniscrews - a ten-year cross sectional study. Braz Oral Res 2016; 30 (01) e124
  • 10 Antoszewska J, Papadopoulos MA, Park HS, Ludwig B. Five-year experience with orthodontic miniscrew implants: a retrospective investigation of factors influencing success rates. Am J Orthod Dentofacial Orthop 2009; 136 (02) 158.e1-158.e10 , discussion 158–159
  • 11 Sarul M, Minch L, Park HS, Antoszewska-Smith J. Effect of the length of orthodontic mini-screw implants on their long-term stability: a prospective study. Angle Orthod 2015; 85 (01) 33-38
  • 12 Azeem M, Haq AU, Awaisi ZH, Saleem MM, Tahir MW, Liaquat A. Failure rates of miniscrews inserted in the maxillary tuberosity. Dental Press J Orthod 2019; 24 (05) 46-51
  • 13 Kim J-W, Lee N-K, Sim H-Y, Yun P-Y, Lee J-H. Failure of orthodontic mini-implants by patient age, sex, and arch; number of primary insertions; and frequency of reinsertions after failure: an analysis of the implant failure rate and patient failure rate. Int J Periodont Restor Dent 2016; 36 (04) 559-565
  • 14 Rodrigues JMM, Santos PL, Mendonça G, Faloni APS, Finoti LS, Margonar R. Assessment of deviations of implants installed with prototyped surgical guide and conventional guide: in vitro study. Eur J Dent 2023; 17 (01) 39-45
  • 15 Hussain MW, Abullais SS, Naqash TA, Bhat MYS. Microbial etiology and antimicrobial therapy of peri-implantitis: a comprehensive review. Open Dent J 2019; 12 (01) 1113-1122
  • 16 Utami WS, Anggani HS, Purbiati M. Cytotoxicity effect of orthodontic miniscrew-implant in different types of mouthwash: an in-vitro study. J Orthod Sci 2022; 11 (01) 5
  • 17 Cortizo MC, Oberti TG, Cortizo MS, Cortizo AM, Fernández Lorenzo de Mele MA. Chlorhexidine delivery system from titanium/polybenzyl acrylate coating: evaluation of cytotoxicity and early bacterial adhesion. J Dent 2012; 40 (04) 329-337
  • 18 Nugraha AP, Ardani IGGW, Sitalaksmi RM. et al Anti-peri-implantitis bacteria's ability of Robusta green coffee bean (Coffea Canephora) ethanol extract: an in silico and in vitro study. Eur J Dent 2023; 17 (03) 649-662
  • 19 Uribe F, Mehr R, Mathur A, Janakiraman N, Allareddy V. Failure rates of mini-implants placed in the infrazygomatic region. Prog Orthod 2015; 16 (01) 31
  • 20 Papageorgiou SN, Zogakis IP, Papadopoulos MA. Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Am J Orthod Dentofacial Orthop 2012; 142 (05) 577-595.e7
  • 21 Joshi R, Shyagali TR, Jha R, Gupta A, Tiwari A, Tiwari T. Evaluation and comparison of the effect of elastomeric chain and stainless steel ligature wire on maxillary orthodontic miniscrew failure. Int J Appl Basic Med Res 2021; 11 (02) 100-105
  • 22 Aly SA, Alyan D, Fayed MS, Alhammadi MS, Mostafa YA. Success rates and factors associated with failure of temporary anchorage devices: a prospective clinical trial. J Investig Clin Dent 2018; 9 (03) e12331
  • 23 Munn Z, Barker TH, Moola S. et al. Methodological quality of case series studies: an introduction to the JBI critical appraisal tool. JBI Evid Synth 2020; 18 (10) 2127-2133
  • 24 Barker TH, Stone JC, Sears K. et al. The revised JBI critical appraisal tool for the assessment of risk of bias for randomized controlled trials. JBI Evid Synth 2023; 21 (03) 494-506
  • 25 Malik F, Khan F, Ali S, Rana F, Haq H, Hussain M. Factors affecting success and failure of orthodontic mini-implants: a retrospective review. Prof Med J 2023; 30 (02) 285-291
  • 26 Ikenaka R, Koizumi S, Otsuka T, Yamaguchi T. Effects of root contact length on the failure rate of anchor screw. J Oral Sci 2022; 64 (03) 232-235
  • 27 Schätzle M, Männchen R, Zwahlen M, Lang NP. Survival and failure rates of orthodontic temporary anchorage devices: a systematic review. Clin Oral Implants Res 2009; 20 (12) 1351-1359
  • 28 Crismani AG, Bertl MH, Čelar AG, Bantleon HP, Burstone CJ. Miniscrews in orthodontic treatment: review and analysis of published clinical trials. Am J Orthod Dentofacial Orthop 2010; 137 (01) 108-113
  • 29 Dalessandri D, Salgarello S, Dalessandri M. et al. Determinants for success rates of temporary anchorage devices in orthodontics: a meta-analysis (n > 50). Eur J Orthod 2014; 36 (03) 303-313
  • 30 Sreenivasagan S, Subramanian AK, Rengalakshmi S. Prevalence and cause of mini-implant failure encountered by orthodontic residents. J Long Term Eff Med Implants 2021; 31 (04) 1-4
  • 31 Baik U-B, Bayome M, Han K-H, Park JH, Jung M-H, Kook Y-A. Evaluation of factors affecting the success rate of orthodontic mini-implants by survival analysis. World J Stomatol. 2013; 2 (03) 56-61
  • 32 Rasool G, Mahmood Shah A, Rahman S, Hussain U, Saeed A, Gul P. Success rate of different insertion sites and lengths of success rate of different insertion sites and lengths of mini screws in orthodontic patients. JKCD 2018; 8 (01) 49-53
  • 33 Maki K, Miller A, Okano T, Shibasaki Y. Changes in cortical bone mineralization in the developing mandible: a three-dimensional quantitative computed tomography study. J Bone Miner Res 2000; 15 (04) 700-709
  • 34 Arqub SA, Gandhi V, Mehta S, Palo L, Upadhyay M, Yadav S. Survival estimates and risk factors for failure of palatal and buccal mini-implants. Angle Orthod 2021; 91 (06) 756-763
  • 35 Yoshida M, Nakano H, Haga S, Arishima T, Maki K. Investigation of the association between vertical skeletal patterns and the timing of failure of temporary anchorage devices. Showa Univ J Med Sci 2022; 34 (04) 191-199
  • 36 Xin Y, Wu Y, Chen C, Wang C, Zhao L. Miniscrews for orthodontic anchorage: analysis of risk factors correlated with the progressive susceptibility to failure. Am J Orthod Dentofacial Orthop 2022; 162 (04) e192-e202
  • 37 Lee SJ, Ahn SJ, Lee JW, Kim SH, Kim TW. Survival analysis of orthodontic mini-implants. Am J Orthod Dentofacial Orthop 2010; 137 (02) 194-199
  • 38 Fayed MM, Pazera P, Katsaros C. Optimal sites for orthodontic mini-implant placement assessed by cone beam computed tomography. Angle Orthod 2010; 80 (05) 939-951
  • 39 Farnsworth D, Rossouw PE, Ceen RF, Buschang PH. Cortical bone thickness at common miniscrew implant placement sites. Am J Orthod Dentofacial Orthop 2011; 139 (04) 495-503
  • 40 Chen YJ, Chang HH, Huang CY, Hung HC, Lai EHH, Yao CCJ. A retrospective analysis of the failure rate of three different orthodontic skeletal anchorage systems. Clin Oral Implants Res 2007; 18 (06) 768-775
  • 41 Präger TM, Brochhagen HG, Mischkowski R, Jost-Brinkmann PG, Müller-Hartwich R. Bone condition of the maxillary zygomatic process prior to orthodontic anchorage plate fixation. J Orofac Orthop 2015; 76 (01) 3-13
  • 42 Gill G, Shashidhar K, Kuttappa MN, Kushalappa P B D, Sivamurthy G, Mallick S. Failure rates and factors associated with infrazygomatic crestal orthodontic implants - a prospective study. J Oral Biol Craniofac Res 2023; 13 (02) 283-289
  • 43 Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, Takano-Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 2003; 124 (04) 373-378
  • 44 Wu TY, Kuang SH, Wu CH. Factors associated with the stability of mini-implants for orthodontic anchorage: a study of 414 samples in Taiwan. J Oral Maxillofac Surg 2009; 67 (08) 1595-1599
  • 45 Sharma P, Valiathan A, Sivakumar A. Success rate of microimplants in a university orthodontic clinic. ISRN Surg 2011; 2011: 982671
  • 46 Park HS, Jeong SH, Kwon OW. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2006; 130 (01) 18-25
  • 47 Rosier BT, Marsh PD, Mira A. Resilience of the oral microbiota in health: mechanisms that prevent dysbiosis. J Dent Res 2018; 97 (04) 371-380
  • 48 Zhao N, Zhang Q, Guo Y. et al. Oral microbiome contributes to the failure of orthodontic temporary anchorage devices (TADs). BMC Oral Health 2023; 23 (01) 22
  • 49 Belibasakis GN, Manoil D. Microbial community-driven etiopathogenesis of peri-implantitis. J Dent Res 2021; 100 (01) 21-28
  • 50 Zhang Y, Li Y, Yang Y. et al. Periodontal and peri-implant microbiome dysbiosis is associated with alterations in the microbial community structure and local stability. Front Microbiol 2022; 12: 785191
  • 51 Mote N, Rajbhar J, Toshniwal NG, Rathod R. To evaluate success and failure rate of temporary anchorage devices (TADS) in various attachments sites in maxilla abstract. Egypt Orthod J 2022; 61 (06) 60-71
  • 52 Kim HJ, Yun HS, Park HD, Kim DH, Park YC. Soft-tissue and cortical-bone thickness at orthodontic implant sites. Am J Orthod Dentofacial Orthop 2006; 130 (02) 177-182
  • 53 Ntolou P, Tagkli A, Pepelassi E. Factors related to the clinical application of orthodontic mini-implants. J Int Oral Health 2018; 10 (03) 103-110
  • 54 Durrani OK. Comparison of in vivo failure of precipitation-coated hydroxyapatite temporary anchorage devices with that of uncoated temporary anchorage devices over 18 months. Am J Orthod Dentofacial Orthop 2023; 163 (04) 520-525
  • 55 Wiechmann D, Meyer U, Büchter A. Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study. Clin Oral Implants Res 2007; 18 (02) 263-267
  • 56 Ono A, Motoyoshi M, Shimizu N. Cortical bone thickness in the buccal posterior region for orthodontic mini-implants. Int J Oral Maxillofac Surg 2008; 37 (04) 334-340
  • 57 Baumgaertel S, Hans MG. Buccal cortical bone thickness for mini-implant placement. Am J Orthod Dentofacial Orthop 2009; 136 (02) 230-235
  • 58 Trisi P, Rebaudi A. Peri-implant bone reaction to immediate, early, and delayed orthodontic loading in humans. Int J Periodontics Restorative Dent 2005; 25 (04) 317-329
  • 59 Chen YJ, Chang HH, Lin HY, Lai EHH, Hung HC, Yao CCJ. Stability of miniplates and miniscrews used for orthodontic anchorage: experience with 492 temporary anchorage devices. Clin Oral Implants Res 2008; 19 (11) 1188-1196
  • 60 Nkenke E, Lehner B, Weinzierl K. et al. Bone contact, growth, and density around immediately loaded implants in the mandible of mini pigs. Clin Oral Implants Res 2003; 14 (03) 312-321
  • 61 Chang CH, Lin JS, Roberts WE. Failure rates for stainless steel versus titanium alloy infrazygomatic crest bone screws: a single-center, randomized double-blind clinical trial. Angle Orthod 2019; 89 (01) 40-46
  • 62 Farronato D, Mangano F, Briguglio F, Iorio-Siciliano V, Riccitiello F, Guarnieri R. Influence of Laser-Lok surface on immediate functional loading of implants in single-tooth replacement: a 2-year prospective clinical study. Int J Periodont Restor Dent 2014; 34 (01) 79-89
  • 63 Guarnieri R, Grande M, Ippoliti S, Iorio-Siciliano V, Riccitiello F, Farronato D. Influence of a laser-Lok surface on immediate functional loading of implants in single-tooth replacement: three-year results of a prospective randomized clinical study on soft tissue response and esthetics. Int J Periodont Restor Dent 2015; 35 (06) 865-875
  • 64 Kim JE, Kang SS, Choi KH. et al. The effect of anodized implants coated with combined rhBMP-2 and recombinant human vascular endothelial growth factors on vertical bone regeneration in the marginal portion of the peri-implant. Oral Surg Oral Med Oral Pathol Oral Radiol 2013; 115 (06) e24-e31
  • 65 Chang C, Liu SSY, Roberts WE. Primary failure rate for 1680 extra-alveolar mandibular buccal shelf mini-screws placed in movable mucosa or attached gingiva. Angle Orthod 2015; 85 (06) 905-910
  • 66 Kingsmill VJ, Boyde A. Variation in the apparent density of human mandibular bone with age and dental status. J Anat 1998; 192 (Pt 2): 233-244
  • 67 Han S, Bayome M, Lee J, Lee YJ, Song HH, Kook YA. Evaluation of palatal bone density in adults and adolescents for application of skeletal anchorage devices. Angle Orthod 2012; 82 (04) 625-631
  • 68 Du X, Jiao J, Cheng X. et al. Age-related changes of bone mineral density in mandible by quantitative computed tomography. J Biol Regul Homeost Agents 2017; 31 (04) 997-1003
  • 69 Azeem M, Saleem MM, Liaquat A, Ul Haq A, Ul Hamid W, Masood M. Failure rates of mini-implants inserted in the retromolar area. Int Orthod 2019; 17 (01) 53-59
  • 70 Ichinohe M, Motoyoshi M, Inaba M. et al. Risk factors for failure of orthodontic mini-screws placed in the median palate. J Oral Sci 2019; 61 (01) 13-18
  • 71 Uesugi S, Kokai S, Kanno Z, Ono T. Stability of secondarily inserted orthodontic miniscrews after failure of the primary insertion for maxillary anchorage: maxillary buccal area vs midpalatal suture area. Am J Orthod Dentofacial Orthop 2018; 153 (01) 54-60
  • 72 Durrani OK, Shaheed S, Khan A, Bashir U. Comparison of in-vivo failure of single-thread and dual-thread temporary anchorage devices over 18 months: a split-mouth randomized controlled trial. Am J Orthod Dentofacial Orthop 2017; 152 (04) 451-457
  • 73 Jeong J-W, Kim J-W, Lee N-K, Kim Y-K, Lee J-H, Kim T-W. Analysis of time to failure of orthodontic mini-implants after insertion or loading. J Korean Assoc Oral Maxillofac Surg 2015; 41 (05) 240-245