CC BY-NC-ND 4.0 · Eur J Dent 2019; 13(01): 069-074
DOI: 10.1055/s-0039-1688539
Original Article
Dental Investigation Society

In Vivo Measurement of Root Canal Wall Temperature at Different Stages Prior to Fiber Post Cementation

Ana Carolina Rocha Lima Caiado
1   Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
,
Cristiana Godoy Sartori Azevedo
1   Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
,
Marcelo Giannini
1   Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
,
Mario Fernando De Goes
1   Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
,
Frederick Allen Rueggeberg
2   Department of Restorative Sciences, Dental College of Georgia, Augusta University, Augusta, Georgia, United States
› Author Affiliations
Further Information

Publication History

Publication Date:
06 June 2019 (online)

Abstract

Objective This study measured the in vivo temperature of prepared root canal walls during various stages of treatment prior to endodontic postcementation.

Materials and Methods One tooth each from five patients requiring endodontic treatment received conventional gutta-percha obturation. The coronal 4 mm of gutta-percha was removed by drilling and the canal wall temperature was measured. A sterile, saline rinse was applied, and another temperature value was recorded. Paper points were placed, and the wall temperature was recorded. A standardized period of 1.5 minute passed, simulating time needed to mix and place the resin cement and post (no resin was placed), after which the final wall temperature was obtained. The tooth was temporized and scheduled for prosthetic reconstruction. A one-way repeated measure analysis of variance (with Tukey's post hoc test) was performed among mean temperature values for each treatment stage (preset α 0.05).

Results Significant temperature differences were found among the treatment stages. Canal space drilling yielded the highest temperature (35.5 ± 0.8°C), while the lowest was obtained after saline rinsing (34.0 ± 0.9°C). The temperature of prepared root canal wall prior to postplacement (34.9 ± 1.2°C) and following paper point drying (34.8 ± 1.1°C) presented intermediate results, with no statistical difference between them.

Conclusions This study suggested that root canal wall temperature varied during various stages of preparation prior to endodontic post.

 
  • References

  • 1 Jurcak JJ, Weller RN, Kulild JC, Donley DL. In vitro intracanal temperatures produced during warm lateral condensation of gutta-percha. J Endod 1992; 18 (01) 1-3
  • 2 Gokturk H, Ozkocak I, Taskan MM, Aytac F, Karaarslan ES. In vitro evaluation of temperature rise during different post space preparations. Eur J Dent 2015; 9 (04) 535-541
  • 3 Saskalauskaite E, Tam LE, McComb D. Flexural strength, elastic modulus, and pH profile of self-etch resin luting cements. J Prosthodont 2008; 17 (04) 262-268
  • 4 Davis P, Melo LS, Foxton RM. et al. Flexural strength of glass fibre-reinforced posts bonded to dual-cure composite resin cements. Eur J Oral Sci 2010; 118 (02) 197-201
  • 5 Nakamura T, Wakabayashi K, Kinuta S, Nishida H, Miyamae M, Yatani H. Mechanical properties of new self-adhesive resin-based cement. J Prosthodont Res 2010; 54 (02) 59-64
  • 6 Aksornmuang J, Nakajima M, Senawongse P, Tagami J. Effects of C-factor and resin volume on the bonding to root canal with and without fibre post insertion. J Dent 2011; 39 (06) 422-429
  • 7 Aguiar TR, André CB, Ambrosano GM, Giannini M. The effect of light exposure on water sorption and solubility of self-adhesive resin cements. Int Sch Res Notices 2014; 2014: 610452
  • 8 Reza F, Ibrahim NS. Effect of ultraviolet light irradiation on bond strength of fiber post: Evaluation of surface characteristic and bonded area of fiber post with resin cement. Eur J Dent 2015; 9 (01) 74-79
  • 9 Haralur SB, Alasabi ANA, Al Qahtani SAA, Alqahtani SMS. Influence of irrigating agents on fiber postpush-out bond strength to radicular dentin sections with the different adhesive system. Eur J Dent 2017; 11 (03) 380-384
  • 10 Rueggeberg FA, Daronch M, Browning WD, DE Goes MF. In vivo temperature measurement: tooth preparation and restoration with preheated resin composite. J Esthet Restor Dent 2010; 22 (05) 314-322
  • 11 Price RB, Whalen JM, Price TB, Felix CM, Fahey J. The effect of specimen temperature on the polymerization of a resin-composite. Dent Mater 2011; 27 (10) 983-989
  • 12 Kitzmüller K, Graf A, Watts D, Schedle A. Setting kinetics and shrinkage of self-adhesive resin cements depend on cure-mode and temperature. Dent Mater 2011; 27 (06) 544-551
  • 13 Lin-Gibson S, Landis FA, Drzal PL. Combinatorial investigation of the structure-properties characterization of photopolymerized dimethacrylate networks. Biomaterials 2006; 27 (09) 1711-1717
  • 14 Guldener KA, Lanzrein CL, Siegrist Guldener BE, Lang NP, Ramseier CA, Salvi GE. Long-term clinical outcomes of endodontically treated teeth restored with or without fiber post-retained single-unit restorations. J Endod 2017; 43 (02) 188-193
  • 15 Radovic I, Corciolani G, Magni E. et al. Light transmission through fiber post: the effect on adhesion, elastic modulus and hardness of dual-cure resin cement. Dent Mater 2009; 25 (07) 837-844
  • 16 Sarkis-Onofre R, Skupien JA, Cenci MS, Moraes RR, Pereira-Cenci T. The role of resin cement on bond strength of glass-fiber posts luted into root canals: a systematic review and meta-analysis of in vitro studies. Oper Dent 2014; 39 (01) E31-E44
  • 17 Oskoee SS, Bahari M, Kimyai S, Asgary S, Katebi K. Push-out bond strength of fiber posts to intraradicular dentin using multimode adhesive system. J Endod 2016; 42 (12) 1794-1798
  • 18 Saini P, Kaur S, Bindu K, Kaur J. Effect of controlled room temperature on oral and axillary body temperature among healthy young people. Nurs Midwifery Res J 2014; 10: 166-174
  • 19 Dakappa PH, Mahabala C. Analysis of long-term temperature variations in the human body. Crit Rev Biomed Eng 2015; 43 (05) (06) 385-399
  • 20 Yoon MJ, Lee SJ, Kim E, Park SH. Doppler ultrasound to detect pulpal blood flow changes during local anaesthesia. Int Endod J 2012; 45 (01) 83-87
  • 21 Jafarzadeh H. Laser Doppler flowmetry in endodontics: a review. Int Endod J 2009; 42 (06) 476-490