Abstract
Oxidized zirconium (OxZr) femoral heads were developed to emulate the superior wear and scratch properties of ceramics while eliminating their unwanted tendency for brittle fracturing. Studies using OxZr have demonstrated reduced linear and volumetric wear of polyethylene (PE) liners when compared with cobalt chrome, ceramic, and steel femoral heads. The purpose of this systematic review was to determine the difference in revision rates, radiologically determined linear wear rates, and patient-reported outcomes among OxZr and alternative bearing materials. Following the Preferred Reporting Items for Systematic Review and Meta-Analysis protocols, a systematic review of published literature through April 24, 2018 was conducted. Among the 862 cases included at a mean weighted follow-up of 4.78 years, the revision THA rate and patient-reported outcomes were similar among OxZr and alternative bearing materials. One of the five studies demonstrated significantly lower linear wear rates in the OxZr group when paired with ultrahigh molecular-weight PE (OxZr 0.03 mm/y vs. stainless-steel 0.11 mm/y; p < 0.001) and when paired with highly-crosslinked PE (OxZr 0.02 mm/y vs. stainless-steel 0.04 mm/y; p < 0.001). The remaining four studies found no difference in linear wear rates. OxZr demonstrated similar outcome to that of modern-day ceramic and metal femoral heads for short- and mid-term revision surgery rates and patient-reported outcomes. Longer term studies are needed to evaluate if any long-term wear advantages are seen with the use of OxZr femoral heads and if the use of OxZr is cost effective compared with ceramic or metal alternatives. The level of evidence of the study is level II, systematic review.
Publication History
Received: 23 April 2020
Accepted: 05 June 2020
Article published online:
22 September 2020
© 2020. Thieme. All rights reserved.
Thieme Medical Publishers
333 Seventh Avenue, New York, NY 10001, USA.
-
References
- 1 Neumann PJ, Cohen JT, Weinstein MC. Updating cost-effectiveness—the curious resilience of the $50,000-per-QALY threshold. N Engl J Med 2014; 371 (09) 796-797
- 2 Daigle ME, Weinstein AM, Katz JN, Losina E. The cost-effectiveness of total joint arthroplasty: a systematic review of published literature. Best Pract Res Clin Rheumatol 2012; 26 (05) 649-658
- 3 Elmallah RK, Chughtai M, Khlopas A. , et al. Determining cost-effectiveness of total hip and knee arthroplasty using the short form-6D utility measure. J Arthroplasty 2017; 32 (02) 351-354
- 4 Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clin Orthop Relat Res 2009; 467 (10) 2606-2612
- 5 Wolford ML, Palso K, Bercovitz A. Hospitalization for total hip replacement among inpatients aged 45 and over: United States, 2000–2010. NCHS Data Brief 2015; (186) 1-8
- 6 Mistry JB, Chughtai M, Elmallah RK. , et al. Trunnionosis in total hip arthroplasty: a review. J Orthop Traumatol 2016; 17 (01) 1-6
- 7 Tan SC, Lau ACK, Del Balso C, Howard JL, Lanting BA, Teeter MG. Tribocorrosion: ceramic and oxidized zirconium vs cobalt-chromium heads in total hip arthroplasty. J Arthroplasty 2016; 31 (09) 2064-2071
- 8 McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD. Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Joint Surg Am 2009; 91 (04) 773-782
- 9 Baek S-H, Kim WK, Kim JY, Kim SY. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?. Clin Orthop Relat Res 2015; 473 (12) 3796-3802
- 10 Hamilton WG, McAuley JP, Dennis DA, Murphy JA, Blumenfeld TJ, Politi J. THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial. Clin Orthop Relat Res 2010; 468 (02) 358-366
- 11 Hunter G, Jones WM, Spector M. Oxidised zirconium. In: Bellemans J, Ries M, Victor J. , eds. Total Knee Arthroplasty. Heidelberg: Springer-Verlag; 2005
- 12 Patel AM, Spector M. Tribological evaluation of oxidized zirconium using an articular cartilage counterface: a novel material for potential use in hemiarthroplasty. Biomaterials 1997; 18 (05) 441-447
- 13 Good V, Ries M, Barrack RL, Widding K, Hunter G, Heuer D. Reduced wear with oxidized zirconium femoral heads. J Bone Joint Surg Am 2003; 85-A (Suppl. 04) 105-110
- 14 Karidakis GK, Karachalios T. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study. Clin Orthop Relat Res 2015; 473 (12) 3836-3845
- 15 Zaoui A, Hage SE, Langlois J, Scemama C, Courpied JP, Hamadouche M. Do oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial. Clin Orthop Relat Res 2015; 473 (12) 3822-3828
- 16 Petis SM, Vasarhelyi EM, Lanting BA. , et al. Mid-term survivorship and clinical outcomes of cobalt-chrome and oxidized zirconium on highly crosslinked polyethylene. Can J Surg 2016; 59 (01) 48-53
- 17 Kadar T, Dybvik E, Hallan G, Furnes O, Havelin LI. Head material influences survival of a cemented total hip prosthesis in the Norwegian Arthroplasty Register. Clin Orthop Relat Res 2012; 470 (11) 3007-3013
- 18 Morison ZA, Patil S, Khan HA, Bogoch ER, Schemitsch EH, Waddell JP. A randomized controlled trial comparing oxinium and cobalt-chrome on standard and cross-linked polyethylene. J Arthroplasty 2014; 29 (Suppl. 09) 164-168
- 19 Jassim SS, Patel S, Wardle N. , et al. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial. Bone Joint J 2015; 97-B (07) 883-889
- 20 Jonsson BA, Kadar T, Havelin LI. , et al. Oxinium modular femoral heads do not reduce polyethylene wear in cemented total hip arthroplasty at five years: a randomised trial of 120 hips using radiostereometric analysis. Bone Joint J 2015; 97-B (11) 1463-1469
- 21 Kadar T, Hallan G, Aamodt A. , et al. Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or oxinium femoral heads: a randomized radiostereometric study of 150 patients. J Orthop Res 2011; 29 (08) 1222-1229
- 22 Bourne RB, Barrack R, Rorabeck CH, Salehi A, Good V. Arthroplasty options for the young patient: oxinium on cross-linked polyethylene. Clin Orthop Relat Res 2005; 441 (441) 159-167
- 23 Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P. The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res 2004; (429) 6-16
- 24 Wroblewski BM, Siney PD, Dowson D, Collins SN. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg Br 1996; 78 (02) 280-285
- 25 Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty 2001; 16 (02) 149-160
- 26 Allain J, Roudot-Thoraval F, Delecrin J, Anract P, Migaud H, Goutallier D. Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg Am 2003; 85 (05) 825-830