Subscribe to RSS
DOI: 10.1055/s-0041-1732437
Detection of Direct Oral Anticoagulants in Patient Urine Samples by Prototype and Commercial Test Strips for DOACs – A Systematic Review and Meta-analysis
Abstract
The DOAC Dipstick accurately detects the presence or absence of factor Xa (DXI) and thrombin inhibitor (DTI) classes of direct oral anticoagulants (DOACs) in patients' urine samples on DOAC treatment. The aim of the study was to systematically review the literature and compare the performance of prototype and commercial test strips with a meta-analysis.
A systematic literature search of electronic databases PubMed (MEDLINE) and Cochrane Library was performed. Heterogeneity between studies was calculated using the Chi-squared test and the I2 index. A random effects model was used to pool data to compare the performance of prototype and commercial test strips.
Using PRISMA reporting guidelines, four of 1,081 publications were eligible for inclusion in the meta-analysis: three reporting on prototype (DXI n = 658, DTI n = 586) and one on commercial test strips (DXI n = 451, DTI n = 429). Sensitivity and specificity of DXI and DTI detection did not differ significantly between the prototype and commercial test strips. Odds ratios were 0.718 and 0.365 for sensitivity and 1.211 and 1.072 for specificity of DXI and DTI (p-values between 0.3334 and 1.000), respectively. The pooled sensitivity and specificity values for DXI were 0.968 (p = 0.1290, I2 47.1%) and 0.979 (p = 0.1965, I2 35.9%), and for DTI 0.993 (p = 0.1870, I2 37.5%) and 0.993 (p = 0.7380, I2 0%), respectively.
Prototype and commercial DOAC test strips did not differ in their ability to detect DXI and DTI in patient urine samples. This supports the confidence in use of the DOAC Dipstick test, although it needs to be validated in specific patient populations.
Disclosure of Conflict of Interest
AM, SH, CW: no conflict to disclose.
JBW: Grants and personal fees from Bayer, grants and personal fees from Daiichi Sankyo, grants and personal fees from DOASENSE, grants and personal fees from Portola, grants from Pfizer.
JH: Founder and managing director of DOASENSE, GmbH. Not related to this work: a patent US 9,133,501 licensed, a patent EU 2643475 licensed, a patent US 9,944,971 licensed, and a patent EU 2723886 licensed.
IE: Grants and personal fees from Boehringer Ingelheim, grants and personal fees from Bayer, grants and personal fees from Pfizer, grants and personal fees from Bristol Myers Squibb.
MC: Grants from Bayer, personal fees from Shionogi, personal fees from Alexion, grants from Leo pharma, personal fees from Pfizer and Daiichi, grants from Heart and Stroke Foundation, other funding from Alnylam, personal fees from Octapharma, personal fees from Bristol Myers Squibb Canada, personal fees from CSL Behring, personal fees from Alexion, personal fees from Servier Canada, personal fees from Diagnostica Stago, personal fees from Asahi Kasei.
RB: Personal fees from DOASENSE GmbH, personal fees from Bayer AG, personal fees from Bristol Myers Squibb, personal fees from Daichii Sankyo, personal fees from Pfizer.
Publication History
Received: 17 June 2021
Accepted: 28 June 2021
Article published online:
24 September 2021
© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Choi SY, Kim MHH, Lee KM. et al. Age-dependent anticoagulant therapy for atrial fibrillation patients with intermediate risk of ischemic stroke: A nationwide population-based study. Thromb Haemost 2020; Dec 11 DOI: 10.1055/a-1336-0476.
- 2 Dentali F, Crowther M. Venous thromboembolism, age and hospitalisation: A potentially deadly combination. Thromb Haemost 2010; 104 (04) 655-656
- 3 Lip GYH, Collet JP, de Caterina R. et al. Antithrombotic Therapy in Atrial Fibrillation Associated with Valvular Heart Disease: Executive Summary of a Joint Consensus Document from the European Heart Rhythm Association (EHRA) and European Society of Cardiology Working Group on Thrombosis, Endorsed by the ESC Working Group on Valvular Heart Disease, Cardiac Arrhythmia Society of Southern Africa (CASSA), Heart Rhythm Society (HRS), Asia Pacific Heart Rhythm Society (APHRS), South African Heart (SA Heart) Association and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLEACE). Thromb Haemost 2017; 117 (12) 2215-2236
- 4 Ortel TL, Neumann I, Ageno W. et al. American Society of Hematology 2020 guidelines for management of venous thromboembolism: treatment of deep vein thrombosis and pulmonary embolism. Blood Adv 2020; 4 (19) 4693-4738
- 5 Chan N, Sobieraj-Teague M, Eikelboom JW. Direct oral anticoagulants: evidence and unresolved issues. Lancet 2020; 396 (10264): 1767-1776
- 6 Douxfils J, Ageno W, Samama CM. et al. Laboratory testing in patients treated with direct oral anticoagulants: a practical guide for clinicians. J Thromb Haemost 2018; 16 (02) 209-219
- 7 Gosselin RC, Adcock DM, Bates SM. et al. International Council for Standardization in Haematology (ICSH) Recommendations for Laboratory Measurement of Direct Oral Anticoagulants. Thromb Haemost 2018; 118 (03) 437-450
- 8 Gómez-Outes A, Suárez-Gea ML, Lecumberri R, Terleira-Fernández AI, Vargas-Castrillón E. Direct-acting oral anticoagulants: pharmacology, indications, management, and future perspectives. Eur J Haematol 2015; 95 (05) 389-404
- 9 Harenberg J, Du S, Krämer S. et al. Novel methods for assessing oral direct factor Xa and thrombin inhibitors: use of point-of-care testing and urine samples. Semin Thromb Hemost 2013; 39 (01) 66-71
- 10 Harenberg J, Schreiner R, Hetjens S, Weiss C. Detecting Anti-IIa and Anti-Xa Direct Oral Anticoagulant (DOAC) Agents in Urine using a DOAC Dipstick. Semin Thromb Hemost 2019; 45 (03) 275-284
- 11 Harenberg J, Beyer-Westendorf J, Crowther M. et al; Working Group Members. Accuracy of a Rapid Diagnostic Test for the Presence of Direct Oral Factor Xa or Thrombin Inhibitors in Urine-A Multicenter Trial. Thromb Haemost 2020; 120 (01) 132-140
- 12 Harenberg J, Warttinger U, Hetjens S. et al. Reliability and validity of a point of care test from urine samples of patients on therapy with Apixaban, rivaroxaban and dabigatran. Res Pract Thromb Haemost 2017; 1 (Suppl. 01) PB454
- 13 Whiting PF, Rutjes AW, Westwood ME. et al; QUADAS-2 Group. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 2011; 155 (08) 529-536
- 14 Higgins JP, Altman DG, Gøtzsche PC. et al; Cochrane Bias Methods Group, Cochrane Statistical Methods Group. The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. BMJ 2011; 343: d5928
- 15 Zamora J, Abraira V, Muriel A, Khan K, Coomarasamy A. Meta-DiSc: a software for meta-analysis of test accuracy data. BMC Med Res Methodol 2006; 6 (07) 31 DOI: 10.1186/1471-2288-6-31.
- 16 DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials 1986; 7 (03) 177-188
- 17 Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ 2003; 327 (7414): 557-560
- 18 Jones CM, Athanasiou T. Summary receiver operating characteristic curve analysis techniques in the evaluation of diagnostic tests. Ann Thorac Surg 2005; 79 (01) 16-20
- 19 Moher D, Liberati A, Tetzlaff J, Altman DG. PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. J Clin Epidemiol 2009; 62 (10) 1006-1012
- 20 Harenberg J, Krämer S, Du S, Weiss C, Krämer R. Concept of a point of care test to detect new oral anticoagulants in urine samples. Thromb J 2013; 11 (01) 15 DOI: 10.1186/1477-9560-11-15.
- 21 Harenberg J, Du S, Wehling M. et al. Measurement of dabigatran, rivaroxaban and apixaban in samples of plasma, serum and urine, under real life conditions. An international study. Clin Chem Lab Med 2016; 54 (02) 275-283
- 22 Harenberg J, Martini A, Du S, Krämer S, Weiss C, Hetjens S. Performance characteristics of DOAC Dipstick in determining direct oral anticoagulants in urine. Clin Appl Thromb Hemost 2021; 27: 1076029621993550 DOI: 10.1177/1076029621993550.
- 23 Schäfer ST, Wiederkehr T, Kammerer T. et al. Real-time detection and differentiation of direct oral anticoagulants (rivaroxaban and dabigatran) using modified thromboelastometric reagents. Thromb Res 2020; 190 (06) 103-111
- 24 Härtig F, Birschmann I, Peter A. et al. Point-of-care testing for emergency assessment of coagulation in patients treated with direct oral anticoagulants including edoxaban. Neurol Res Pract.. 2021 Mar 1;3(1):9. doi: 10.1186/s42466-021-00105-4. PMID: 336
- 25 Härtig F, Birschmann I, Peter A. et al. Specific point- of-care testing of coagulation in outients treated with dabigatran. Thromb Haemost 2021; 121 (06) 782-791
- 26 Maji D, Opneja A, Suster MA. et al. Monitoring DOACs with a novel dielectric microsensor: A clinical study. Thromb Haemost 2021; 121 (01) 58-69
- 27 Douxfils J, Adcock DM, Bates SM. et al. 2021 Update of the International Council for Standardization in Haematology Recommendations for Laboratory Measurement of Direct Oral Anticoagulants. Thromb Haemost 2021; 121 (08) 1008-1020
- 28 de Menezes Neves PDM, Coelho Ferreira BM, Mohrbacher S, Renato Chocair P, Cuvello-Neto AL. Purple urine bag syndrome: a colourful complication of urinary tract infection. Lancet Infect Dis 2020; 20 (10) 1215 DOI: 10.1016/S1473-3099(20)30323-6.
- 29 Dicko A, Roh ME, Diawara H. et al. Efficacy and safety of primaquine and methylene blue for prevention of Plasmodium falciparum transmission in Mali: a phase 2, single-blind, randomised controlled trial. Lancet Infect Dis 2018; 18 (06) 627-639
- 30 Sawicki T, Topolska J, Bączek N. et al. Characterization of the profile and concentration of betacyanin in the gastric content, blood and urine of rats after an intragastric administration of fermented red beet juice. Food Chem. 2020 30(5) 313:126169.
- 31 Echeverry G, Hortin GL, Rai AJ. Introduction to urinalysis: historical perspectives and clinical application. Methods Mol Biol 2010; 641 (01) 1-12
- 32 Jilma B, Buchtele N, Merrelaar A. et al. Dark-coloured urine impacts test results of the novel DOAC Dipstick point-of-care strip test. Res Pract Thromb Haemost. 2019 ,3:S1, PB 191
- 33 Borenstein M, Hedges LV, Higgins JP, Rothstein HR. A basic introduction to fixed-effect and random-effects models for meta-analysis. Res Synth Methods 2010; 1 (02) 97-111
- 34 Giustozzi M, Agnelli G, Del Toro-Cervera J. et al. Direct oral anticoagulants for the treatment of acute venous thromboembolism associated with cancer: A systematic review and meta-analysis. Thromb Haemost 2020; 120 (07) 1128-1136
- 35 Lee YH. An overview of meta-analysis for clinicians. Korean J Intern Med (Korean Assoc Intern Med) 2018; 33 (02) 277-283
- 36 NICE. DOAC Dipstick for detecting direct oral anticoagulants Medtech innovation briefing [MIB248] Published date: 02 February. 2021 https://www.nice.org.uk/advice/mib248 , assessed April 10th 2021
- 37 Gemeinsamer Bundesausschuss über eine Änderung der Richtlinie zur Versorgung der hüftgelenknahen Femurfraktur:. https://www.g-ba.de/beschluesse/4655/ assessed April 10th 2021
- 38 Harenberg J, Bauersachs R, Ageno W. Does Chronic Treatment with Oral Anticoagulants Ameliorate the Clinical Course of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Infection in Coronavirus Disease 2019 (COVID-19)?. Semin Thromb Hemost 2021; 47 (04) 338-340