Subscribe to RSS
DOI: 10.1055/s-0043-100218
Single tunneling method with endoscopic submucosal dissection for treatment of a rectal giant (18-cm) laterally spreading tumor
Publication History
Publication Date:
22 February 2017 (online)
Endoscopic submucosal dissection (ESD) is an effective method for en bloc complete resection of lesions. We report a case of an 18-cm laterally spreading tumor (LST) in the colon that was successfully removed by colorectal ESD using a tunneling technique.
The patient was a 61-year-old man who had a giant LST at the rectum starting 3 cm from the anal canal and extending proximally, measuring 13 cm endoscopically ([Fig. 1]). The procedure was performed after he had been sedated using spinal anesthesia. The lesion was examined by chromoendoscopy and endoscopic ultrasonography before ESD. The ESD strategy involved creating a tunnel from the anal site to a point proximal to the rectum, then joining the tunnel to the left part of the lesion using incision and dissection. Finally, the dissected part and the right part of the lesion were connected using incision and dissection assisted by gravity ([Fig. 2], [Video 1]). The time between the initial incision and the separation of the lesion from normal tissue was recorded as the duration of the procedure.
Video 1: Single tunneling technique with endoscopic submucosal dissection for treatment of a rectal giant lateral spreading tumor.Quality:
The resected tumor was removed en bloc and measured 179 × 108 mm ([Fig. 3]). The procedure time was 224 min. Examination of the pathological specimen showed intramucosal carcinoma, and all of the margins were clear. No complications occurred during or after the procedures ([Fig. 4]). No residual tissue was seen on control colonoscopy ([Fig. 5]).
The single tunneling technique may easily provide orientation during procedures with controlled dissection of huge lesions. In addition, this method can allow effective isolation and coagulation of the main blood vessels rather than vessel branches. Therefore, as excessive bleeding is prevented, it can help the endoscopist to obtain a cleaner submucosal layer and increase the quality of the procedure. We consider that these advantages may be beneficial for increasing the quality of the sample and removing huge lesions en bloc, decreasing the total procedure duration and helping the endoscopist to use operating time effectively.
Endoscopy_UCTN_Code_TTT_1AQ_2AD