Vet Comp Orthop Traumatol 2023; 36(06): 273-278
DOI: 10.1055/s-0043-1768990
Original Research

Effects of Transfixation Pin Positioning on the Biomechanical Properties of Acrylic External Skeletal Fixators in a Fracture Gap Model

1   Faculty of Veterinary Medicine, University of Montreal, Saint Hyacinthe, Québec, Canada
,
Mila Freire
1   Faculty of Veterinary Medicine, University of Montreal, Saint Hyacinthe, Québec, Canada
,
Xavier Montasell
2   Centre Vétérinaire Daubigny, Québec, Canada
,
Tristan Juette
1   Faculty of Veterinary Medicine, University of Montreal, Saint Hyacinthe, Québec, Canada
,
Dominique Gagnon
1   Faculty of Veterinary Medicine, University of Montreal, Saint Hyacinthe, Québec, Canada
› Institutsangaben
Funding The study has been funded by the Fonds du Centenaire and the Fonds en santé des animaux de compagnie of the Faculty of Veterinary Medicine of the University of Montreal, supported by Zoetis.

Abstract

Objective The aim of this study was to evaluate the biomechanical effects of transfixation pin positioning in acrylic columns of external skeletal fixators (ESF).

Study Design Twenty-four type I acrylic ESF were built simulating a fracture gap-model. Transfixation pins were placed centric (n = 12) or eccentric at ¼ of the column diameter (n = 12) in the acrylic columns. Six constructs from each group were subjected to axial compression and four-point bending tests. Stiffness, yield load and mode of failure were recorded.

Results Stiffness was not influenced by centring (p = 0.373), but it was higher in four-point bending than in axial compression (p < 0.001). Pin positioning had no influence on the yield (p = 0.535) and failure loads (p = 0.715) in axial compression, nor on the yield load in bending (p = 0.135). Eccentric pin positioning decreased failure loads by 28% in bending (p < 0.001).

Conclusion Eccentric position of transfixation pins within the acrylic columns alters the biomechanical properties of type I ESF constructs. While acrylic offers several advantages, when forming the columns, frame strength will be optimized if pins are centrally located.

Notes

This work was submitted in abstract form and accepted for oral presentation in the Resident's Forum at the American College of Veterinary Surgeons (ACVS) Surgery Summit, Portland, United States, October 2022.


Authors' Contribution

All authors conceptualized and designed the study. J.L. and D.G. acquired the data. All authors did data analysis and interpretation of the results, as well as drafted, revised and approved the submitted manuscript and are publicly responsible for the relevant content.




Publikationsverlauf

Eingereicht: 12. August 2022

Angenommen: 22. April 2023

Artikel online veröffentlicht:
19. Juni 2023

© 2023. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Brad Case J, Egger EL. Evaluation of strength at the acrylic-pin interface for variably treated external skeletal fixator pins. Vet Surg 2011; 40 (02) 211-215
  • 2 Egger EL. Static strength evaluation of six external skeletal fixation configurations. Vet Surg 1983; 12 (03) 130-136
  • 3 Lewis DD, Cross AR, Carmichael S, Anderson MA. Recent advances in external skeletal fixation. J Small Anim Pract 2001; 42 (03) 103-112
  • 4 Ross JT, Matthiesen DT. The use of multiple pin and methylmethacrylate external skeletal fixation for the treatment of orthopaedic injuries in the dog and cat. Vet Comp Orthop Traumatol 1993; 06 (02) 115-121
  • 5 Herndon GD, Egger EL. The effect of contouring the connecting bar in an acrylic-pin external fixator. Vet Comp Orthop Traumatol 2001; 14 (04) 190-195
  • 6 Leriquier C, Audet-Robin F, Beauchamp G, Montasell X. Effects of the number and the position of transfixation pins in acrylic connecting bars. Can J Vet Res 2022; 86 (01) 35-39
  • 7 Montasell X, Herndon G, Szwec D, Beauchamp G. The effect of transfixation pins on the biomechanical properties of angled acrylic connecting bars. Can J Vet Res 2019; 83 (01) 17-23
  • 8 Tyagi SK, Aithal HP, Kinjavdekar P. et al. In vitro biomechanical testing of different configurations of acrylic external skeletal fixator constructs. Vet Comp Orthop Traumatol 2015; 28 (04) 227-233
  • 9 Hersh-Boyle RA, Kapatkin AS, Garcia TC. et al. Comparison of torsional properties between a Fixateur Externe du Service de Santé des Armées and an acrylic tie-in external skeletal fixator in a red-tailed hawk (Buteo jamaicensis) synthetic tibiotarsal bone model. Am J Vet Res 2020; 81 (07) 557-564
  • 10 Huber D, Egger E, James S. A mechanical comparison of the fixation pin-connecting bar junction of Kirschner-Ehmer and acrylic external fixators. Vet Surg 1998; 27 (05) 498-523
  • 11 Okrasinski EB, Pardo AD, Graehler RA. Biomechanical evaluation of acrylic external skeletal fixation in dogs and cats. J Am Vet Med Assoc 1991; 199 (11) 1590-1593
  • 12 ASTM F1541–17. Standard Specification and Test Methods for External Skeletal Fixation Devices. Accessed April 30, 2023 at: https://www.astm.org/f1541-17.html
  • 13 R Core Team. . (2020). R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. Accessed April 30, 2023 at: http://www.R-project.org/
  • 14 Amsellem PM, Egger EL, Wilson DL. Bending characteristics of polymethylmethacrylate columns, connecting bars of carbon fiber, titanium, and stainless steel used in external skeletal fixation and an acrylic interface. Vet Surg 2010; 39 (05) 631-637
  • 15 Shahar R. Relative stiffness and stress of type I and type II external fixators: acrylic versus stainless-steel connecting bars–a theoretical approach. Vet Surg 2000; 29 (01) 59-69
  • 16 Shahar R. Evaluation of stiffness and stress of external fixators with curved acrylic connecting bars. Vet Comp Orthop Traumatol 2000; 13 (02) 65-72
  • 17 Owen M, Hobbs S, Moores A. et al. Mandibular fracture repair in dogs and cats using epoxy resin and acrylic external skeletal fixation. Vet Comp Orthop Traumatol 2004; 17 (04) 189-197
  • 18 Kraus K, Tombs J, Ness M. Basics of external fixation. In: Kraus K, Tombs J, Ness M. eds. External Fixation in Small Animal Practice. Oxford: Blackwell Science; 2003: 5-12
  • 19 Jaeger G, Wosar M. External skeletal fixation. In: Veterinary Surgery: Small Animal. Vol 1. 2nd ed. Amsterdam: Elsevier; 2018: 691-720
  • 20 Anderson MA, Mann FA, Wagner-Mann C, Hahn AW, Jiang BL, Tomlinson JL. A comparison of nonthreaded, enhanced threaded, and Ellis fixation pins used in type I external skeletal fixators in dogs. Vet Surg 1993; 22 (06) 482-489
  • 21 Bennett RA, Egger EL, Histand M, Ellis AB. Comparison of the strength and holding power of 4 pin designs for use with half pin (type I) external skeletal fixation. Vet Surg 1987; 16 (03) 207-211
  • 22 Clary EM, Roe SC. Enhancing external skeletal fixation pin performance: consideration of the pin-bone interface. Vet Comp Orthop Traumatol 1995; 08 (01) 6-13
  • 23 Cross AR, Lewis DD, Rigaud S, Rapoff AJ. Effect of various distal ring-block configurations on the biomechanical properties of circular external skeletal fixators for use in dogs and cats. Am J Vet Res 2004; 65 (04) 393-398
  • 24 White DT, Bronson DG, Welch RD. A mechanical comparison of veterinary linear external fixation systems. Vet Surg 2003; 32 (06) 507-514
  • 25 Burton NJ, Fitzpatrick N, Wallace AM. Evaluation of cut accuracy and cis cortical damage for tibial plateau leveling osteotomy performed with and without aid of a novel saw guide: an in vitro study. Vet Surg 2013; 42 (01) 28-37
  • 26 Hausmann JT. Sawbones in biomechanical settings - a review. Osteosynth Trauma Care 2006; 14 (04) 259-264