J Knee Surg 2022; 35(14): 1540-1543
DOI: 10.1055/s-0042-1758551
Special Focus Section

Two-Year Survivorship and Outcomes of a Three-Dimensional Printed Metaphyseal Cone in the Setting of Revision Total Knee Arthroplasty

Rubén Monárrez
1   Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Replacement, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
,
Sandeep S. Bains
1   Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Replacement, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
,
1   Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Replacement, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
,
Oliver C. Sax
1   Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Replacement, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
,
Christopher G. Salib
1   Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Replacement, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
,
Michael A. Mont
1   Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Replacement, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
,
1   Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Replacement, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
› Author Affiliations

Abstract

Poor metaphyseal fixation secondary to bone loss in revision total knee arthroplasty (TKA) continues to be challenging. One technique to increase implant stability is the use of novel three-dimensional (3D) printed titanium metaphyseal cones with adjunctive stems for added fixation. However, the survival of these novel constructs is poorly understood. Therefore, we sought to examine 3D-printed titanium metaphyseal cone components in revision TKA for aseptic as well as septic reasons and aimed to evaluate: (1) revision-free survivorships; (2) patient-reported outcomes measures (PROMs); (3) postoperative medical complications; and (4) radiographic outcomes. A consecutive series of 62 patients who underwent revision TKA with use of a titanium metaphyseal cone at a single institution between September 1, 2015 and May 31, 2021 were examined. The patients had a minimum follow-up period of 2 years (mean, 40 months, range, 24–72 months). PROMS included Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS-JR) scores at baseline and last clinical follow-up. Overall, when excluding infections, the combined implant survivorship was 96% (52 out of 54), while it was 95% (35 out of 57) for aseptic revisions and 100% (17 out of 17) for septic revisions. Reasons for revisions within the aseptic revision cohort included loosening (5%) as well as periprosthetic joint infections (PJIs) (7.5%). All failures following an index septic revision were due to PJI. Mean KOOS scores at baseline as well as at final follow-up was 43 points (range, 16–80) and 70 points (range, 34–100), respectively. None of the patients had medical complications. Other than the loosening reported (only femoral component), of the surviving patients no patients had evidence of progressive radiolucencies. The use of titanium cones in revision TKA provides good revision-free survivorship at 2 years. Further research is warranted on the longer-term survivorship of 3D-printed titanium cones. The current study has found that 3D-printed titanium cones can be incorporated as part of the revision knee surgeon's armamentarium.



Publication History

Received: 09 August 2022

Accepted: 29 September 2022

Article published online:
20 December 2022

© 2022. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Mulhall KJ, Ghomrawi HM, Engh GA, Clark CR, Lotke P, Saleh KJ. Radiographic prediction of intraoperative bone loss in knee arthroplasty revision. Clin Orthop Relat Res 2006; 446: 51-58
  • 2 Remily EA, Dávila Castrodad IM, Mohamed NS, Wilkie WA, Kelemen MN, Delanois RE. Short-term outcomes of 3D-printed titanium metaphyseal cones in revision total knee arthroplasty. Orthopedics 2021; 44 (01) 43-47
  • 3 Faizan A, Bhowmik-Stoker M, Alipit V. et al. Development and verification of novel porous titanium metaphyseal cones for revision total knee arthroplasty. J Arthroplasty 2017; 32 (06) 1946-1953
  • 4 Anderson LA, Christie M, Blackburn BE. et al. 3D-printed titanium metaphyseal cones in revision total knee arthroplasty with cemented and cementless stems. Bone Joint J 2021; 103-B (supple 6A): 150-157
  • 5 Sultan AA, Mahmood B, Samuel LT. et al. Cementless 3D printed highly porous titanium-coated baseplate total knee arthroplasty: survivorship and outcomes at 2-year minimum follow-up. J Knee Surg 2020; 33 (03) 279-283
  • 6 Tetreault MW, Perry KI, Pagnano MW, Hanssen AD, Abdel MP. Excellent two-year survivorship of 3D-printed metaphyseal cones in revision total knee arthroplasty. Bone Joint J 2020; 102-B (suppl_6A): 107-115
  • 7 Bohl DD, Brown NM, McDowell MA. et al. Do porous tantalum metaphyseal cones improve outcomes in revision total knee arthroplasty?. J Arthroplasty 2018; 33 (01) 171-177
  • 8 Brown NM, Bell JA, Jung EK, Sporer SM, Paprosky WG, Levine BR. The use of trabecular metal cones in complex primary and revision total knee arthroplasty. J Arthroplasty 2015; 30 (Suppl. 09) 90-93