CC BY-NC-ND 4.0 · Revista Argentina de Radiología / Argentinian Journal of Radiology 2019; 83(02): 049-055
DOI: 10.1055/s-0039-1692206
Original Article | Artículo Original
Sociedad Argentina de Radiología. Publicado por Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil

Concordancia Interobservador para la Validación del PI-RADS v2

Interobserver Agreement for the PI-RADS v2 Validation
1   Radiólogo de la Facultad de Medicina Clínica Alemana de Santiago, Universidad del Desarrollo, Vitacura, Chile
,
Claudio Silva Fuente-Alba
1   Radiólogo de la Facultad de Medicina Clínica Alemana de Santiago, Universidad del Desarrollo, Vitacura, Chile
,
Giancarlo Schiappacasse F
1   Radiólogo de la Facultad de Medicina Clínica Alemana de Santiago, Universidad del Desarrollo, Vitacura, Chile
,
Daniela Barahona Z
1   Radiólogo de la Facultad de Medicina Clínica Alemana de Santiago, Universidad del Desarrollo, Vitacura, Chile
,
2   Residente de Radiología Facultad de Medicina Clínica Alemana de Santiago, Universidad del Desarrollo, Vitacura, Chile
› Author Affiliations
Further Information

Publication History

10 September 2018

08 May 2019

Publication Date:
25 July 2019 (online)

Resumen

Objetivo Evaluar la variabilidad interobservador en el uso de la versión 2.0 del PI-RADS (PI-RADS v2), en lectores experimentados y no experimentados.

Materiales y Métodos Estudio retrospectivo de análisis de concordancia de lectores. Entre enero de 2015 y diciembre de 2016, 1.656 sujetos fueron estudiados mediante resonancia magnética multiparamétrica (RMmp) de próstata en nuestra institución. Se estimó la distribución porcentual del reporte en categoría PI-RADS v2, y con esa información, se realizó una selección de 150 casos con esquema de aleatorización estratificada a las distribuciones porcentuales de cada categoría. Dichos casos fueron anonimizados, presentados a tres lectores con cinco, cuatro y dos años de experiencia en lectura de RMmp además de tener más de un año de experiencia en el uso del PI-RADS v2 siendo leídos en forma individual. Los datos resultantes fueron analizados en forma independiente por un cuarto investigador.

Resultados El valor de kappa ponderado para los observadores fue de 0,69 (IC 95: 0,64 a 0,75). La mayor concordancia correspondió a los lectores de mayor experiencia, donde alcanza un valor de 0,72 (IC 95%: 0,69 a 0,76). La concordancia entre los valores PI-RADS que determinan seguimiento o bien una intervención de acuerdo a elementos clínicos (1–2–3) y conducta activa (4–5) correspondió a 0,70 (IC 95%: 0,59 a 0,78).

Discusión Se logró demostrar un acuerdo sustancial entre radiólogos utilizando el PI-RADS v2 para la detección en RMmp de lesiones sospechosas, mayor entre los dos lectores más experimentados. Sin embargo, la comparación del lector de menor experiencia con los de mayor experiencia también presentó una importante concordancia. Los valores de concordancia entre observadores para PI-RADS ≥4 fueron similares a los reportados en la literatura.

Conclusiones El PI-RADS v2 ha demostrado en nuestro centro, con radiólogos dedicados a imágenes de abdomen y estudios de próstata, un alto nivel de acuerdo en la interpretación de la RMmp de próstata, encontrándose a tono con lo reportado en la literatura.

Abstract

Purpose To evaluate the interobserver variability in the use of the PI-RADS 2.0 version, in experienced and non-experienced readers.

Material and Methods Retrospective study of readers' concordance analysis. Between January 2015 and December 2016, 1656 subjects were studied through multiparametric MRI (RMmp) of prostate in our institution. The percentage distribution of the report was estimated in each PI-RADS category, and a selection of 150 cases with a stratified randomization scheme was made to the percentage distributions of every category. These cases were anonymized, presented to three readers with 5, 4 and 2 years' experience in reading RMmp, and more than one-year experience with PI-RADS v2, and were read individually. The resulting data were analyzed independently by a fourth investigator.

Results The weighted kappa value for the observers was 0.69 (IC 95: 0.64 to 0.75). The highest agreement corresponded to the two most experienced readers, where it reached a value of 0.72 (95% CI: 0.69 to 0.76). The concordance between the PI-RADS values that determine follow-up (1–2–3) and active behavior (4–5) corresponded to 0.70 (95% CI: 0.59 to 0.78).

Discussion It was possible to demonstrate a substantial agreement between radiologists using the PI-RADS v2 for the detection in RMmp of suspicious lesions, greater among the two most experienced readers. However, the comparison of the less experienced reader with those of greater experience also presented an important concordance. The inter-observer concordance values for PI-RADS ≥4 were like those reported in the literature.

Conclusions The PI-RADS v2 has demonstrated, in our center, with radiologists dedicated to abdominal images and prostate studies, a high level of agreement in the interpretation of prostate MRmp.

Responsabilidades Éticas

Protección de personas y animales. Los autores declaran que para esta investigación no se han realizado experimentos en seres humanos ni en animales.


Confidencialidad de los datos. Los autores declaran que han seguido los protocolos de su centro de trabajo sobre la publicación de datos de pacientes.


Derecho a la privacidad y consentimiento informado. Los autores declaran que en este artículo no aparecen datos de pacientes.


 
  • Bibliografía

  • 1 Park SY, Jung DC, Oh YT. , et al. Prostate Cancer: PI-RADS Version 2 Helps Preoperatively Predict Clinically Significant Cancers. Radiology 2016; 280 (01) 108-116
  • 2 Dickinson L, Ahmed HU, Allen C. , et al. Scoring systems used for the interpretation and reporting of multiparametric MRI for prostate cancer detection, localization, and characterization: could standardization lead to improved utilization of imaging within the diagnostic pathway?. J Magn Reson Imaging 2013; 37 (01) 48-58
  • 3 Weinreb JC, Barentsz JO, Choyke PL. , et al. PI-RADS Prostate Imaging - Reporting and Data System: 2015, Version 2. Eur Urol 2016; 69 (01) 16-40
  • 4 Barentsz JO, Richenberg J, Clements R. , et al; European Society of Urogenital Radiology. ESUR prostate MR guidelines 2012. Eur Radiol 2012; 22 (04) 746-757
  • 5 Zhao C, Gao G, Fang D. , et al. The efficiency of multiparametric magnetic resonance imaging (mpMRI) using PI-RADS Version 2 in the diagnosis of clinically significant prostate cancer. Clin Imaging 2016; 40 (05) 885-888
  • 6 Rosenkrantz AB, Ginocchio LA, Cornfeld D. , et al. Interobserver Reproducibility of the PI-RADS Version 2 Lexicon: A Multicenter Study of Six Experienced Prostate Radiologists. Radiology 2016; 280 (03) 793-804
  • 7 Muller BG, Shih JH, Sankineni S. , et al. Prostate Cancer: Interobserver Agreement and Accuracy with the Revised Prostate Imaging Reporting and Data System at Multiparametric MR Imaging. Radiology 2015; 277 (03) 741-750
  • 8 Chen F, Cen S, Palmer S. Application of Prostate Imaging Reporting and Data System Version 2 (PI-RADS v2): Interobserver Agreement and Positive Predictive Value for Localization of Intermediate- and High-Grade Prostate Cancers on Multiparametric Magnetic Resonance Imaging. Acad Radiol 2017; 24 (09) 1101-1106
  • 9 Girometti R, Giannarini G, Greco F. , et al. Interreader agreement of PI-RADS v. 2 in assessing prostate cancer with multiparametric MRI: A study using whole-mount histology as the standard of reference. J Magn Reson Imaging 2019; 49 (02) 546-555