CC BY 4.0 · Eur J Dent 2022; 16(02): 454-457
DOI: 10.1055/s-0041-1736315
Case Report

T-Scan Novus System in the Management of Splints—Pilot Study

1   Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University, Plovdiv, Bulgaria
,
1   Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University, Plovdiv, Bulgaria
› Institutsangaben
Funding This study was funded by Medical University - Plovdiv, Bulgaria (grant no. 13/2020).

Abstract

The purpose of this pilot study was to demonstrate the capabilities of the T-Scan Novus system in bruxism treatment by splints. Bruxism patients underwent treatment with a splint made by additive manufacturing. Intraoral scanning was performed using Trios Color (3Shape), and digital design was performed using 3Shape Dental system design - splint studio. The biocompatible material Dental LT Clear Resin was printed using a Formlabs Form 2 printer. The T-Scan Novus system with a software attached to it, version 9.1, was used for digital examination of the occlusion. A splint with an occlusal thickness of 2.5 mm was developed and software adapted with relief to antagonists. The digitally set occlusion with even contacts turned out to be clinically unbalanced. After adjusting with T-Scan Novus, a balanced occlusion was achieved in the right and left halves. The treatment of bruxism with splint therapy continues to be the main method. Its combination with digital technologies allows more precise constructions and more accurate balancing of occlusal relationships.

Authors' Contributions

Both the authors read and agreed to the published version of the manuscript.




Publikationsverlauf

Artikel online veröffentlicht:
04. Dezember 2021

© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Bumann A, Lotzmann U. TMJ Disorders and Orofacial Pain. Stuttgart, New York: Thieme; 2002: 308-319
  • 2 Okeson JP. Management of Temporomandibular Disorders and Occlusion-E-Book. 8th ed.. Elsevier Health Sciences; 2019: 423-430
  • 3 Moin H, Rao DC, Sujesh M, Kumar CR, Harilal G. Occlusal splint therapy-A review. Paripex-Indian Journal of Research 2019; 8 (02) 17-20
  • 4 Al-Ani MZ, Davies SJ, Gray RJ, Sloan P, Glenny AM. Stabilisation splint therapy for temporomandibular pain dysfunction syndrome. Cochrane Database Syst Rev 2004; (01) CD002778
  • 5 Taneva I, Grozdanova-Uzunova R, Uzunov T. Occlusal splints–changes in the muscular activity. Journal of Physics: Conference Series IOP Publishing 2021; 1859 (01) 012046
  • 6 Karakis D, Dogan A, Bek B. Evaluation of the effect of two different occlusal splints on maximum occlusal force in patients with sleep bruxism: a pilot study. J Adv Prosthodont 2014; 6 (02) 103-108
  • 7 Guaita M, Högl B. Current Treatments of Bruxism. Curr Treat Options Neurol 2016; 18 (02) 10 DOI: 10.1007/s11940-016-0396-3.
  • 8 Dubé C, Rompré PH, Manzini C, Guitard F, de Grandmont P, Lavigne GJ. Quantitative polygraphic controlled study on efficacy and safety of oral splint devices in tooth-grinding subjects. J Dent Res 2004; 83 (05) 398-403
  • 9 Berntsen C, Kleven M, Heian M, Hjortsjö C. Clinical comparison of conventional and additive manufactured stabilization splints. Acta Biomater Odontol Scand 2018; 4 (01) 81-89
  • 10 Salmi M, Paloheimo KS, Tuomi J, Ingman T, Mäkitie A. A digital process for additive manufacturing of occlusal splints: a clinical pilot study. J R Soc Interface 2013; 10 (84) 20130203
  • 11 Venezia P, Muzio LL, De Furia C, Torsello F. Digital manufacturing of occlusal splint: From intraoral scanning to 3D printing. Journal of Osseointegration 2019; 11 (04) 535-539
  • 12 Nota A, Ryakhovsky AN, Bosco F, Tecco S. A full digital workflow to design and mill a splint for a patient with temporomandibular joint disorder. Appl Sci (Basel) 2021; 11 (01) 372
  • 13 Kerstein RB. Articulating paper mark misconceptions and computerized occlusal analysis technology. Dent Implantol Update 2008; 19 (06) 41-46
  • 14 Carey JP, Craig M, Kerstein RB, Radke J. Determining a relationship between applied occlusal load and articulating paper mark area. Open Dent J 2007; 1: 1-7
  • 15 Chutchalermpan T, Pumklin J, Piyapattamin T. Evaluation of disclusion time in various angle's malocclusions by T-Scan III system. Eur J Dent 2019; 13 (04) 510-513
  • 16 Cohen-Levy J, Cohen N. Computerized analysis of occlusal contacts after lingual orthodontic treatment in adults. Int Orthod 2011; 9 (04) 410-431
  • 17 Hützen D, Rebau M, Kordass B. Clinical reproducibility of GEDAS–“Greifswald Digital Analyzing System” for displaying occlusal contact patterns. Int J Comput Dent 2006; 9 (02) 137-142
  • 18 Koos B, Godt A, Schille C, Göz G. Precision of an instrumentation-based method of analyzing occlusion and its resulting distribution of forces in the dental arch. J Orofac Orthop 2010; 71 (06) 403-410
  • 19 Ruttitivapanich N, Tansalarak R, Palasuk J, Pumklin J. Correlation of bite force interpretation in maximal intercuspal position among patient, clinician, and T-Scan III system. Eur J Dent 2019; 13 (03) 330-334
  • 20 Karakis D, Demirdag ED. Adjustment of occlusal splint with synchronized T-Scan III digital occlusal analysis system and Bio-EMG III in a patient with sleep bruxism. Journal of Advanced Oral Research 2021; 12 (01) 170-175
  • 21 Saraçoğlu A, Ozpinar B. In vivo and in vitro evaluation of occlusal indicator sensitivity. J Prosthet Dent 2002; 88 (05) 522-526