Suggestions for an appropriate methodological approach for the validation of an evacuated blood collection tube made in plastic material including the effect of age

Karine Foucher
,
Pierre Toulon
,
Jean-François Schved
,
Benoit Polack
Further Information

Publication History

Received 04 November 2003

Accepted after revision 23 December 2003

Publication Date:
08 December 2017 (online)

 

 
  • References

  • 1 Polack B, Schved J-F, Boneu B. Preanalytical recommendations of the “Groupe d’Etudes sur l’Hemostase et la Thrombose” (GEHT) for venous blood testing in hemostasis laboratories. Haemostasis 2001; 31: 61-8.
  • 2 Postaire E. Les matières plastiques à usage pharmaceutique. 2ème édition. Editions Mèdi-cales Internationales. 1991
  • 3 ISO 6710:1995(F). Single use containers for venous blood collection. Version. 1996-02 ISO Editions 1996.
  • 4 Adcock DM, Kressin DC, Marlar RA. Effect of 3,2% vs 3,8% sodium citrate concentration on routine coagulation testing. Am J Clin Pathol 1997; 107: 105-10.
  • 5 Adcock DM, Kressin DC, Marlar RA. Minimum specimen volume requirements for routine coagulation testing - Dependance on citrate concentration. Am J Clin Pathol 1998; 109: 595-9.
  • 6 Bland JM, Altaian DJ. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 01: 307-10.
  • 7 Polack B, Vigier J-R. Stability of prothrombin time and the impact of container material. Clin Lab Haem 2000; 22: 58.
  • 8 Biron-Andréani C, Mallol C, Séguret F. et al.. Plastic versus siliconized glass tubes: evaluation in current laboratory practice. Thromb Haemost 2000; 83: 801.
  • 9 D’Angelo G, Villa C. Measurement of prothrombin time in patients on oral anticoagulant therapy: effect of 2 different evacuated tubes. Haematologica 1999; 84: 656-72.
  • 10 Van Den Besselaar AMPH. A comparison of 2 sodium citrate concentrations in two evacuated blood collection systems for prothrombin time ands ISI determination. Thromb Haemost 2000; 84: 664-7.
  • 11 Van Den Besselaar AMPH. Different sensitivities of various thromboplastins to two blood collection systems for monitoring oral anticoagulant therapy. Thromb Haemost 1999; 82: 153-4.
  • 12 Van Den Besselaar AMPH. Effect of evacuated blood collection tube on thromboplastins calibration. Thromb Haemost 1998; 79: 1062-3.
  • 13 Tripodi A, Chantarangkul V, Bressi C. et al.. How to evaluate the influence of blood collection systems on the ISI. Protocol applied to 2 new evacuated tubes and eight coagulome ter/thromboplastin combinations. Thromb Res 2003; 108: 85-9.
  • 14 Tripodi A, Chantarangkul V, Bressi C. et al.. International sensitivity index calibration of the near-patient testing prothrombin time monitor, ProTime. Am J Clin Pathol 2003; 119: 241-5.