CC BY-NC-ND 4.0 · Journal of Clinical Interventional Radiology ISVIR 2023; 07(03): 172-178
DOI: 10.1055/s-0043-1768040
Original Article

Safety and Efficacy of Vacuum-Assisted Breast Biopsies under Ultrasound and Stereotactic Guidance

Palak Bhavesh Thakkar Popat
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Aashna Karbhari
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Nitin Shetty
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Kunal Gala
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Purvi Haria
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Aparna Katdare
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Sonal Chauhan
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Vani Parmar
2   Department of Surgical Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Nita Nair
2   Department of Surgical Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Shalaka Joshi
2   Department of Surgical Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Sangeeta Desai
3   Department of Pathology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Tanuja Shet
3   Department of Pathology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Asawari Patil
3   Department of Pathology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Ayushi Sahay
3   Department of Pathology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Meenakshi Thakur
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Rajendra Badwe
4   Department of Surgical Oncology, Tata Memorial Centre, Homi Bhabha National Institute, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Suyash Kulkarni
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
› Author Affiliations
Funding None.

Abstract

Purpose To evaluate the safety and efficacy of vacuum-assisted breast biopsy (VABB) under ultrasound and stereotactic guidance.

Methods This institutionally approved retrospective analysis comprised 60 females who underwent VABB under ultrasound and stereotactic guidance. Technical success and adverse events were analyzed as per the Society of Interventional Radiology standards. Pain score was recorded as per the visual analog scale.

Results Technical success was 100% with high specificity (100%), sensitivity (96%), negative predictive value 97%, and accuracy of 98%. Ductal carcinoma in situ underestimation rate was 4%. No major complications were encountered, and minor complication of postprocedural hematoma did not require intervention. Procedure was well tolerated with majority patients experiencing mild pain.

Conclusion VABB under ultrasound and stereotactic guidance is a safe and effective method for sampling breast abnormalities.

Ethical Approval

This was an ethics approved study for analysis but being retrospective, formal consent was not required.




Publication History

Article published online:
12 June 2023

© 2023. Indian Society of Vascular and Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Sung H, Ferlay J, Siegel RL. et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 2021; 71 (03) 209-249
  • 2 Parker SH, Jobe WE, Dennis MA. et al. US-guided automated large-core breast biopsy. Radiology 1993; 187 (02) 507-511
  • 3 Liberman L, Feng TL, Dershaw DD, Morris EA, Abramson AF. US-guided core breast biopsy: use and cost-effectiveness. Radiology 1998; 208 (03) 717-723
  • 4 Smith DN, Rosenfield Darling ML, Meyer JE. et al. The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies. J Ultrasound Med 2001; 20 (01) 43-49
  • 5 Fishman JE, Milikowski C, Ramsinghani R, Velasquez MV, Aviram G. US-guided core-needle biopsy of the breast: how many specimens are necessary?. Radiology 2003; 226 (03) 779-782
  • 6 Fajardo LL, Pisano ED, Caudry DJ. et al; Radiologist Investigators of the Radiologic Diagnostic Oncology Group V. Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study. Acad Radiol 2004; 11 (03) 293-308
  • 7 Jackman RJ, Nowels KW, Rodriguez-Soto J, Marzoni Jr FA, Finkelstein SI, Shepard MJ. Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up. Radiology 1999; 210 (03) 799-805
  • 8 Darling ML, Smith DN, Lester SC. et al. Atypical ductal hyperplasia and ductal carcinoma in situ as revealed by large-core needle breast biopsy: results of surgical excision. AJR Am J Roentgenol 2000; 175 (05) 1341-1346
  • 9 Han BK, Choe YH, Ko YH, Nam SJ, Kim JH, Yang JH. Stereotactic core-needle biopsy of non-mass calcifications: outcome and accuracy at long-term follow-up. Korean J Radiol 2003; 4 (04) 217-223
  • 10 Burbank F, Parker SH, Fogarty TJ. Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg 1996; 62 (09) 738-744
  • 11 Berg WA, Krebs TL, Campassi C, Magder LS, Sun CC. Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model. Radiology 1997; 205 (01) 203-208
  • 12 Parker SH, Klaus AJ, McWey PJ. et al. Sonographically guided directional vacuum-assisted breast biopsy using a handheld device. AJR Am J Roentgenol 2001; 177 (02) 405-408
  • 13 Yu YH, Liang C, Yuan XZ. Diagnostic value of vacuum-assisted breast biopsy for breast carcinoma: a meta-analysis and systematic review. Breast Cancer Res Treat 2010; 120 (02) 469-479
  • 14 Penco S, Rizzo S, Bozzini AC. et al. Stereotactic vacuum-assisted breast biopsy is not a therapeutic procedure even when all mammographically found calcifications are removed: analysis of 4,086 procedures. AJR Am J Roentgenol 2010; 195 (05) 1255-1260
  • 15 Kettritz U, Rotter K, Schreer I. et al. Stereotactic vacuum-assisted breast biopsy in 2874 patients: a multicenter study. Cancer 2004; 100 (02) 245-251
  • 16 Tsai HY, Chao MF, Ou-Yang F. et al. Accuracy and outcomes of stereotactic vacuum-assisted breast biopsy for diagnosis and management of nonpalpable breast lesions. Kaohsiung J Med Sci 2019; 35 (10) 640-645
  • 17 Fu SM, Wang XM, Yin CY, Song H. Effectiveness of hemostasis with Foley catheter after vacuum-assisted breast biopsy. J Thorac Dis 2015; 7 (07) 1213-1220
  • 18 Reporting BI. Data System (BI-RADS). Reston (VA): American College of Radiology; 1998
  • 19 Khalilzadeh O, Baerlocher MO, Shyn PB. et al. Proposal of a new adverse event classification by the Society of Interventional Radiology Standards of Practice Committee. J Vasc Interv Radiol 2017; 28 (10) 1432-1437 .e3
  • 20 Sheth RA, Baerlocher MO, Connolly BL. et al. Society of Interventional Radiology quality improvement standards on percutaneous needle biopsy in adult and pediatric patients. Journal of vascular and interventional radiology. J Vasc Interv Radiol 2020; 31 (11) 1840-1848
  • 21 Cassano E, Urban LA, Pizzamiglio M. et al. Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases. Breast Cancer Res Treat 2007; 102 (01) 103-110
  • 22 Suh YJ, Kim MJ, Kim EK. et al. Comparison of the underestimation rate in cases with ductal carcinoma in situ at ultrasound-guided core biopsy: 14-gauge automated core-needle biopsy vs 8- or 11-gauge vacuum-assisted biopsy. Br J Radiol 2012; 85 (1016): e349-e356
  • 23 Schueller G, Schueller-Weidekamm C, Helbich TH. Accuracy of ultrasound-guided, large-core needle breast biopsy. Eur Radiol 2008; 18 (09) 1761-1773
  • 24 Ancona A, Caiffa L, Fazio V. Digital stereotactic breast microbiopsy with the mammotome: study of 122 cases [in Italian]. Radiol Med (Torino) 2001; 101 (05) 341-347
  • 25 Brem RF, Schoonjans JM, Sanow L, Gatewood OM. Reliability of histologic diagnosis of breast cancer with stereotactic vacuum-assisted biopsy. Am Surg 2001; 67 (04) 388-392
  • 26 Burak Jr WE, Owens KE, Tighe MB. et al. Vacuum-assisted stereotactic breast biopsy: histologic underestimation of malignant lesions. Arch Surg 2000; 135 (06) 700-703
  • 27 Lai JT, Burrowes P, MacGregor JH. Diagnostic accuracy of a stereotaxically guided vacuum-assisted large-core breast biopsy program in Canada. Can Assoc Radiol J 2001; 52 (04) 223-227
  • 28 Yelland A, Graham MD, Trott PA. et al. Diagnosing breast carcinoma in young women. BMJ 1991; 302 (6777): 618-620
  • 29 Bernik SF, Troob S, Ying BL. et al. Papillary lesions of the breast diagnosed by core needle biopsy: 71 cases with surgical follow-up. Am J Surg 2009; 197 (04) 473-478
  • 30 Burbank F. Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies. Radiology 1997; 204 (01) 153-156
  • 31 Tseng HS, Chen YL, Chen ST. et al. The management of papillary lesion of the breast by core needle biopsy. Eur J Surg Oncol 2009; 35 (01) 21-24
  • 32 Park HL, Hong J. Vacuum-assisted breast biopsy for breast cancer. Gland Surg 2014; 3 (02) 120-127
  • 33 Simon JR, Kalbhen CL, Cooper RA, Flisak ME. Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 2000; 215 (03) 694-697
  • 34 Johnson AT, Henry-Tillman RS, Smith LF. et al. Percutaneous excisional breast biopsy. Am J Surg 2002; 184 (06) 550-554 , discussion 554
  • 35 Bohan S, Ramli Hamid MT, Chan WY. et al. Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions. Sci Rep 2021; 11 (01) 129
  • 36 Seely JM, Hill F, Peddle S, Lau J. An evaluation of patient experience during percutaneous breast biopsy. Eur Radiol 2017; 27 (11) 4804-4811