RSS-Feed abonnieren
DOI: 10.1055/s-0038-1626687
Nerve Repair with Nerve Conduits: Problems, Solutions, and Future Directions
Funding Partially supported by research grants from British Council's UKIERI Trilateral research partnerships 2011 (Yang, Kundu, and Li) and Department of Defense CDMRP (US) grant OR120157P1 (Smith and Li).Publikationsverlauf
Received: 07. September 2017
Accepted: 02. Januar 2018
Publikationsdatum:
20. März 2018 (online)
Abstract
Nerve conduits are becoming increasingly popular for the repair of peripheral nerve injuries. Their ease of application and lack of donor site morbidity make them an attractive option for nerve repair in many situations. Today, there are many different conduits to choose in different sizes and materials, giving the reconstructive surgeon many options for any given clinical problem. However, to properly utilize these unique reconstructive tools, the peripheral nerve surgeon must be familiar not only with their standard indications but also with their functional limitations. In this review, the authors identify the common applications of nerve conduits, expected results, and shortcomings of current techniques. Furthermore, future directions for nerve conduit use are identified.
-
References
- 1 Sachanandani NF, Pothula A, Tung TH. Nerve gaps. Plast Reconstr Surg 2014; 133 (02) 313-319
- 2 Bruyns CN, Jaquet JB, Schreuders TA, Kalmijn S, Kuypers PD, Hovius SE. Predictors for return to work in patients with median and ulnar nerve injuries. J Hand Surg Am 2003; 28 (01) 28-34
- 3 Jaquet JB, Luijsterburg AJ, Kalmijn S, Kuypers PD, Hofman A, Hovius SE. Median, ulnar, and combined median-ulnar nerve injuries: functional outcome and return to productivity. J Trauma 2001; 51 (04) 687-692
- 4 Siemionow M, Brzezicki G. Chapter 8: current techniques and concepts in peripheral nerve repair. Int Rev Neurobiol 2009; 87: 141-172
- 5 Lee SK, Wolfe SW. Peripheral nerve injury and repair. J Am Acad Orthop Surg 2000; 8 (04) 243-252
- 6 Griffin JW, Hogan MV, Chhabra AB, Deal DN. Peripheral nerve repair and reconstruction. J Bone Joint Surg Am 2013; 95 (23) 2144-2151
- 7 Li R, Liu Z, Pan Y, Chen L, Zhang Z, Lu L. Peripheral nerve injuries treatment: a systematic review. Cell Biochem Biophys 2014; 68 (03) 449-454
- 8 Kehoe S, Zhang XF, Boyd D. FDA approved guidance conduits and wraps for peripheral nerve injury: a review of materials and efficacy. Injury 2012; 43 (05) 553-572
- 9 Deumens R, Bozkurt A, Meek MF. et al. Repairing injured peripheral nerves: Bridging the gap. Prog Neurobiol 2010; 92 (03) 245-276
- 10 Ichihara S, Inada Y, Nakamura T. Artificial nerve tubes and their application for repair of peripheral nerve injury: an update of current concepts. Injury 2008; 39 Suppl (04) 29-39
- 11 Johnson EO, Soucacos PN. Nerve repair: experimental and clinical evaluation of biodegradable artificial nerve guides. Injury 2008; 39 (03) Suppl 3 S30-S36
- 12 Johnson EO, Zoubos AB, Soucacos PN. Regeneration and repair of peripheral nerves. Injury 2005; 36 (04) Suppl 4 S24-S29
- 13 Gerth DJ, Tashiro J, Thaller SR. Clinical outcomes for Conduits and Scaffolds in peripheral nerve repair. World J Clin Cases 2015; 3 (02) 141-147
- 14 Mackinnon SE, Hudson AR, Falk RE, Kline D, Hunter D. Peripheral nerve allograft: an assessment of regeneration across pretreated nerve allografts. Neurosurgery 1984; 15 (05) 690-693
- 15 Aebischer P, Guénard V, Winn SR, Valentini RF, Galletti PM. Blind-ended semipermeable guidance channels support peripheral nerve regeneration in the absence of a distal nerve stump. Brain Res 1988; 454 (01) (02) 179-187
- 16 Hudson TW, Evans GR, Schmidt CE. Engineering strategies for peripheral nerve repair. Clin Plast Surg 1999; 26 (04) 617-628
- 17 Kokai LE, Lin YC, Oyster NM, Marra KG. Diffusion of soluble factors through degradable polymer nerve guides: controlling manufacturing parameters. Acta Biomater 2009; 5 (07) 2540-2550
- 18 de Ruiter GC, Malessy MJ, Yaszemski MJ, Windebank AJ, Spinner RJ. Designing ideal conduits for peripheral nerve repair. Neurosurg Focus 2009; 26 (02) E5
- 19 de Ruiter GC, Spinner RJ, Yaszemski MJ, Windebank AJ, Malessy MJ. Nerve tubes for peripheral nerve repair. Neurosurg Clin N Am 2009; 20 (01) 91-105
- 20 Bellamkonda RV. Peripheral nerve regeneration: an opinion on channels, scaffolds and anisotropy. Biomaterials 2006; 27 (19) 3515-3518
- 21 Lietz M, Dreesmann L, Hoss M, Oberhoffner S, Schlosshauer B. Neuro tissue engineering of glial nerve guides and the impact of different cell types. Biomaterials 2006; 27 (08) 1425-1436
- 22 Griffith LG. Emerging design principles in biomaterials and scaffolds for tissue engineering. Ann N Y Acad Sci 2002; 961: 83-95
- 23 Jiang X, Lim SH, Mao HQ, Chew SY. Current applications and future perspectives of artificial nerve conduits. Exp Neurol 2010; 223 (01) 86-101
- 24 Mackinnon SE, Dellon AL. Clinical nerve reconstruction with a bioabsorbable polyglycolic acid tube. Plast Reconstr Surg 1990; 85 (03) 419-424
- 25 Rinker B, Liau JY. A prospective randomized study comparing woven polyglycolic acid and autogenous vein conduits for reconstruction of digital nerve gaps. J Hand Surg Am 2011; 36 (05) 775-781
- 26 Weber RA, Breidenbach WC, Brown RE, Jabaley ME, Mass DP. A randomized prospective study of polyglycolic acid conduits for digital nerve reconstruction in humans. Plast Reconstr Surg 2000; 106 (05) 1036-1045
- 27 Bushnell BD, McWilliams AD, Whitener GB, Messer TM. Early clinical experience with collagen nerve tubes in digital nerve repair. J Hand Surg Am 2008; 33 (07) 1081-1087
- 28 Taras JS, Jacoby SM, Lincoski CJ. Reconstruction of digital nerves with collagen conduits. J Hand Surg Am 2011; 36 (09) 1441-1446
- 29 Lohmeyer JA, Kern Y, Schmauss D. et al. Prospective clinical study on digital nerve repair with collagen nerve conduits and review of literature. J Reconstr Microsurg 2014; 30 (04) 227-234
- 30 Haug A, Bartels A, Kotas J, Kunesch E. Sensory recovery 1 year after bridging digital nerve defects with collagen tubes. J Hand Surg Am 2013; 38 (01) 90-97
- 31 Moore AM, Kasukurthi R, Magill CK, Farhadi HF, Borschel GH, Mackinnon SE. Limitations of conduits in peripheral nerve repairs. Hand (NY) 2009; 4 (02) 180-186
- 32 Lundborg G, Dahlin LB, Danielsen N. Ulnar nerve repair by the silicone chamber technique. Case report. Scand J Plast Reconstr Surg Hand Surg 1991; 25 (01) 79-82
- 33 Lundborg G, Rosén B, Dahlin L, Holmberg J, Rosén I. Tubular repair of the median or ulnar nerve in the human forearm: a 5-year follow-up. J Hand Surg [Br] 2004; 29 (02) 100-107
- 34 Donoghoe N, Rosson GD, Dellon AL. Reconstruction of the human median nerve in the forearm with the Neurotube. Microsurgery 2007; 27 (07) 595-600
- 35 Hung V, Dellon AL. Reconstruction of a 4-cm human median nerve gap by including an autogenous nerve slice in a bioabsorbable nerve conduit: case report. J Hand Surg Am 2008; 33 (03) 313-315
- 36 Dienstknecht T, Klein S, Vykoukal J. et al. Type I collagen nerve conduits for median nerve repairs in the forearm. J Hand Surg Am 2013; 38 (06) 1119-1124
- 37 Klein S, Vykoukal J, Felthaus O, Dienstknecht T, Prantl L. Collagen type I conduits for the regeneration of nerve defects. Materials (Basel) 2016; 9 (04) 219
- 38 Jenq CB, Coggeshall RE. Permeable tubes increase the length of the gap that regenerating axons can span. Brain Res 1987; 408 (01) (02) 239-242
- 39 Heath CA, Rutkowski GE. The development of bioartificial nerve grafts for peripheral-nerve regeneration. Trends Biotechnol 1998; 16 (04) 163-168
- 40 Lee JY, Giusti G, Friedrich PF. et al. The effect of collagen nerve conduits filled with collagen-glycosaminoglycan matrix on peripheral motor nerve regeneration in a rat model. J Bone Joint Surg Am 2012; 94 (22) 2084-2091
- 41 Sahakyants T, Lee JY, Friedrich PF, Bishop AT, Shin AY. Return of motor function after repair of a 3-cm gap in a rabbit peroneal nerve: a comparison of autograft, collagen conduit, and conduit filled with collagen-GAG matrix. J Bone Joint Surg Am 2013; 95 (21) 1952-1958
- 42 Pace LA, Plate JF, Mannava S. et al. A human hair keratin hydrogel scaffold enhances median nerve regeneration in nonhuman primates: an electrophysiological and histological study. Tissue Eng Part A 2014; 20 (03) (04) 507-517
- 43 Yang Y, Yuan X, Ding F. et al. Repair of rat sciatic nerve gap by a silk fibroin-based scaffold added with bone marrow mesenchymal stem cells. Tissue Eng Part A 2011; 17 (17) (18) 2231-2244
- 44 Sun B, Zhou Z, Wu T. et al. Development of nanofiber sponges-containing nerve guidance conduit for peripheral nerve regeneration in vivo. ACS Appl Mater Interfaces 2017; 9 (32) 26684-26696
- 45 Hundepool CA, Nijhuis TH, Mohseny B, Selles RW, Hovius SE. The effect of stem cells in bridging peripheral nerve defects: a meta-analysis. J Neurosurg 2014; 121 (01) 195-209
- 46 Fu KY, Dai LG, Chiu IM, Chen JR, Hsu SH. Sciatic nerve regeneration by microporous nerve conduits seeded with glial cell line-derived neurotrophic factor or brain-derived neurotrophic factor gene transfected neural stem cells. Artif Organs 2011; 35 (04) 363-372
- 47 Sivak WN, White JD, Bliley JM. et al. Delivery of chondroitinase ABC and glial cell line-derived neurotrophic factor from silk fibroin conduits enhances peripheral nerve regeneration. J Tissue Eng Regen Med 2017; 11 (03) 733-742
- 48 de Boer R, Borntraeger A, Knight AM. et al. Short- and long-term peripheral nerve regeneration using a poly-lactic-co-glycolic-acid scaffold containing nerve growth factor and glial cell line-derived neurotrophic factor releasing microspheres. J Biomed Mater Res A 2012; 100 (08) 2139-2146
- 49 Gu X, Ding F, Williams DF. Neural tissue engineering options for peripheral nerve regeneration. Biomaterials 2014; 35 (24) 6143-6156
- 50 Apel PJ, Ma J, Callahan M. et al. Effect of locally delivered IGF-1 on nerve regeneration during aging: an experimental study in rats. Muscle Nerve 2010; 41 (03) 335-341
- 51 Manoli T, Schulz L, Stahl S, Jaminet P, Schaller HE. Evaluation of sensory recovery after reconstruction of digital nerves of the hand using muscle-in-vein conduits in comparison to nerve suture or nerve autografting. Microsurgery 2014; 34 (08) 608-615
- 52 Sabongi RG, Fernandes M, Dos Santos JB. Peripheral nerve regeneration with conduits: use of vein tubes. Neural Regen Res 2015; 10 (04) 529-533
- 53 Paprottka FJ, Wolf P, Harder Y. et al. Sensory recovery outcome after digital nerve repair in relation to different reconstructive techniques: meta-analysis and systematic review. Plast Surg Int 2013; 2013 704589
- 54 Chou KH, Papadimitriou NG, Sarris I, Sotereanos DG. Neovascularization and other histopathologic findings in an autogenous saphenous vein wrap used for recalcitrant carpal tunnel syndrome: a case report. J Hand Surg Am 2003; 28 (02) 262-266
- 55 Taras JS, Amin N, Patel N, McCabe LA. Allograft reconstruction for digital nerve loss. J Hand Surg Am 2013; 38 (10) 1965-1971
- 56 Karabekmez FE, Duymaz A, Moran SL. Early clinical outcomes with the use of decellularized nerve allograft for repair of sensory defects within the hand. Hand (NY) 2009; 4 (03) 245-249
- 57 Cho MS, Rinker BD, Weber RV. et al. Functional outcome following nerve repair in the upper extremity using processed nerve allograft. J Hand Surg Am 2012; 37 (11) 2340-2349
- 58 Rinker BD, Ingari JV, Greenberg JA, Thayer WP, Safa B, Buncke GM. Outcomes of short-gap sensory nerve injuries reconstructed with processed nerve allografts from a multicenter registry study. J Reconstr Microsurg 2015; 31 (05) 384-390
- 59 Rinker B, Zoldos J, Weber RV. et al. Use of processed nerve allografts to repair nerve injuries greater than 25 mm in the hand. Ann Plast Surg 2017; 78 (6S, Suppl 5) S292-S295