Subscribe to RSS
Please copy the URL and add it into your RSS Feed Reader.
https://www.thieme-connect.de/rss/thieme/en/10.1055-s-00035023.xml
Vet Comp Orthop Traumatol 1988; 01(01): 38-43
DOI: 10.1055/s-0038-1633161
DOI: 10.1055/s-0038-1633161
Short Communication
An Animal Model for the Implantation of a Bone Liner in the Flexible Implant Arthroplasty
Further Information
Publication History
Publication Date:
22 February 2018 (online)
A retrospective study of silicone elastomer implants used clinically as a flexible implant in the metacarpophalangeal (MP) and proximal interphalangeal (PIP) joints in humans indicated a 7.6% implant fracture failure rate. Implant fractures appeared to occur from tear propagation due to damage resulting from the impingement of the sharp bone edges upon the implant’s surface. A protective synthetic bone liner was devised to reduce in vivo damage and prevent implant failures. The rabbit stifle was used as the animal model for the human metacarpophalangeal and proximal interphalangeal joint and 73 implant arthroplasties were successfully performed.
-
References
- 1 Nalban Dian R M, Swanson A B, Maupin B K. Long-term silicone implant arthroplasty: Implications of animal and human autopsy findings. J Am Med Assoc 1983; 250 (09) 1195-8.
- 2 Swanson A B. Flexible implant resection arthroplasty. Hand 1972; 4: 119-34.
- 3 Swanson A B. Flexible implant arthroplasty in the hand. Clin Plast Surg 1976; 3 (01) 141-57.
- 4 Swanson A B. Flexible implant arthroplasty for arthritic finger joints: rationale technique and results of treatment. J Bone Joint Surg 1972; 54A: 435-55.
- 5 Swanson A B. Finger joint replacement by silicone rubber implants and the concept of implant fixation by encapsulation. Ann Rheum Dis 1969; 28: 47-55.
- 6 Swanson A B, deGroot Swanson G. Implant arthroplasty in the hand and wrist. An update. Ann Chir Main 1984; 3 (01) 43-57.
- 7 Swanson A B. Implant arthroplasty in the hand and upper extremity and its future. Surg Clin North Am 1981; 61 (02) 369-82.
- 8 Swanson A B, deGroot Swanson G, Frisch E E. Flexible (silicone) implant arthroplasty in small joints of the extremities: Concepts, physical and biological considerations, experimental and clinical results. In: Rubin L R. (ed). Biomaterials in Reconstructive Surgery. St. Louis: C V Mosby Co; 1983: 595-623.
- 9 Carmen R, Mutha S C. Lipid absorption by silicone rubber heart valve poppets – in vivo and in vitro results. J Biomed Mater Res 1972; 6: 327-46.
- 10 Chin H P, Harrison E C, Blankenhorn D H, Moacann J. Lipids in silicone rubber valve prothesis after human implantation. Am J Clin Path 1971; 33: 545-9.
- 11 Swanson A B, Meester W D, Swanson G G. et al. Durability of silicone implants – an in vivo study. Orthop Clin North Am 1973; 4: 1097-112.
- 12 Weightman B, Simon S, Rose R. et al. Environmental fatigue testing of silastic finger joint protheses. J Biomed Mater Res 1972; 3: 15-24.
- 13 Bjelle A O, Nilsson B E. The relationship between radiological changes and osteoporosis of the hand in rheumatoid arthritis. Arthr Ano Rheumat 1971; 14: 646-9.
- 14 Duncan H, Frost H M, Villanusua A R, Sigler J W. The osteoporosis of rheumatoid arthritis. Arthr Rheumat 1965; 8: 843-54.
- 15 Weigand A J, Banks B A. Ion-beam-sputter modification of the surface morphology of biological implants. J Vac Sci Technol. 1977; 14: 326-31.
- 16 Davis N L, Malinin T I. Rabbit intubation and halothane anesthesia. Lab Anim Sci 1974; 27: 617-21.