Subscribe to RSS
DOI: 10.1055/s-0038-1632548
Pullout Strength of Screws in Foal Third Metacarpal Bone after Overdrilling a 4.5 mm Hole
Publication History
Received:04 December 1997
Accepted:20 January 1998
Publication Date:
10 February 2018 (online)
Summary
The purpose of the study was to determine and to compare the in vitro pullout strength of 5.5 mm cortical versus 6.5 mm cancellous bone screws inserted in the diaphysis and metaphysis of foal third metacarpal (MCIII) bones in threaded 4.5 mm cortical bone screw insertion holes that were then overdrilled with a 4.5 mm drill bit. This information is relevant to the selection of a replacement screw if a 4.5 mm cortical screw is stripped during orthopaedic surgery.
In vitro pullout tests were performed in two independent cadaver studies, each consisting of 12 foal MCIII bones. Two 4.5 mm cortical screws were placed either in the mid-diaphysis (study 1) or distal metaphysis (study 2) of MCIII bones. The holes were then overdrilled with a 4.5 mm bit and had either a 5.5 mm cortical or a 6.5 mm cancellous screw inserted; screw pullout tests were performed at a rate of 0.04 mm/s until screw or bone failure occurred.
The bone failed in all of the tests in the diaphyseal and metaphyseal bone. The holding power for 6.5 mm cancellous screws was significantly (p <0.05) greater than for 5.5 mm cortical screws in both the diaphysis and metaphysis. There was not any difference in the holding power of screws in either the diaphysis or the metaphysis between proximal and distal screw holes.
If a 4.5 mm cortical bone screw strips in MCIII diaphyseal or metaphyseal bone of foals, a 6.5 mm cancellous screw would provide greater holding power than a 5.5 mm cortical screw.
In order to provide information regarding selection of a replacement screw if a 4.5 mm cortical screw is stripped, the in vitro pullout strength was determined for 5.5 mm cortical and 6.5 mm cancellous screws inserted in third metacarpal diaphyseal and metaphyseal bone of foals in which threaded 4.5 mm cortical bone screw insertion holes had been overdrilled with a 4.5 mm bit. The holding power of the 6.5 mm cancellous screw was significantly greater than the 5.5 mm cortical screw in both the diaphysis and metaphysis of foal third metacarpal bone. Thus, it appears that if a 4.5 mm cortical screw is stripped during orthopaedic surgery in foals, a 6.5 mm cancellous screw would provide superior holding power.
-
REFERENCES
- 1 Auer J A. Principles of fracture treatment. In Equine Surgery Auer JA. (ed). Philadelphia: W. B.: Saunders Co; 1991: 812-33.
- 2 Boyd CL, Bynum D, Ray DR. et al. In vitro evaluation of bone fasteners. Southwestern Vet 1970; 23: 279-81.
- 3 Decoster TA, Heetderks DB, Dowey JS. et al. Optimizing bone screw pullout force. J Orthop Trauma 1990; 4: 169-74.
- 4 Fackelman GE, Nunamaker DM. General techniques and biomechanics of internal fixation. In Manual of Internal Fixation in the Horse.. Fackelman GE, Nunamaker DM. (eds). New York: Springer-Verlag; 1982: 8-24.
- 5 Gantous A, Phillips JH. The effects of varying pilot hole size on the holding power of miniscrews and microscrews. Plast Reconst Surg 1995; 95: 1165-9.
- 6 Gillis PJ, Zardiackas DL. Holding power of cortical screws after power tapping and hand tapping. Vet Surg 1992; 21: 362-6.
- 7 Hanson PD, Markel MD. Radiographic geometric variation of equine long bones. Am J Vet Res 1994; 55: 1120-227.
- 8 Mcllwraith CW, Turner AS. Orthopedic surgery; lag screw fixation principles. In Equine Surgery, Advanced Techniques.. Mcllwraith CW, Turner AS. (eds). Philadelphia: Lea & Febiger; 1987: 53-5.
- 9 Nunamaker DN, Butterweck DM, Provost MT. Some geometric properties of the third metacarpal bone: A comparison between the Thoroughbred and Standardbred racehorse. J Biomech 1989; 22: 129-34.
- 10 Sedrish SA, Moore RM, Kelly K. et al. Invitro pullout strength of screws inserted in adult equine third metacarpal bones after overdrilling a 4.5 mm threaded insertion hole. Vet Surg 1998; 27: 143-9.
- 11 Yovich JV, Turner AS, Smith FW. Holding power of orthopedic screws in equine third metacarpal and metatarsal bones part 1: Foal bone. Vet Surg 1985; 14: 221-9.
- 12 Yovich JV, Turner AS, Smith FW. Holding power of orthopedic screws in equine third metacarpal and metatarsal bones Part II: Adult horse bone. Vet Surg 1985; 14: 230-4.
- 13 Yovich JV, Turner AS, Smith FW. Holding power of orthopedic screws; Comparison of self-tapped and pre-tapped screws in foal bones. Vet Surg 1986; 15: 55-9.