Vet Comp Orthop Traumatol 2024; 37(01): 050-056
DOI: 10.1055/s-0043-1771190
Clinical Communication

Use of Locking Plates Fixed with Cortical Screws for Pelvic Fracture Repair in 20 Cats

1   Christchurch Veterinary Referrals, Ipswich, United Kingdom
,
2   The Ralph Veterinary Referral Centre, Marlow, United Kingdom
,
Shane Morrison
3   Advanced Practitioner in Small Animal Surgery - Christchurch Veterinary Referrals, Ipswich, United Kingdom
,
Richard Whitelock
4   Grove Referrals, Fakenham, United Kingdom
› Author Affiliations

Abstract

Objective The aim of this study is to describe the use of String of Pearls (SOP) plates for the surgical management of feline pelvic fractures, including surgical technique, proposed indications, complications, and outcomes in a cohort of cats.

Study Design This study is a single-center retrospective clinical case series.

Methods Medical records (2015–2019) of cats presenting for pelvic fractures (n = 33) were reviewed. Type of fracture, preoperative and postoperative imaging, and complications were retrospectively retrieved. Owners were contacted via questionnaire for medium- and long-term follow-up.

Results A total of 20 cats met the inclusion criteria. Minor intraoperative complications were encountered in three patients. One patient suffered a major intraoperative complication. Five major complications were encountered postoperatively. These included two greater trochanter osteotomy fixation implant removal and three SOP plate removal. Full function was recovered in all patients according to the owners' assessment.

Clinical Significance The use of SOP plates in feline pelvic fractures appears to yield a consistently good outcome with a very low incidence of canal narrowing and screw loosening. SOP plates are easy to contour and to apply along the entire pelvic length.

Authors' Contribution

E.A.D., S.G., S.M., R.W. contributed to the conception, study design, acquisition of data, data analysis and interpretation. All authors drafted, revised, and approved the submitted manuscript and are publicly responsible for the relevant content.


Supplementary Material



Publication History

Received: 12 September 2022

Accepted: 09 June 2023

Article published online:
11 September 2023

© 2023. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Hill FW. A survey of bone fractures in the cat. J Small Anim Pract 1977; 18 (07) 457-463
  • 2 Meeson R, Corr S. Management of pelvic trauma: neurological damage, urinary tract disruption and pelvic fractures. J Feline Med Surg 2011; 13 (05) 347-361
  • 3 Bennett D. Orthopaedic disease affecting the pelvic region of the cat. J Small Anim Pract 1975; 16 (11) 723-738
  • 4 Hamilton MH, Evans DA, Langley-Hobbs SJ. Feline ilial fractures: assessment of screw loosening and pelvic canal narrowing after lateral plating. Vet Surg 2009; 38 (03) 326-333
  • 5 Langley-Hobbs SJ, Meeson RL, Hamilton MH, Radke H, Lee K. Feline ilial fractures: a prospective study of dorsal plating and comparison with lateral plating. Vet Surg 2009; 38 (03) 334-342
  • 6 Bush M. The pelvis and sacroiliac joint. In: BSAVA Manual of Canine and Feline Fracture Repair and Management. Gloucestershire, UK: British Small Animal Veterinary Association; 2016
  • 7 Wiersema T, Koolen T, Theyse LFH, Maarschalkweerd RJ, van Zuilen CD, van Rijn SJ. Comparison of single versus double lateral plating in treatment of feline ilial fractures using veterinary cuttable plates. Vet Comp Orthop Traumatol 2021; 34 (05) 321-326
  • 8 Scrimgeour AB, Craig A, Witte PG. Locking T-plate repair of ilial fractures in cats and small dogs. Vet Comp Orthop Traumatol 2017; 30 (06) 453-460
  • 9 Chou P, Runyon C, Bailey T, Béraud R. Use of Y-shaped TPLO plates for the stabilization of supracotyloid ilial fractures in four dogs and one cat. Vet Comp Orthop Traumatol 2013; 26 (03) 226-232
  • 10 Guthrie JW, Kalff S. Tibial plateau levelling osteotomy locking-compression plates for stabilisation of canine and feline ilial body fractures. J Small Anim Pract 2018; 59 (04) 232-237
  • 11 Schmierer PA, Smolders LA, Zderic I, Gueorguiev B, Pozzi A, Knell SC. Biomechanical properties of plate constructs for feline ilial fracture gap stabilization. Vet Surg 2019; 48 (01) 88-95
  • 12 Langley-Hobbs SJ, Sissener TR, Shales CJ. Tension band stabilisation of acetabular physeal fractures in four kittens. J Feline Med Surg 2007; 9 (03) 177-187
  • 13 Krebs RC, Roe SC, Lascelles BD, Marcellin-Little DJ, Trumpatori BJ, Spodnick G. Biomechanical evaluation of the influence of an intramedullary pin on the stability of a feline ilial fracture model stabilized with a bone plate. Vet Surg 2014; 43 (02) 114-119
  • 14 Schmierer PA, Kircher PR, Hartnack S, Knell SC. Screw loosening and pelvic canal narrowing after lateral plating of feline ilial fractures with locking and nonlocking plates. Vet Surg 2015; 44 (07) 900-904
  • 15 Troger JC, Viguier E. Use of T-plates for the stabilisation of supra-cotyloid ilial fractures in 18 cats and five dogs. Vet Comp Orthop Traumatol 2008; 21 (01) 69-75
  • 16 Meeson RL, Geddes AT. Management and long-term outcome of pelvic fractures: a retrospective study of 43 cats. J Feline Med Surg 2017; 19 (01) 36-41
  • 17 Vangundy TE, Hulse DA, Nelson JK, Boothe HW. Mechanical evaluation of two canine iliac fracture fixation systems. Vet Surg 1988; 17 (06) 321-327
  • 18 Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ. Biomechanics of locked plates and screws. J Orthop Trauma 2004; 18 (08) 488-493
  • 19 Gautier E, Perren SM, Cordey J. Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis. Injury 2000; 31 (Suppl. 03) C14-C20
  • 20 Bruce CW, Gibson TW, Runciman RJ. A comparison of conventional compression plates and locking compression plates using cantilever bending in an ilial fracture model. Vet Comp Orthop Traumatol 2014; 27 (06) 430-435
  • 21 Wagner M. General principles for the clinical use of the LCP. Injury 2003; 34 (Suppl. 02) B31-B42
  • 22 Kraus KH, Ness MG, Rutherford S. Standard Operating for SOP Interlocking Plate System. Huddersfield, UK: Orthomed; 2016
  • 23 Sadan MA, Fischer A, Bokemeyer J, Kramer M. Surgical repair of ilial fractures in dogs and cats using string of pearls (SOP)-plate. Indian J Vet Surg 2015; 36: 41-45
  • 24 Johnson KA. Piermattei's Atlas of Surgical Approaches to the Bones and Joints of the Dog and Cat. 5th ed. St. Louis, MO: Elsevier/Saunders; 2014
  • 25 Breshears LA, Fitch RB, Wallace LJ, Wells CS, Swiderski JK. The radiographic evaluation of repaired canine ilial fractures (69 cases). VCOT 2004; 17: 64-72
  • 26 Cook JL, Evans R, Conzemius MG. et al. Proposed definitions and criteria for reporting time frame, outcome, and complications for clinical orthopedic studies in veterinary medicine. Vet Surg 2010; 39 (08) 905-908
  • 27 Bogoni P, Rovesti GL. Early detection and treatment of screw loosening in triple pelvic osteotomy. Vet Surg 2005; 34 (03) 190-195
  • 28 Boero Baroncelli A, Reif U, Bignardi C, Peirone B. Effect of screw insertion torque on push-out and cantilever bending properties of five different angle-stable systems. Vet Surg 2013; 42 (03) 308-315
  • 29 Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury 2003; 34 (Suppl. 02) B63-B76
  • 30 Moores A. . Kowaleski, Piras, et al. Advances in Fracture Management – BVOA Spring Scientific Meeting 2009. In: Moores A. ed. Advances in Fracture Management. Devon, UK: British Veterinary Orthopaedic Association; 2009
  • 31 Decamp CE, Braden TD. Sacroiliac fracture-separation in the dog: a study of 92 cases. Vet Surg 1985; 14 (02) 127-130
  • 32 Whitelock RG, Dyce J, Houlton JE. Repair of femoral trochanteric osteotomy in the dog. J Small Anim Pract 1997; 38 (05) 195-199