CC BY 4.0 · Aorta (Stamford) 2019; 07(01): 029-032
DOI: 10.1055/s-0039-1687864
How I Do It
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve

Michele Antonello
1   Department of Cardiac, Thoracic and Vascular Sciences, Vascular and Endovascular Surgery Clinic, School of Medicine, Padova University, Padova, Italy
,
Augusto D'Onofrio
2   Division of Cardiac Surgery, Department of Cardiac, Thoracic and Vascular Sciences, School of Medicine, Padova University, Padova, Italy
,
Marco Zavatta
1   Department of Cardiac, Thoracic and Vascular Sciences, Vascular and Endovascular Surgery Clinic, School of Medicine, Padova University, Padova, Italy
,
Giambattista Isabella
3   Division of Cardiology, Department of Cardiac, Thoracic and Vascular Sciences, School of Medicine, Padova University, Padova, Italy
,
Carlo Maturi
1   Department of Cardiac, Thoracic and Vascular Sciences, Vascular and Endovascular Surgery Clinic, School of Medicine, Padova University, Padova, Italy
,
Michele Piazza
1   Department of Cardiac, Thoracic and Vascular Sciences, Vascular and Endovascular Surgery Clinic, School of Medicine, Padova University, Padova, Italy
,
Gino Gerosa
2   Division of Cardiac Surgery, Department of Cardiac, Thoracic and Vascular Sciences, School of Medicine, Padova University, Padova, Italy
› Author Affiliations
Funding None.
Further Information

Publication History

11 September 2017

28 February 2019

Publication Date:
22 July 2019 (online)

Abstract

The authors describe the transapical deployment of a thoracic endograft to exclude a saphenous vein graft proximal anastomotic pseudoaneurysm following coronary artery bypass grafting (CABG) in a 63-year-old male with a prosthetic aortic valve. A standard thoracic endograft has been deployed via transapical access after percutaneous transluminal coronary angioplasty of the native vessel perfused by the patent CABG. The procedure was uneventful; an 8-month computed tomography scan showed complete exclusion of the pseudoaneurysm with patency of supra-aortic trunks.

 
  • References

  • 1 Narita H, Komori K, Usui A. , et al. Postoperative outcomes of hybrid repair in the treatment of aortic arch aneurysms. Ann Vasc Surg 2016; 34: 55-61
  • 2 Tsilimparis N, Debus ES, Oderich GS. , et al. International experience with endovascular therapy of the ascending aorta with a dedicated endograft. J Vasc Surg 2016; 63 (06) 1476-1482
  • 3 Keon WJ, Bédard P, Akyurekli Y, Brais M. Causes of death in aortocoronary bypass surgery: experience with 1,000 patients. Ann Thorac Surg 1977; 23 (04) 357-360
  • 4 Rayan SS, Vega JD, Shanewise JS, Kong LS, Chaikof EL, Milner R. Repair of mycotic aortic pseudoaneurysm with a stent graft using transesophageal echocardiography. J Vasc Surg 2004; 40 (03) 567-570
  • 5 Ziegelmueller JA, Lange R, Bleiziffer S. Access and closure of the left ventricular apex: state of play. J Thorac Dis 2015; 7 (09) 1548-1555
  • 6 MacDonald S, Cheung A, Sidhu R, Rheaume P, Grenon SM, Clement J. Endovascular aortic aneurysm repair via the left ventricular apex of a beating heart. J Vasc Surg 2009; 49 (03) 759-762
  • 7 Deriu G, Grego F, Frigatti P. , et al. Unusual inflow sources and device introduction sites in aortic arch debranching. J Cardiovasc Surg (Torino) 2012; 53 (02) 143-151
  • 8 Szeto WY, Moser WG, Desai ND. , et al. Transapical deployment of endovascular thoracic aortic stent graft for an ascending aortic pseudoaneurysm. Ann Thorac Surg 2010; 89 (02) 616-618