CC BY-NC-ND 4.0 · Annals of Otology and Neurotology 2022; 05(01): 021-027
DOI: 10.1055/s-0043-1761406
Original Article

The Distensibility of Reissner’s Membrane: A Comparative Analysis

1   Department of Otolaryngology, Columbia University, New York City, New York, United States of America
› Author Affiliations

Abstract

Background Distention of Reissner’s membrane in endolymphatic hydrops is a classical otopathologic finding in cases of Meniere’s disease. A recent double hit analysis raised the possibility that the variability in the distensile behavior in Reissner’s membrane may contribute to the vagaries of membrane pathology encountered in this disease. Such distensile variability is suspected to stem from the viscoelastoplastic behavior of the type IV collagen in Reissner’s basement membrane.

Objective To analyze the known distensile characteristics of Reissner’s membrane for evidence of viscoelastoplastic behavior.

Methods Extant data on human Reissner’s membrane were analyzed for distensile characteristics. These features were then compared to the known characteristics of viscoelastoplasticity as manifested by polymers in general as well as a variety of collagenous tissues. These tissues included a synthetic collagen membrane as well as selected mammalian tissues.

Results The limited extant data on human Reissner’s membrane distensile behavior was found to manifest sigmoid load deformation at a lower strain rate of 0.47%/sec and a rigid rupture pattern at a 10-fold higher strain rate of 5.5%/sec. These characteristics were found to be similar to the general characteristics of polymer viscoelasticity, namely a sigmoid load deformation pattern at lower strain rate that stiffens and straightens as strain rate increases. Tensometric data from a synthetic collagen membrane and selected mammalian tissues were found to exhibit comparable load deformation patterns. These findings support the conclusion that human Reissner’s membrane behaves in a viscoelastoplastic manner.

Conclusions Human Reissner’s membrane appears to exhibit viscoelastoplastic behavior comparable to that observed in other collagenous tissues. Such variable distensile behavior provides insight into why the degree of lesion distention before rupture in Meniere’s disease might vary depending on the dynamics of membrane loading and the resultant rate of membrane strain.



Publication History

Article published online:
25 May 2023

© 2023. Indian Society of Otology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Paparella MM. Pathology of Meniere’s disease. Ann Otol Rhinol Laryngol Suppl 1984; 112 (4, suppl) 31-35
  • 2 Steele CR. Stiffness of Reissner’s membrane. J Acoust Soc Am 1974; 56 (04) 1252-1257
  • 3 Pender DJ. The biomechanics of lesion formation in endolymphatic hydrops: single and double hit mechanisms. Otol Neurotol 2019; 40 (03) 398-403
  • 4 Pender DJ. A model of viscoelastoplasticity in the cochleo-saccular membranes. Laryngoscope Investig Otolaryngol 2019; 4 (06) 659-662
  • 5 Roeder BA, Kokini K, Sturgis JE, Robinson JP, Voytik-Harbin SL. Tensile mechanical properties of three-dimensional type I collagen extracellular matrices with varied microstructure. J Biomech Eng 2002; 124 (02) 214-222
  • 6 Ishii T, Yamamoto N, Machida T, The Physical Strength of the Membranous Labyrinth and Its Relation to Endolymphatic Hydrops. In: Kitahara M, ed. Ménière’s Disease. Tokyo: Springer; 1990
  • 7 Tanaka M, Ishii T, Takayama M. Measurement of pressure and displacement of the membranous labyrinth in endolymphatic hydrops by the tensile test. Acta Otolaryngol Suppl 1997; 528: 30-36
  • 8 Roylance D. 2001 Engineering Viscoelasticity. March 13, 2021. Accessed October 20, 2022, at: http://ocw.mit.edu/courses/materials-science-and-engineering/3-11-mechanics-of-materials-fall-1999/modules/visco.pdf
  • 9 Su P, Yang Y, Xiao J, Song Y. Corneal hyper-viscoelastic model: derivations, experiments, and simulations. Acta Bioeng Biomech 2015; 17 (02) 73-84
  • 10 Liu X, Wang L, Ji J. et al. A mechanical model of the cornea considering the crimping morphology of collagen fibrils. Invest Ophthalmol Vis Sci 2014; 55 (04) 2739-2746
  • 11 Arumugam V, Naresh MD, Sanjeevi R. Effect of strain rate on the fracture behaviour of skin. J Biosci 1994; 19 (03) 307-313
  • 12 Bekesy G.Experiments in Hearing. New York: McGraw-Hill; 1960 Bekesy G.Experiments in Hearing. New York: McGraw-Hill; 1960
  • 13 Tonndorf J. Endolymphatic hydrops: mechanical causes of hearing loss. Arch Otorhinolaryngol 1976; 212 (04) 293-299
  • 14 Flock A, Flock B. Micro-lesions in Reissner’s membrane evoked by acute hydrops. Audiol Neurotol 2003; 8 (02) 59-69
  • 15 Shen ZL, Kahn H, Ballarini R, Eppell SJ. Viscoelastic properties of isolated collagen fibrils. Biophys J 2011; 100 (12) 3008-3015
  • 16 Guimarães CF, Gasperini L, Marques AP. The stiffness of living tissues and implications for tissue engineering. Nat Rev Mater 2020; 5: 351-370